Passa al contenuto
Merck

Vai a

SEP030

Seppro IgY14

LC5

Autenticati per visualizzare i prezzi organizzativi e contrattuali.

Informazioni su questo articolo

NACRES:
NA.32
UNSPSC Code:
12352200
Clone:
-
Species reactivity:
-
Application:
Citations:
3


column D × L

12.7 mm × 39.5 mm

capacity

5 mg total protein loading(71 μL of human plasma, average human protein concentration 70 mg/mL)

storage temp.

2-8°C

General description

Seppro IgY14 columns allow users to separate 14 highly abundant proteins (HAP) from plasma protein mixtures. The Avian polyclonal IgY (Immunoglobulin Yolk) antibodies, have a distinct, highly specific partitioning advantage over competing products, allowing the researcher to look at a much cleaner human protein mixture. Seppro columns make further proteomics analysis into the plasma proteome much easier and provide cleaner results.

Proteins Depleted:

Albumin
IgG
α1-Antitrypsin
IgA
IgM
Transferrin
Haptoglobin
α2-Macroglobulin
Fibrinogen
Complement C3
α1-Acid Glycoprotein (Orosomucoid)
HDL (Apolipoproteins A-I and A-II)
LDL (mainly Apolipoprotein B)

Application

Seppro IgY14, LC5 (5 mL bed volume columns) is designed for use as a plasma/serum protein removal tool base upon immune affinity removal of 14 highly abundant proteins (HAP) from human plasma protein mixtures via liquid chromatography.[1] Seppro IgY14 is used to support the analysis of low abundance human serum/plasma proteins.[2]

Legal Information

Seppro is a trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?

Explore all of our products under Seppro® IgY14


I componenti del kit sono disponibili anche separatamente

N° Catalogo
Descrizione
SDS & Determinazione del prezzo

  • Seppro Dilution buffer
    SDS

  • Seppro Stripping Buffer
    SDS

  • Seppro Neutralization Buffer
    SDS

  • Corning® Costar® Spin-X® centrifuge tube filters, cellulose acetate membrane, pore size 0.45 μm, non-sterile
    SDS

Classe di stoccaggio

10 - Combustible liquids



Scegli una delle versioni più recenti:

Certificati d'analisi (COA)

Lot/Batch Number

Non trovi la versione di tuo interesse?

Se hai bisogno di una versione specifica, puoi cercare il certificato tramite il numero di lotto.

Possiedi già questo prodotto?

I documenti relativi ai prodotti acquistati recentemente sono disponibili nell’Archivio dei documenti.

Visita l’Archivio dei documenti


Contenuto correlato


R L Conhaim et al.
American journal of respiratory and critical care medicine, 153(2), 677-683 (1996-02-01)
Lung liquid conductance (Kf) is calculated as the quotient of lung lymph flow divided by net filtration pressure (Pnf), where Pnf is the balance of osmotic and hydrostatic pressures in the lung microcirculation. In protein depletion, lymph flow rises with
Does plasma protein depletion increase lung liquid conductance?
P Dodek
American journal of respiratory and critical care medicine, 154(4 Pt 1), 1213-1215 (1996-10-01)
Renato Millioni et al.
PloS one, 6(5), e19603-e19603 (2011-05-17)
To date, the complexity of the plasma proteome exceeds the analytical capacity of conventional approaches to isolate lower abundance proteins that may prove to be informative biomarkers. Only complex multistep separation strategies have been able to detect a substantial number



Numero articolo commerciale globale

SKUGTIN
SEP030-1KT04061837018008

Questions

1–6 of 6 Questions  
  1. How does the storage temperature relate to shipping conditions?

    1 answer
    1. The storage conditions that a Sigma-Aldrich catalog and label recommend for products are deliberately conservative. For many products, long-term storage at low temperatures will increase the time during which they are expected to remain in specification and therefore are labeled accordingly. Where short-term storage, shipping time frame, or exposure to conditions other than those recommended for long-term storage will not affect product quality, Sigma-Aldrich will ship at ambient temperature. The products sensitive to short-term exposure to conditions other than their recommended long-term storage are shipped on wet or dry ice. Ambient temperature shipping helps to control shipping costs for our customers. At any time, our customers can request wet- or dry-ice shipment, but the special handling is at customer expense if our product history indicates that the product is stable for regular shipment.

      Helpful?

  2. I originally purchased my Seppro IgY14 LC5 column from Genway.  Can I still contact Genway for technical support?

    1 answer
    1. All inquiries on the Seppro technology are now to be referred to Sigma-Aldrich. Customers should not contact Genway for technical assistance.

      Helpful?

  3. My protein sample contains SDS.  Is this compatible with SEP030, Seppro® IgY14?

    1 answer
    1. No. We do not recommend using protein samples containing SDS with Product No. SEP030. SDS is a detergent and would be expected to affect adversely the activity of the conjugated antibody in terms of depletion.

      Helpful?

  4. I originally purchased my Seppro IgY14 LC2 column from Genway. Can I still contact Genway for technical support?

    1 answer
    1. All inquiries on the Seppro technology are now to be referred to Sigma-Aldrich. Customers should not contact Genway for technical assistance.

      Helpful?

  5. How would I decide between Products SEP030, Seppro® IgY14, and PROT20, ProteoPrep® 20 Plasma Immunodepletion Kit?

    1 answer
    1. SEP030 is designed to deplete the top 14 abundant human proteins, while PROT20 is designed to deplete the top 20 abundant human proteins. Also, all of the antibodies in SEP030 are IgY antibodies, while the PROT20 antibodies and antibody ligands are primarily IgG-based.

      Helpful?

  6. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters