コンテンツへスキップ
Merck

スキップする

EC810

GenElute -E Viral RNA/DNA Swab Kit

Reagents and consumables for viral RNA and DNA purification. 10, 50 or 250 purifications.

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する
容量カタログ番号在庫状況単価
50 reactions

在庫あり出荷可能from市川市大町368

¥43,700
250 reactions
カートの在庫状況を確認する
¥193,000

この商品について

UNSPSC Code:
41105501
NACRES:
NB.23

¥43,700


在庫あり出荷可能詳細


テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


Quality Segment

technique(s)

DNA purification: suitable, RNA purification: suitable

input

sample(s) (swabs: nasopharyngeal and genital)
sample(s) (stool)

test parameters

: 3 min hands on time, sample volume: 10-20 mg stool, sample volume: 50 μL swabs

storage temp.

2-8°C

General description

GenElute-E purification kits provide a simple alternative for viral RNA and DNA purification. Compared with traditionalmethods, GenElute-E offers:
  • Isolation of viral RNA and DNA in less than 30 minutes with minimal sample handling
  • Better purity, leading to improved performance in PCR and other applications
  • Significant reduction in plastic and hazardous chemical waste

Traditional silica-based, bind-wash-elute purification kits require multiple wash steps to remove impurities from the spin columns. These steps increase the risk of cross contamination, and subject the nucleic acids to centrifugation sheering forces.

GenElute-E kits employ size exclusion negative chromatography to separate large nucleic acid molecules from smaller protein, lipid, and ionic components in swab, cell, tissue, blood, and other samples. Single-spin columns efficiently absorb and retain cellular debris and sample contaminantswhile allowing nucleic acids to pass through, reducing the number of steps and plastic materials required for purification. This novel method for high-qualitypurification is made possible by our innovative SmartLyse® Buffer, which enables fast and efficient isolation.

Isolate nucleic acid in a fraction of time compared to traditional silica bind-wash-elute procedures. Simply prepare spin column, mix sample with lysis components, pipette sample onto the spin column, and centrifuge directly into a collection tube. Cellular debris and contaminants remain bound in the column to be discarded, while purified viral RNA and DNA is ready to be used in downstream applications or stored.

Application

Suitable for most common downstream applications, including genotyping, PCR, and NGS
The GenElute-E Viral RNA/DNA Swab kit has been developed to purify genomic viral RNA and DNA from nasopharyngeal swabs, dry or in transport medium, in addition to genital swabs and stool samples.

The sample lysis utilizes the SmartLyse® Viral Buffer for fast and efficient isolation of nucleic acids from a variety of swab types and stool samples.

Purified viral RNA and DNA is eluted in Tris buffer, pH 7.8 and can immediately be used for most common downstream applications, including PCR, genotyping, NGS, and others. Final yield is comparable to most common silica-based methods. GenElute-E purified genomic DNA preparations commonly show an A260/280 ratio of around 1.8.

Features and Benefits

  • Fast and efficient purification: no lysis incubation and minimal hands-on, preparation steps
  • Higher quality nucleic acids: negative chromotography-based purification reduces carryover of PCR inhibitors and other contaminents
  • Reduced environmental impact: 55% less plastic waste, as well as a significant reduction in hazardous chemicals

Other Notes

We believe that green chemistry will contribute to a better tomorrow. With a growing portfolio of greener alternatives, there are now more choices to reduce the ecological impact of your research while still delivering quality and efficacy so your results are not compromised.  The single-spin protocol limits the number of collection and pipetting steps, reducing plastic waste by 55% compared to equivalent bind-wash-elute methods. GenElute-E is designated a Greener Alternative Product based on the ""Prevention"" and ""Designing Safer Chemicals"" qualifications of The 12 Principles of Green Chemistry.GenElute-E kits also adhere to the principles of SMASH Packaging, our global initiative to improve the sustainability through the reduction of packaging materials, the increased use of sustainable alternatives, and improved recyclability. Packaging is FCS-marked for sustainable forestry practices and produced from greater than 70% recycled content.

Legal Information

GenElute is a trademark of Sigma-Aldrich Co. LLC
SmartLyse is a registered trademark of Merck KGaA, Darmstadt, Germany

類似品目との比較

比較内容をすべて表示

相違点を表示

1 of 1

当該品目
EC848EC896EC996
technique(s)

DNA purification: suitable, RNA purification: suitable

technique(s)

-

technique(s)

-

technique(s)

-

input

sample(s) (swabs: nasopharyngeal and genital)
sample(s) (stool)

input

DNA
RNA

input

DNA
RNA

input

RNA
DNA

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

room temp

test parameters

: 3 min hands on time, sample volume: 50 μL swabs, sample volume: 10-20 mg stool

test parameters

-

test parameters

-

test parameters

-

Quality Level

100

Quality Level

100

Quality Level

100

Quality Level

100


キットの構成要素のみ

製品番号
詳細

  • SmartLyse® Viral Buffer

  • GenElute-E Spin Columns



最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする


資料

GenElute™-E DNA purification kits ensure accurate DNA quantitation and downstream enzymatic processes.

GenElute™-E DNA 精製キットは、DNA定量と下流酵素プロセスの精度を保証します。

関連コンテンツ

Products and support for mpox research, offering world-class reagents for immunoassay and molecular assay development.

GenElute™-E Single Spin DNA/RNA精製・ネガティブクロマトグラフィーに関するよくあるお問い合わせ・回答

GenElute™-E Single Spin DNA/RNA prepキットを使って、よりサステナブルなラボのために、プラスチックゴミを減らし、危険な液体廃棄物をなくしましょう。

すべての関連コンテンツを見る





質問

1–4/4 質問  
  1. Genelute-e single spin DNA and RNA purification kits use negative chromatographty to isolate nucleic acids. Can you explain how this approach simplifies workflows?

    1 回答
    1. Instead of optimizing the bind, wash, and release steps in conventional silica-based spin purification preps, the technology focuses on a separation by performing a single step fractionation based on the size of the biomolecules, which results in depleted impurities.

      役に立ちましたか?

  2. Do we know how stable the purified DNA is through several freeze-thaw cycles?

    1 回答
    1. This will fluctuate due to sample variability (sample collection, concentration, fragment length, sequence [GC content], storage before isolation, etc.). However, the sample is buffer exchanged into a standard storage buffer that is included in the kit (1X TE).

      役に立ちましたか?

  3. What is the composition of the lysis buffer and clearing buffer after flowing through the resin?

    1 回答
    1. The presence of EDTA, SDS, or excess salt can affect my PCR/ sequencing reaction. The lysis buffer information is proprietary, but we can say it is free of chaotropic salts. The resins are desalting resins so EDTA, SDS, and salts are depleted.

      役に立ちましたか?

  4. Does the technology introduce any bias into the sample?

    1 回答
    1. GenElute™-E does not introduce biases that some “bind-wash-elute” technologies can add because the technology separates by size, rather than by what binds and what is released.

      役に立ちましたか?

レビュー

評価値なし

アクティブなフィルタ