The control beads are utilized to demonstrate consistency across the assay plate. Each bead is conjugated with varying amounts of immunoglobulin, resulting in different levels of relative MFI. The negative control bead is not conjugated with immunoglobulin and serves as a blank. These controls are not intended for analysis but should indicate a trend, with the negative bead reading at background levels, control bead 1 exhibiting high MFI, and control beads 2 and 3 showing lower readings.
Informazioni su questo articolo
species reactivity
human
manufacturer/tradename
Milliplex®
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex® xMAP®)
storage temp.
2-8°C
General description
Application
Features and Benefits
Packaging
Preparation Note
Legal Information
Disclaimer
1 of 1
Questo articolo | |||
|---|---|---|---|
| species reactivity human | species reactivity human | species reactivity human | species reactivity - |
| manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename SMC® |
| technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) single molecule counting: suitable |
| storage temp. 2-8°C | storage temp. 2-8°C | storage temp. 2-8°C | storage temp. 2-8°C |
| detection method fluorometric (Luminex® xMAP®) | detection method fluorometric (Luminex® xMAP®) | detection method fluorometric (Luminex® xMAP®) | detection method - |
signalword
Warning
hcodes
Hazard Classifications
Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
Classe di stoccaggio
12 - Non Combustible Liquids
flash_point_f
Not applicable
flash_point_c
Not applicable
wgk
WGK 3
Certificati d'analisi (COA)
Cerca il Certificati d'analisi (COA) digitando il numero di lotto/batch corrispondente. I numeri di lotto o di batch sono stampati sull'etichetta dei prodotti dopo la parola ‘Lotto’ o ‘Batch’.
Possiedi già questo prodotto?
I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.
-
I am using the HC19SERA1-85 K SARs Ag Panel IgA kit. WHy are the controls also magnetic beads? I do not understand how this will work if I add the controls to my Plasma sample? Won't this give me false positives?
1 risposta-
Utile?
-
-
We are running the SARS-CoV-2 IgG, IgA, and IgM kits for the first time on the MagPix. What analysis settings should be used since the kit does not include a standard? Are there any units that should be entered?
1 risposta-
For Qualitative Assays, the Analysis Type is "None" in xPonent. There are no units to be entered. Median values are used for the data comparison between treatment groups.
Utile?
-