Vybrat velikost
| Velikost balení | Skladová položka | Dostupnost | Cena |
|---|---|---|---|
| 1 ea | Očekávané datum odeslání18. května 2026odAreál Kühne+Nagel spol. s r.o. | 205 300,00 Kč |
O této položce
205 300,00 Kč
Očekávané datum odeslání18. května 2026podrobné informace
Quality Level
material
TPE seal, composite regenerated cellulose (CRC) , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated)
feature
holdup volume 170 mL (in feed channel)
manufacturer/tradename
Pellicon®
parameter
30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C
technique(s)
analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)
H
3.8 cm (1.51 in.)
L
20.6 cm (8.1 in.)
W
17.8 cm (7 in.)
filtration area
1.14 m2
membrane area
1.14 m2
gravimetric extractables
≤1500 mg/m2
matrix
Ultracel® (Membrane)
pore size
30 kDa NMWCO
pH
2-13
General description
The Pellicon® 3 Cassette with Ultracel® Membrane is designed for the filtration of therapeutic proteins (such as monoclonal antibodies) and recombinant and non-recombinant proteins.
This P3C030C10 Pellicon® 3 ultrafiltration device features a pore size of 30 kDa NMWCO, a filtration area of 1.14 m2, a PLCTK membrane, and dimensions measuring 2.4 cm (H) x 17.8 cm (W) x 20.6 cm (L).
Features and Benefits
- Rugged & reliable – ideally suited for today′s more demanding filtration processes
- High performance – produces excellent resolution, yields and back-pressure resistance
- Optimum product recovery – thanks to proven membrane technology
- Void-free technology – leading-edge membranes resolve virtually any separation challenge
- Defect-free, superior adhesion – Ultracel®uses composite membranes cast on a microporous substrate
- Automated manufacturing – delivers unbeatable performance, consistency and reliability
- Easy installation & care – simple to install and maintain
Analysis Note
Other Notes
Legal Information
1 of 1
Tato položka | |||
|---|---|---|---|
| pore size 30 kDa NMWCO | pore size 10 kDa NMWCO | pore size 30 kDa NMWCO | pore size 30 kDa NMWCO |
| technique(s) analytical sample preparation: suitable, protein purification: suitable (concentration), buffer exchange: suitable | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) | technique(s) analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration) |
| filtration area 1.14 m2 | filtration area 1.14 m2 | filtration area 1.14 m2 | filtration area 0.11 m2 |
| matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) | matrix Ultracel® (Membrane) |
| material TPE seal, polypropylene screen, composite regenerated cellulose (CRC) , stainless steel cap (for end; polypropylene-encapsulated) | material TPE seal, composite regenerated cellulose (CRC) , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated) | material TPE seal, composite regenerated cellulose (CRC) , polypropylene screen, stainless steel cap (for end; polypropylene-encapsulated) | material TPE seal, composite regenerated cellulose (CRC) , polypropylene cap (for end), polypropylene screen |
| parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 40 psi max. transmembrane pressure at 4-50 °C, 80 psi max. transmembrane pressure at 4-40 °C, 4-6 L/min-m2 recirculation rate, 6.9 bar max. inlet pressure (100 psi) | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C | parameter 30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C |
Still not finding the right product?
Explore all of our products under Pellicon® 3 Cassette with Ultracel® Membrane
Skladovací třída
10 - Combustible liquids
wgk
WGK 2
Dodržování zásad SVP pomocí programu Emprove®
Urychlete kvalifikaci, zajistěte shodu s předpisy a ušetřete čas s nástrojem Emprove® Dossiers.
Poznámka: budete přeneseni na stránky EmproveSuite.com. Vaše uživatelské jméno a heslo jsou oddělené od stránek SigmaAldrich.com a mohou se lišit.
Zaregistrujte se zdarma a získejte přístup k Emprove® Dossiers během několika minut. Upgradujte svůj plán předplatného a odemkněte si pokročilý a přizpůsobený obsah v Emprove® Suite.
Nenašli jste, co jste hledali? Navštivte stránku nápovědy programu Emprove®..
Již tento produkt vlastníte?
Dokumenty související s produkty, které jste v minulosti zakoupili, byly za účelem usnadnění shromážděny ve vaší Knihovně dokumentů.
Sortimentní položky
What antibody drug conjugates are, how bioconjugates work, design considerations and ADC services for ADC manufacturing, including bioconjugation.
Raman spectroscopy is a powerful tool for in-line, real-time monitoring of the removal of solvents during the TFF step of ADC manufacturing.
This page provides an overview of USP <87>, <88>, and <1031>, compares bioreactivity testing, and describes the transition of our organization towards in vitro test methods.
Globální číslo obchodní položky
| Skladová položka | GTIN |
|---|---|
| P3C030C10 | 04053252313509 |

