The LiChrospher Si 100 (5um) Hibar TS 250-4 HPLC column is suitable for use in normal phase and HILIC modes, as well as SFC. For water-insoluble compounds that are organic solvent soluble, normal phase mode is the mode of choice. The mobile phase for normal phase mode includes n-hexane, n-heptane, dichloromethane, and dichloroethane, with small amounts of diethyl ether, methyl acetate, ethyl acetate, acetone, isopropanol, ethanol, or methanol as modifiers to shorten retention time. An example is 95% hexane/5% ethyl acetate. The combination of solvents used depends on the analytes of interest.
Wybierz wielkość
| Gabaryty przesyłki | SKU | Dostępność | Cena netto |
|---|---|---|---|
| 1 unit | Skontaktuj się z Obsługą Klienta, aby uzyskać informacje na temat dostępności | 3830,00 zł |
Informacje o tej pozycji
3830,00 zł
Nazwa produktu
LiChrospher® Si 100 (5 µm) Hibar® RT 250-4, suitable for HPLC
material
stainless steel column
Quality Level
agency
suitable for USP L3
product line
LiChrospher®
feature
endcapped: no
parameter
400 bar pressure, 60 °C max. temp.
technique(s)
HPLC: suitable, mass spectrometry (MS): suitable (Low - Medium)
column L × I.D.
25 cm × 4 mm
surface area
350 m2/g
matrix
fully porous particle
matrix active group
Silica bonding phase
particle size
5 μm
pore size
100 Å pore size
operating pH range
2-7.5
separation technique
hydrophilic interaction (HILIC), normal phase, supercritical fluid (SFC)
storage temp.
no temp limit
General description
Analysis Note
Theoretical Plates (N/m) (2-Nitrotoluene): ≥ 55000
Symmetry (2-Nitrotoluene): 0.8 - 1.4
Capacity factor (2-Nitrotoluene): 0.5 - 2.0
Legal Information
1 of 1
Ta pozycja | |||
|---|---|---|---|
| particle size 5 μm | particle size 5 μm | particle size 5 μm | particle size 5 μm |
| separation technique hydrophilic interaction (HILIC), supercritical fluid (SFC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase | separation technique hydrophilic interaction (HILIC), normal phase |
| matrix active group Silica bonding phase | matrix active group Silica bonding phase | matrix active group Silica bonding phase | matrix active group Silica bonding phase |
| pore size 100 Å pore size | pore size 60 Å pore size | pore size 60 Å pore size | pore size 60 Å pore size |
| agency suitable for USP L3 | agency suitable for USP L3 | agency suitable for USP L3 | agency suitable for USP L3 |
| matrix fully porous particle | matrix fully porous particle | matrix fully porous particle | matrix fully porous particle |
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Numer pozycji handlu globalnego
| SKU | NUMER GTIN |
|---|---|
| 1503160001 | 04022536232683 |
-
What type of mobile phase is used with the LiChrospher Si for the analysis of water-insoluble oils?
1 answer-