1.15445
LiChrospher® HPTLC plates, Silica gel 60 F₂₅₄s
pkg of 25 plates, plate L × W 20 cm × 10 cm, glass support
Synonim(y):
High Performance TM=["LiChrospher"] TLC Plates
Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych
About This Item
Polecane produkty
Materiały
glass support
silica gel 60 matrix
Poziom jakości
Właściwości
binder Organic Polymer
fluorescent indicator
opakowanie
pkg of 25 plates
metody
thin layer chromatography (TLC): suitable
grubość warstwy
200 μm
płytka dł. × szer.
20 cm × 10 cm
wielkość cząstki
5-6 μm
wielkość porów
60 Å medium pore diameter
temp. przechowywania
2-30°C
Opis ogólny
25 Glass plates 20 x 10 cm
Unique HPTLC Lichrospher® plates are the first thin layer chromatography plates based on spherical silica particles. They offer the ultimate in thin layer chromatography performance and speed enabling high throughput analysis of complex samples.
Powiązanie
Replaces: 115445-1; 115445
Komentarz do analizy
Layer thickness: 170 - 190 µm
Deviation of layer thickness per plate: ≤ 20 µm
Chromatographic testings:
A) Colour test
hRf-values
- Violett 1, colour test, lipophile:
5 - 15
- Nitroechtblue, colour test, lipophile: 20 - 30
- Sico- Fettblue, colour test, lipophile: 50 - 60
separation number
- colourtest, lipophile:
≥ 10.0
B) Steroid test
hRf-values
- D-Aldosterone, steroid test:
5 - 15
- Cortisone, steroid test: 20 - 30
- Progesterone, steroid test: 45 - 57
separation number
- steroid test:
≥ 10.0
Typical value determined on a conditioned plate
Eluent A) Toluene (20% rel.humidity)
Eluent B) Ethyl acetate/Toluene (95+5 v/v; 20% rel.humidity)
Deviation of layer thickness per plate: ≤ 20 µm
Chromatographic testings:
A) Colour test
hRf-values
- Violett 1, colour test, lipophile:
5 - 15
- Nitroechtblue, colour test, lipophile: 20 - 30
- Sico- Fettblue, colour test, lipophile: 50 - 60
separation number
- colourtest, lipophile:
≥ 10.0
B) Steroid test
hRf-values
- D-Aldosterone, steroid test:
5 - 15
- Cortisone, steroid test: 20 - 30
- Progesterone, steroid test: 45 - 57
separation number
- steroid test:
≥ 10.0
Typical value determined on a conditioned plate
Eluent A) Toluene (20% rel.humidity)
Eluent B) Ethyl acetate/Toluene (95+5 v/v; 20% rel.humidity)
Informacje prawne
LiChrospher is a registered trademark of Merck KGaA, Darmstadt, Germany
This page may contain text that has been machine translated.
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej