Direkt zum Inhalt
Merck

B6420

BES

BioXtra, ≥99.0% (titration)

Synonym(e):

N,N-Bis-(2-hydroxyethyl)-2-amino-ethansulfonsäure, N,N-Bis-(2-hydroxyethyl)-taurin

Anmelden zur Ansicht der Organisations- und Vertragspreise.

Über diesen Artikel

Empirische Formel (Hill-System):
C6H15NO5S
CAS-Nummer:
Molekulargewicht:
213.25
UNSPSC Code:
12161700
NACRES:
NA.25
PubChem Substance ID:
EC Number:
233-465-5
Beilstein/REAXYS Number:
1781572
MDL number:

Fortfahren mit

Technischer Dienst
Benötigen Sie Hilfe? Unser Team von erfahrenen Wissenschaftlern ist für Sie da.
Unterstützung erhalten

InChI key

AJTVSSFTXWNIRG-UHFFFAOYSA-N

InChI

1S/C6H15NO5S/c8-4-1-7(2-5-9)3-6-13(10,11)12/h8-9H,1-6H2,(H,10,11,12)

SMILES string

OCCN(CCO)CCS(O)(=O)=O

product line

BioXtra

assay

≥99.0% (titration)

form

crystalline

impurities

≤0.0005% Phosphorus (P), ≤0.1% Insoluble matter

ign. residue

≤0.2%

pH

2.5-5.0 (25 °C, 213.3 g/L)

useful pH range

6.4-7.8

pKa (25 °C)

7.1

solubility

H2O: 1 M, clear, colorless

anion traces

chloride (Cl-): ≤0.05%, sulfate (SO42-): ≤0.05%

cation traces

Al: ≤0.0005%, Ca: ≤0.0005%, Cu: ≤0.0005%, Fe: ≤0.0005%, K: ≤0.005%, Mg: ≤0.0005%, NH4+: ≤0.05%, Na: ≤0.005%, Pb: ≤0.001%, Zn: ≤0.0005%

absorption

≤0.080 at 280 in H2O at 1 M, ≤0.095 at 260 in H2O at 1 M

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Lagerklasse

11 - Combustible Solids

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

dust mask type N95 (US), Eyeshields, Gloves


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kensuke Nishimiya et al.
Circulation journal : official journal of the Japanese Circulation Society, 79(6), 1323-1331 (2015-04-07)
Coronary adventitia harbors a wide variety of components, such as inflammatory cells and vasa vasorum (VV). Adventitial VV initiates the development of coronary artery diseases as an outside-in supply route of inflammation. We have recently demonstrated that drug-eluting stent implantation
Russell A Jensen et al.
The journal of physical chemistry letters, 6(15), 2933-2937 (2015-08-13)
Colloidal CdSe quantum dot (QD) core ensembles were photodimmed and allowed to recover in the dark using ambient thermal energy at a range of temperatures. Nonlinear thermal recovery is well described by a stretched exponential function, and further analysis yields
John A Ormiston et al.
EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology, 10(12), 1449-1455 (2014-11-26)
Stent fracture is important because it may cause adverse events. The interventional cardiologist needs independent data to aid stent selection. Stent designers need data to improve stent design. We used a repetitive bend test to compare durability and fracture for
Yingjie Zhang et al.
ACS nano, 9(10), 10445-10452 (2015-09-25)
Artificial solids composed of semiconductor quantum dots (QDs) are being developed for large-area electronic and optoelectronic applications, but these materials often have defect-induced in-gap states (IGS) of unknown chemical origin. Here we performed scanning probe based spectroscopic analysis and density
Christos V Bourantas et al.
International journal of cardiology, 186, 178-185 (2015-04-02)
Numerous studies have demonstrated an association between endothelial shear stress (ESS) and neointimal formation after stent implantation. However, the role of ESS on the composition of neointima and underlying plaque remains unclear. Patients recruited in the Comfortable AMI-IBIS 4 study

Questions

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung