Przejdź do zawartości
Merck
Wszystkie zdjęcia(1)

Dokumenty

1.50497

Supelco

SeQuant® ZIC®-HILIC 200Å (5 µm) HPLC Columns

L × I.D. 150 mm x 21.2 mm HPLC Column, PEEK-lined stainless steel

Zaloguj sięWyświetlanie cen organizacyjnych i kontraktowych


About This Item

Kod UNSPSC:
41115709

product name

SeQuant® ZIC-HILIC (5µm,200Å) 150 x 21.2 mm, stainless steel column, suitable for HPLC

Materiały

stainless steel column

Poziom jakości

agency

suitable for USP L114

linia produktu

SeQuant®

Właściwości

endcapped: no

Parametry

400 bar pressure
70 °C max. temp.

metody

HPLC: suitable
LC/MS: suitable (Prep LC)
mass spectrometry (MS): suitable (High)

kolumna dł. × śr. wewn.

15 cm × 21.2 mm

macierz

fully porous particle

grupa aktywna macierzy

ZIC-HILIC bonding phase

wielkość cząstki

5 μm

wielkość porów

200 Å pore size

pH robocze

2-7.5

metoda separacji

hydrophilic interaction (HILIC)

temp. przechowywania

no temp limit

Opis ogólny

SeQuant® ZIC®-HILIC Columns are designed to retain and separate all types of polar and hydrophilic compounds and for robust chromatography with high selectivity and reproducibility. The silica-based ZIC®-HILIC sorbent has a bonded stationary phase consisting of a highly polar, permanent zwitterion. Separation selectivity is favored by the 1:1 zwitterion charge balance, which makes the ZIC®-HILIC Column overall neutral, with weak, but important, ionic interactions. Tuning of the selectivity on the ZIC®-HILIC Column during method development is facilitated by the pH-inpendent permanent zwitterion, ensuring that only the analytes (and not the column) are affected during eluent optimization.The Pore size of 200 Å makes this column perfectly suitable for the separation of larger polar molecules under HILIC conditions.The column dimension of 150 mm length x 21.2 mm ID is the best choice for the semi-preparative separation of polar compounds.Thanks to their favorable retention and robust performance, SeQuant® HILIC columns have become extremely popular in numerous laboratories around the world. For example, US FDA (United States Food and Drug Administration) has recommended SeQuant® ZIC®-HILIC for analysis of melamine and related substances. SeQuant® HILIC columns excel in stability and low bleed. These features make them particularly suitable for LC-MS applications where high background can lead to signal suppression and interference with quantitative measurements while also increasing instrument wear. Their high stability makes these high-performance HILIC columns also attractive for traditional HPLC applications.Learn more about the Supelco HPLC Column portfolio and Method development:Brochure: HPLC and UHPLC Column Selection Guide Brochure: A Practical Guide to HPLC - Method Development Guide

Komentarz do analizy

Theoretical Plates (N/m) (Cytosine): ≥ 60000
Symmetry (Cytosine): 0.95 - 1.40

Informacje prawne

SeQuant is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC is a registered trademark of Merck KGaA, Darmstadt, Germany
ZIC-HILIC is a trademark of Merck KGaA, Darmstadt, Germany
This page may contain text that has been machine translated.

Certyfikaty analizy (CoA)

Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.

Masz już ten produkt?

Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.

Odwiedź Bibliotekę dokumentów

Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.

Skontaktuj się z zespołem ds. pomocy technicznej