Über diesen Artikel

Lineare Formel:
C6H5CH3
CAS-Nummer:
Molekulargewicht:
92.14
EC Index Number:
203-625-9
UNSPSC Code:
12352005
Beilstein/REAXYS Number:
635760
MDL number:
eCl@ss:
39011102
Assay:
≥99.9% (toluene)
Technique(s):
HPLC: suitable, LC/MS: suitable, gas chromatography (GC): suitable
Bp:
110-111 °C (lit.)
Vapor pressure:
22 mmHg ( 20 °C), 26 mmHg ( 25 °C)
Preise und Verfügbarkeit sind derzeit nicht verfügbar.
Technischer Dienst
Benötigen Sie Hilfe? Unser Team von erfahrenen Wissenschaftlern ist für Sie da.
Unterstützung erhalten


Quality Level

agency

suitable for EPA 1613, suitable for EPA 1633

vapor density

3.2 (vs air)

vapor pressure

22 mmHg ( 20 °C), 26 mmHg ( 25 °C)

product line

OmniSolv®

assay

≥99.9% (toluene)

form

liquid

autoignition temp.

997 °F

expl. lim.

7 %

technique(s)

HPLC: suitable, LC/MS: suitable, gas chromatography (GC): suitable

impurities

≤0.02% Water (H2O), ≤5 ng/L Capillary ECD responsive substances (as PCNB)

evapn. residue

≤3 ppm

color

APHA: ≤10

refractive index

n/D 1.496 (lit.)

bp

110-111 °C (lit.)

mp

-93 °C (lit.)

transition temp

flash point 4 °C

solubility

0.52 g/L

density

0.865 g/mL at 25 °C (lit.)

UV cutoff

≤285 nm

UV absorption

λ: 285 nm Amax: ≤1.00, λ: 286 nm Amax: ≤0.70, λ: 288 nm Amax: ≤0.40, λ: 300 nm Amax: ≤0.10, λ: 350 nm Amax: ≤0.01

application(s)

PFAS testing

shipped in

ambient

storage temp.

room temp

SMILES string

Cc1ccccc1

InChI

1S/C7H8/c1-7-5-3-2-4-6-7/h2-6H,1H3

InChI key

YXFVVABEGXRONW-UHFFFAOYSA-N

General description

Toluene is a high-purity, non-polar organic solvent widely used in gas chromatography (GC), high-performance liquid chromatography (HPLC), and sample preparation workflows. Due to its low UV absorbance and excellent solvating power for hydrophobic compounds, toluene is ideal for separating aromatic hydrocarbons, lipids, and other non-polar analytes. It ensures minimal interference from impurities, making it suitable for trace-level detection and quantification in environmental, pharmaceutical, and petrochemical analyses.

Application

  • a Toluene is commonly used as a solvent and carrier medium in GC for the analysis of volatile organic compounds (VOCs), especially aromatic hydrocarbons
  • In normal-phase HPLC, toluene serves as a non-polar mobile phase component for separating hydrophobic analytes such as polycyclic aromatic hydrocarbons (PAHs) 
  • Used as a mobile phase to separate C₆₀ and C₇₀ fullerenes by gel permeation chromatography
OmniSolv®
TX0737P-1 is packaged in poly coated glass bottles

Packaging

M-Bottle for Solvents
As a global leader in lab reagents, we are constantly looking for new ways to optimize the safety of our products. The newly developed 4L solvent bottle design features advanced sealing technology that eliminates leaks to make the handling of solvents safer and more convenient than ever before.
See all the new features here!
is packaged in 1L amber glass bottle
is packaged in 4L amber glass bottle
is packaged in 4L polycoated glass bottle

Preparation Note

Product filtered through a 0.2 μm filter

Analysis Note

Assay (Toluene)99.9% minCapillary ECD responsive substances (as PCNB)5ng/L maxColor (APHA)10 maxEvaporation residue3ppm maxFiltered through 0.2 µm filterTo pass testFormClear liquidInfrared SpectrumConforms to standardRefractive index (at 20°C)UV Abs. at 285 nm1.00AU maxUV Abs. at 286 nm0.70AU maxUV Abs. at 288 nm0.40AU maxUV Abs. at 300 nm0.10AU maxUV Abs. at 350 nm0.01AU maxUV Cut-off285nm maxWater (H2O)0.02% max

Legal Information

OMNISOLV is a registered trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?

Explore all of our products under Toluol


signalword

Danger

Hazard Classifications

Aquatic Chronic 3 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

target_organs

Central nervous system

Lagerklasse

3 - Flammable liquids

wgk

WGK 3

flash_point_f

39.9 °F - closed cup

flash_point_c

4.4 °C - closed cup


Zulassungslistungen

Zulassungslistungen werden hauptsächlich für chemische Produkte erstellt. Für nicht-chemische Produkte können hier nur begrenzte Angaben gemacht werden. Kein Eintrag bedeutet, dass keine der Komponenten gelistet ist. Es liegt in der Verantwortung des Benutzers, die sichere und legale Verwendung des Produkts zu gewährleisten.

108-88-3

CAS No.


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen


Verwandter Inhalt

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.





Global Trade Item Number

SKUGTIN
TX0737-604061839446496
TX0737-104061839446465
TX0737-NP2004061839446502
TX0737-3104061839446472
TX0737P-104061839446540

Questions

Reviews

No rating value

Active Filters