Direkt zum Inhalt
Merck

Fortfahren mit

5444

NovaSeptum® SURe Accurate Volume Syringe Sampling Unit

Manifold (5-valve) with Inlet C-Flex® Tubing, sterile; β-irradiated, volume 5 mL (20 mL)

Synonym(e):

AV syringe, Accurate Volume syringe, syringe

Anmelden zur Ansicht der Organisations- und Vertragspreise.

Größe auswählen

Ansicht ändern
PackungsgrößeSKUVerfügbarkeitPreis

Über diesen Artikel

UNSPSC Code:
41104105
Preise und Verfügbarkeit sind derzeit nicht verfügbar.
Technischer Dienst
Benötigen Sie Hilfe? Unser Team von erfahrenen Wissenschaftlern ist für Sie da.
Unterstützung erhalten

Quality Level

material

C-Flex tubing, polycarbonate Luer lock, polycarbonate body, polycarbonate container, silicone tubing

sterility

sterile; β-irradiated

product line

NovaSeptum® SURe

storage condition

room temperature

parameter

-80-50 °C temp. range (-112-122 °F), 0.50 bar max. pressure (7.25 psi)

volume

5 mL (20 mL)

fitting

Luer-Lok® inlet connection (3-piece), inlet connection (containing a male, female and an injection site), Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site)

application(s)

sterile sampling

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Ähnliche Artikel vergleichen

Vollständigen Vergleich anzeigen

Unterschiede anzeigen

1 of 1

Dieser Artikel
AC4645744AC874
fitting

Luer-Lok® inlet connection (3-piece), Luer-Lok® outlet connection (3-piece), inlet connection (containing a male, female and an injection site), outlet connection (containing a male, female and an injection site)

fitting

inlet connection (Silicone), Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site)

fitting

Luer-Lok® inlet connection (3-piece), inlet connection (containing a male, female and an injection site), Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site)

fitting

inlet connection (TPE), Luer-Lok® outlet connection (3-piece), outlet connection (containing a male, female and an injection site)

product line

NovaSeptum® SURe

product line

NovaSeptum® SURe

product line

NovaSeptum® SURe

product line

NovaSeptum® SURe

material

C-Flex tubing, polycarbonate body, silicone tubing, polycarbonate Luer lock, polycarbonate container

material

polycarbonate connector, polycarbonate container, polypropylene body, silicone tubing

material

C-Flex tubing, TPE tubing, polycarbonate Luer lock, polyethylene body, polyethylene container

material

PETG body, PETG container, TPE tubing, polycarbonate connector

sterility

sterile; β-irradiated

sterility

sterile; γ-irradiated

sterility

sterile; β-irradiated

sterility

sterile; γ-irradiated

volume

5 mL (20 mL)

volume

5 mL (20 mL)

volume

100 mL

volume

60 mL

parameter

-80-50 °C temp. range (-112-122 °F), 0.50 bar max. pressure (7.25 psi)

parameter

0.50 bar max. pressure (7.25 psi), 4-40 °C temp. range (39-104 °F)

parameter

-80-50 °C temp. range (-112-122 °F) (when used with a NovaSeptum® Case), 0.30 bar max. pressure (4.35 psi)

parameter

0.30 bar max. pressure (4.35 psi), 4-40 °C temp. range (39-104 °F)

General description

The NovaSeptum® SURe sterile sampling assembly is for single-use manufacturing processes, where aseptic connection and disconnection is necessary.
This product comes as a manifolded unit with accurate volume syringes and connects via C-flex® tubing for thermowelding. The syringes enable sampling for small, accurate volumes, which is particularly important for sampling of high value products. The closed design ensures your sample will be isolated from point of sample to analysis, reducing the risk of losing valuable product and maintaining the integrity of your fluid samples.

Application

Sterility testing, bioburden, pyrogenic testing, endotoxin testing, chemical analysis, pH analysis, fermentation applications or any other routine lab testing
Supported Liquid Extraction

Features and Benefits

  • Product design ensures process integrity and a representative sample from single-use manufacturing processes
  • Industry-standard aseptic connection and disconnection for easy integration into your single-use process
  • Other container options available: bags, bottles, syringes, and conical tubes
  • Stocked and ready-to-ship for fast delivery

Packaging

5 units per box (5*5mL) and 4 units per box (5*20mL)

Preparation Note

Assembled under ISO Clean Room Class 8 conditions in a facility certified to ISO 14644-1 standards.

Analysis Note

All component materials, in contact with sampling liquid, meet the criteria for Class VI testing based on USP 88 Biological Reactivity, in vivo.

Other Notes

Not autoclavable

Legal Information

C-Flex is a registered trademark of Saint-Gobain Performance Plastics Corp.
Luer-Lok is a registered trademark of Becton-Dickinson & Co.
NOVASEPTUM is a registered trademark of Merck KGaA, Darmstadt, Germany

Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Artikel

Ensure sample integrity and accurate results with NovaSeptum® sterile sampling containers: bags, bottles, syringes & more.

Global Trade Item Number

SKUGTIN
247073-25G04061825883854
247073-5G04061825883861
GE17-5444-1004061837622434