The Nuclear Fast Red solution can be prepared following a specific protocol with catalog number N8002It is recommended to use aluminum sulfate anhydrous over the various hydrated forms of aluminum sulfate. The hydrated forms of aluminum sulfate may contain 30 to 50% less aluminum sulfate per gram of solid, potentially leading to shorter solution stability. The prepared solution is suitable for iron staining and other special stain procedures that require a non-blue nuclear counterstain.
Vybrat velikost
| Vám/Skladová položka | Dostupnost | Cena |
|---|---|---|
100 mL | Obraťte se na zákaznický servis a vyžádejte si informaci o dostupnosti. | 2 380,00 Kč 1 666,00 Kč |
O této položce
1 666,00 Kč
Ceníková cena2 380,00 KčUložit 30 %form
solution
Quality Segment
shelf life
Expiry date on the label
IVD
for in vitro diagnostic use
application(s)
hematology
histology
storage temp.
room temp
SMILES string
[Na+].Nc1c(O)c(c(O)c2C(=O)c3ccccc3C(=O)c12)S([O-])(=O)=O
InChI
1S/C14H9NO7S.Na/c15-9-7-8(12(18)14(13(9)19)23(20,21)22)11(17)6-4-2-1-3-5(6)10(7)16;/h1-4,18-19H,15H2,(H,20,21,22);/q;+1/p-1
InChI key
IFSXZLJQEKGQAF-UHFFFAOYSA-M
General description
Application
- In the dual-beam (FIB (focused ion beam)/SEM (scanning electron microscopy)) analysis of intracellular MNPs (magnetic nanoparticles) distribution.[1]
- As a counterstain in LacZ tissue histological analysis, and in extracellular matrix proteoglycan staining.
- In situ hybridization.
Other Notes
1 of 1
Tato položka | |||
|---|---|---|---|
| form solution | form powder | form powder | form solution |
| application(s) hematology | application(s) diagnostic assay manufacturing | application(s) diagnostic assay manufacturing | application(s) hematology |
| storage temp. room temp | storage temp. room temp | storage temp. room temp | storage temp. room temp |
| IVD for in vitro diagnostic use | IVD - | IVD - | IVD for in vitro diagnostic use |
| shelf life Expiry date on the label | shelf life - | shelf life - | shelf life Expiry date on the label |
| Quality Level 500 | Quality Level 200 | Quality Level 100 | Quality Level 500 |
signalword
Danger
hcodes
Hazard Classifications
Eye Dam. 1 - Met. Corr. 1
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type ABEK (EN14387) respirator filter
Skladovací třída
10 - Combustible liquids
Vyberte jednu z posledních verzí:
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
-
looking for instruction to prepare a working solution of nuclear fast red stain using 60700. should Aluminum Sulfate be added? If so, can Aluminum Sulphate hydrate be used? need to use it as a counter stain for my iron staining.
1 answer-
Helpful?
-