The control beads are utilized to demonstrate consistency across the assay plate. Each bead is conjugated with varying amounts of immunoglobulin, resulting in different levels of relative MFI. The negative control bead is not conjugated with immunoglobulin and serves as a blank. These controls are not intended for analysis but should indicate a trend, with the negative bead reading at background levels, control bead 1 exhibiting high MFI, and control beads 2 and 3 showing lower readings.
A propos de cet article
species reactivity
human
manufacturer/tradename
Milliplex®
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex® xMAP®)
storage temp.
2-8°C
General description
Application
Features and Benefits
Packaging
Preparation Note
Legal Information
Disclaimer
1 of 1
Cet article | |||
|---|---|---|---|
| species reactivity human | species reactivity human | species reactivity human | species reactivity SARS virus |
| manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename - |
| technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) multiplexing: suitable | technique(s) ELISA: suitable |
| storage temp. 2-8°C | storage temp. 2-8°C | storage temp. 2-8°C | storage temp. −20°C |
| detection method fluorometric (Luminex® xMAP®) | detection method fluorometric (Luminex® xMAP®) | detection method fluorometric (Luminex® xMAP®) | detection method - |
signalword
Warning
hcodes
Hazard Classifications
Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1
Classe de stockage
12 - Non Combustible Liquids
flash_point_f
Not applicable
flash_point_c
Not applicable
wgk
WGK 3
Certificats d'analyse (COA)
Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Contenu apparenté
Uncover tips and tricks to multiplexing in this guide from the experts. Learn how you can enhance the power of your research with MILLIPLEX® multiplexing, including industry guidance for immunoassays, multiplexing tips, one-day MILLIPLEX® multiplex assays for limited lab time, and more.
-
I am using the HC19SERA1-85 K SARs Ag Panel IgA kit. WHy are the controls also magnetic beads? I do not understand how this will work if I add the controls to my Plasma sample? Won't this give me false positives?
1 answer-
Helpful?
-
-
We are running the SARS-CoV-2 IgG, IgA, and IgM kits for the first time on the MagPix. What analysis settings should be used since the kit does not include a standard? Are there any units that should be entered?
1 answer-
For Qualitative Assays, the Analysis Type is "None" in xPonent. There are no units to be entered. Median values are used for the data comparison between treatment groups.
Helpful?
-