サイズを選択してください
| 容量 | カタログ番号 | 在庫状況 | 単価 |
|---|
この商品について
material
Amicon Ultra styrene-butadiene device, Ultracel® regenerated cellulose membrane (Amicon Ultra-0.5; low binding), polyethylene cap, polyethylene frit, polypropylene device (for exchange), polypropylene frit, polypropylene tube (AU0.5; for collection), polypropylene tube (for collection), polypropylene tube (holder)
sterility
non-sterile
product line
Amicon®
manufacturer/tradename
Amicon® Pro
parameter
10 mL sample volume
technique(s)
buffer exchange: suitable, protein purification: suitable (antibody labeling), protein purification: suitable (concentration), protein purification: suitable (enrichment)
L
12 cm (4.7 in.)
diam.
2.97 cm
filtration area
1 cm2
working volume
10 mL
pore size
30 kDa NMWCO
shipped in
wet ice
General description
Application
Features and Benefits
Physical form
Legal Information
1 of 1
当該品目 | |||
|---|---|---|---|
| manufacturer/tradename Amicon® Pro | manufacturer/tradename Amicon® Pro | manufacturer/tradename Amicon® Pro | manufacturer/tradename Amicon® Pro |
| parameter 10 mL sample volume | parameter 10 mL sample volume | parameter 10 mL sample volume | parameter 10 mL sample volume |
| pore size 30 kDa NMWCO | pore size 50 kDa NMWCO | pore size 10 kDa NMWCO | pore size 100 kDa NMWCO |
| sterility non-sterile | sterility non-sterile | sterility non-sterile | sterility non-sterile |
| material Amicon Ultra styrene-butadiene device, polyethylene cap, polypropylene device (for exchange), polypropylene tube (AU0.5; for collection), polypropylene tube (holder), Ultracel® regenerated cellulose membrane (Amicon Ultra-0.5; low binding), polypropylene frit, polyethylene frit, polypropylene tube (for collection) | material Amicon Ultra styrene-butadiene device, Ultracel® regenerated cellulose membrane (Amicon Ultra-0.5; low binding), polyethylene cap, polyethylene frit, polypropylene device (for exchange), polypropylene frit, polypropylene tube (AU0.5; for collection), polypropylene tube (for collection), polypropylene tube (holder) | material Amicon Ultra styrene-butadiene device, Ultracel® regenerated cellulose membrane (Amicon Ultra-0.5; low binding), polyethylene cap, polyethylene frit, polypropylene device (for exchange), polypropylene frit, polypropylene tube (AU0.5; for collection), polypropylene tube (for collection), polypropylene tube (holder) | material Amicon Ultra styrene-butadiene device, Ultracel® regenerated cellulose membrane (Amicon Ultra-0.5; low binding), polyethylene cap, polyethylene frit, polypropylene device (for exchange), polypropylene frit, polypropylene tube (AU0.5; for collection), polypropylene tube (for collection), polypropylene tube (holder) |
| working volume 10 mL | working volume 10 mL | working volume 10 mL | working volume 10 mL |
signalword
Danger
hcodes
Hazard Classifications
Flam. Liq. 2 - Met. Corr. 1
保管分類
3 - Flammable liquids
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Please refer to KIT Component information
pdsc
Please refer to KIT Component information
prtr
Please refer to KIT Component information
fsl
Please refer to KIT Component information
ishl_indicated
Please refer to KIT Component information
ishl_notified
Please refer to KIT Component information
cart
キットコンポーネントの情報を参照してください
jan
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
関連コンテンツ
bios-C-epdf-1043-1304-SP
When you start with consistent yields of active, native-folded protein, you’re giving your experiment the best chance to succeed. If your current protein preps involve juggling columns, dialyzers and multiple transfer steps, you could be introducing variability into your data. For your next protein preparation, choose the simple, gentle method that tackles even the most labile and poorly expressed proteins—the Amicon® Pro purification system. When your proteins behave, your research will flourish.