Größe auswählen
| Ihnen/SKU | Verfügbarkeit | Preis |
|---|
Über diesen Artikel
biological source
human
Quality Segment
recombinant
expressed in Chem-1 cells
manufacturer/tradename
ChemiScreen, Chemicon®
technique(s)
ligand binding assay: suitable (GTPγS), radioligand binding assay (RLBA): suitable
NCBI accession no.
UniProt accession no.
shipped in
dry ice
storage temp.
-65 to -96°C
Gene Information
human ... CHRM5(1133)
General description
Application
Biochem/physiol Actions
Features and Benefits
Membranes are mixed with radioactive ligand and unlabeled competitor (see Figures 1 and 2 for concentrations tested) in binding buffer in a nonbinding 96-well plate, and incubated for 1-2 h. Prior to filtration, a GF/C 96-well filter plate is coated with 0.33% polyethyleneimine for 30 min, then washed with 50mM HEPES, pH 7.4, 0.5% BSA. Binding reaction is transferred to the filter plate, and washed 3 times (1 mL per well per wash) with Wash Buffer. The plate is dried and counted. Binding buffer: 50 mM Hepes, pH 7.4, 5 mM MgCl2, 1 mM CaCl2, 0.2% BSA, filtered and stored at 4°C Radioligand: [3H] NMS (Perkin Elmer#:NEX-636 )
Wash Buffer: 50 mM Hepes, pH 7.4, 500 mM NaCl , 0.1% BSA, filtered and stored at 4°C.
One package contains enough membranes for at least 200 assays (units), where a unit is the amount of membrane that will yield greater than 5-fold signal:background with 3H-labeled NMS at 1 nM
Physical form
Preparation Note
Analysis Note
1 unit = 10 μg
Legal Information
Disclaimer
1 of 1
Dieser Artikel | |||
|---|---|---|---|
| NCBI accession no. | NCBI accession no. NM_000739.2, NM_001006626.1, NM_001006627.1, NM_001006628.1, NM_001006629.1, NM_001006630.1, NM_001006631.1, NM_001006632.1 | NCBI accession no. | NCBI accession no. |
| shipped in dry ice | shipped in dry ice | shipped in dry ice | shipped in dry ice |
| recombinant expressed in Chem-1 cells | recombinant expressed in Chem-1 cells | recombinant expressed in Chem-1 cells | recombinant expressed in Chem-5 cells |
| technique(s) ligand binding assay: suitable (GTPγS), radioligand binding assay (RLBA): suitable | technique(s) radioligand binding assay (RLBA): suitable | technique(s) ligand binding assay: suitable (GTPγS), radioligand binding assay (RLBA): suitable | technique(s) ligand binding assay: suitable (GTPγS), radioligand binding assay (RLBA): suitable |
| biological source human | biological source human | biological source human | biological source human |
| storage temp. -65 to -96°C | storage temp. -65 to -96°C | storage temp. -65 to -96°C | storage temp. -65 to -96°C |
Lagerklasse
10 - Combustible liquids
wgk
WGK 2
Analysenzertifikate (COA)
Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.