Saltar al contenido
Merck

Saltar a

EC74

NovaSeptum® GO Conical Tube Sampling Unit, Manifold (5-valve)

sterile; γ-irradiated

Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
Tamaño de envaseSKUDisponibilidadPrecio

Acerca de este artículo

UNSPSC Code:
41104105
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


Quality Level

material

316L stainless steel cannula, polyester body, polyethylene bag (drainage bag (PureFlex Film)), polypropylene tube (Fluid contact layer), polystyrene device, silicone septum (Platinum-cured), silicone tube (Fluid contact layer: platinum-cured silicone), silicone tube (medical silicone fluid), silicone tubing

agency

according to ISO (sterilization), meets ISO 14644-1, meets USP 88 Biological Reactivity (all component materials)

sterility

sterile; γ-irradiated

product line

NovaSeptum® GO

feature

autoclavable: no

parameter

0.50 bar max. pressure (7.25 psi), 2-60 °C temp. range (36-140 °F)

fitting

female Luer-Lok® outlet fitting, male Luer-Lok® outlet fitting

application(s)

cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pharma/biopharma processes
sterile sampling
viral therapy

storage temp.

room temp

General description

The NovaSeptum® GO conical tube sampling unit is intended for applications where high purity, such as low endotoxin levels, is required. The conical tube has a fluid contact layer made of polystyrene making it ideal for endotoxin testing. This sampling unit is available with a 2 mm needle and must be used with a NovaSeptum® GO holder.

This is a multi-sampling (manifold) device

Application

  • Multi Sampling (Manifold)
  • Sterile Sampling

Features and Benefits

  • Fluid contact layer made of polystyrene, ideal for endotoxin testing
  • Small size, no need to aliquot
  • Manifold format

Packaging

EC74-80015: 8 units per box

Other Notes

  • Septum: Platinum-cured silicone
  • Body: Polyester
  • Cannula: ASTM® 316 L Stainless steel
  • Drainage bag: Polyethylene film (PureFlex film)
  • Fluid contact layer (tube): Polypropylene, platinum-cured silicone, medical silicone fluid
  • Tubing: Silicone
  • Outlet Tubing: Female and male Luer-Lok®

Assembled under ISO Clean Room Class 8 conditions in a facility certified to ISO 14644-1 standards.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
Luer-Lok is a registered trademark of Becton-Dickinson & Co.
NOVASEPTUM is a registered trademark of Merck KGaA, Darmstadt, Germany

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
EC715C445D41
fitting

female Luer-Lok® outlet fitting, male Luer-Lok® outlet fitting

fitting

female Luer-Lok® outlet fitting, male Luer-Lok® outlet fitting

fitting

-

fitting

-

product line

NovaSeptum® GO

product line

NovaSeptum® GO

product line

NovaSeptum® GO

product line

NovaSeptum® GO

material

316L stainless steel cannula, polyethylene bag (drainage bag (PureFlex Film)), polystyrene device, silicone tube (Fluid contact layer: platinum-cured silicone), silicone tubing, polyester body, silicone septum (Platinum-cured), polypropylene tube (Fluid contact layer), silicone tube (medical silicone fluid)

material

316L stainless steel cannula, polyester body, polypropylene tube (Fluid contact layer), polystyrene device, silicone septum (Platinum-cured), silicone tube (Fluid contact layer: platinum-cured silicone), silicone tube (medical silicone fluid), silicone tubing

material

TPE tubing (Inlet C-Flex), polycarbonate Luer lock, polypropylene clip (TTP clip), polypropylene tube (Fluid contact layer (conical tube)), polystyrene tube (Fluid contact layer (conical tube)), tubing (Female and male Luer-Lok®)

material

TPE tubing (Inlet C-Flex), polycarbonate Luer lock, polypropylene clip (TTP clip), polypropylene tube (Fluid contact layer (conical tube)), polystyrene tube (Fluid contact layer (conical tube)), tubing (Female and male Luer-Lok®)

feature

autoclavable: no

feature

autoclavable: no

feature

autoclavable: no

feature

autoclavable: no

Quality Level

400

Quality Level

400

Quality Level

400

Quality Level

400

application(s)

cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pharma/biopharma processes
sterile sampling
viral therapy

application(s)

cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pharma/biopharma processes
sterile sampling
viral therapy

application(s)

cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pharma/biopharma processes
sterile sampling
viral therapy

application(s)

cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pharma/biopharma processes
sterile sampling
viral therapy




Cumpla las GMP con el programa Emprove®.

Acelere la cualificación, mantenga la conformidad y ahorre tiempo con Emprove® Dossiers.

Descargar Dossiers

Nota: será redirigido a EmproveSuite.com. Su nombre de usuario y contraseña son independientes de SigmaAldrich.com y pueden diferir.

Regístrese gratis y acceda a Emprove® Dossiers en cuestión de minutos. Actualice su plan de suscripción para desbloquear contenidos avanzados y personalizados en la Emprove® Suite

¿No encuentra lo que busca? Visite la página de ayuda del programa Emprove®..

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos


Artículos

Struggling to find a sampling solution for your process? Explore sterile manual and automated aseptic sampling to ensure product quality and safety.

Explore the importance of closed sampling in pharma manufacturing, focusing on regulatory guidance, bioburden control, and process monitoring.

Symbolic depiction of a (bio-)pharmaceutical process with persons in lab coats working, possibly taking samples.

Ver todos los artículos

Contenido relacionado

NovaSeptum® GO sterile sampling unit with 15 mL single-use conical tube for small volume and endotoxin sampling. Closed design for aseptic process. Reduce product loss and risks of contamination. Available in single and manifold sampling format. Easily integrated into stainless-steel system via multi-use connection types (TC, in-line, ingold®).





Preguntas

Revisiones

Sin puntuación