Wybierz wielkość
| Gabaryty przesyłki | SKU | Dostępność | Cena netto |
|---|---|---|---|
| 1 pkg | Skontaktuj się z Obsługą Klienta, aby uzyskać informacje na temat dostępności | 4660,00 zł |
Informacje o tej pozycji
4660,00 zł
Nazwa produktu
Purospher® STAR RP-18 endcapped (2 µm) UHPLC Columns, L × I.D. 150 mm x 2.1 mm Hibar® HR UHPLC column
material
stainless steel column
Quality Level
agency
suitable for USP L1
product line
Purospher®
feature
endcapped
packaging
1 ea of
extent of labeling
17% Carbon loading
parameter
1000 bar pressure, 65 °C max. temp.
technique(s)
LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable, mass spectrometry (MS): suitable (High)
column L × I.D.
15 cm × 2.1 mm
matrix
fully porous particle
matrix active group
C18 (RP18), C18 bonding phase
particle size
2 μm
pore size
120 Å pore size
operating pH range
1.5-10.5
separation technique
reversed phase, supercritical fluid (SFC)
storage temp.
no temp limit
General description
Application
Features and Benefits
- Ultra-pure silica (99.999%) for excellent peak symmetry
- High separation efficiency
- Reproducible results from run-to-run and batch-to-batch
- Best all-round performance according to Tanaka
- Outstanding pH stability from pH 1.5 to 10.5
- No phase collapse when using highly aqueous mobile phases
- Good suitability for LC-MS applications
Analysis Note
Theoretical Plates (N/m) (1,2-Benzanthracene): ≥ 170000
Symmetry (1,2-Benzanthracene): 0.8 - 1.4
Capacity factor (1,2-Benzanthracene): 8.5 - 11.5
Legal Information
1 of 1
Ta pozycja | |||
|---|---|---|---|
| separation technique reversed phase, supercritical fluid (SFC) | separation technique reversed phase, supercritical fluid (SFC) | separation technique reversed phase, supercritical fluid (SFC) | separation technique reversed phase, supercritical fluid (SFC) |
| particle size 2 μm | particle size 2 μm | particle size 2 μm | particle size 2 μm |
| matrix active group C18 bonding phase | matrix active group C18 bonding phase | matrix active group C18 bonding phase | matrix active group C18 bonding phase |
| pore size 120 Å pore size | pore size 120 Å pore size | pore size 120 Å pore size | pore size 120 Å pore size |
| technique(s) LC/MS: suitable, UHPLC: suitable, UHPLC-MS: suitable, mass spectrometry (MS): suitable (High) | technique(s) LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable, mass spectrometry (MS): suitable (High) | technique(s) LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable, mass spectrometry (MS): suitable (High) | technique(s) LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable, mass spectrometry (MS): suitable (High) |
| matrix fully porous particle | matrix fully porous particle | matrix fully porous particle | matrix fully porous particle |
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Produkty
Find more about the analysis of 16 PFAS in salmon via QuEChERS extraction and LC-MS/MS characterization following FDA Method C-010.02.
Guidance on PFAS testing for LC and GC columns, solvent verification, isomer resolution strategies, and hardware choices for trace-level workflows.
Powiązane treści
PFAS, czyli "wieczne chemikalia", utrzymują się w środowisku i stanowią zagrożenie dla zdrowia ludzkiego. Odkryj nasze narzędzia do monitorowania środowiska w celu kwantyfikacji PFAS, pomagające badaczom, organom regulacyjnym i laboratoriom w testowaniu PFAS.
Numer pozycji handlu globalnego
| SKU | NUMER GTIN |
|---|---|
| 1506490001 | 04027269208127 |