Ugrás a tartalomra
Merck
  • Evaluation of injection methods for fast, high peak capacity separations with low thermal mass gas chromatography.

Evaluation of injection methods for fast, high peak capacity separations with low thermal mass gas chromatography.

Journal of chromatography. A (2015-03-31)
Brian D Fitz, Brandyn C Mannion, Khang To, Trinh Hoac, Robert E Synovec
KIVONAT

Low thermal mass gas chromatography (LTM-GC) was evaluated for rapid, high peak capacity separations with three injection methods: liquid, headspace solid phase micro-extraction (HS-SPME), and direct vapor. An Agilent LTM equipped with a short microbore capillary column was operated at a column heating rate of 250 °C/min to produce a 60s separation. Two sets of experiments were conducted in parallel to characterize the instrumental platform. First, the three injection methods were performed in conjunction with in-house built high-speed cryo-focusing injection (HSCFI) to cryogenically trap and re-inject the analytes onto the LTM-GC column in a narrower band. Next, the three injection methods were performed natively with LTM-GC. Using HSCFI, the peak capacity of a separation of 50 nl of a 73 component liquid test mixture was 270, which was 23% higher than without HSCFI. Similar peak capacity gains were obtained when using the HSCFI with HS-SPME (25%), and even greater with vapor injection (56%). For the 100 μl vapor sample injected without HSCFI, the preconcentration factor, defined as the ratio of the maximum concentration of the detected analyte peak relative to the analyte concentration injected with the syringe, was determined to be 11 for the earliest eluting peak (most volatile analyte). In contrast, the preconcentration factor for the earliest eluting peak using HSCFI was 103. Therefore, LTM-GC is demonstrated to natively provide in situ analyte trapping, although not to as great an extent as with HSCFI. We also report the use of LTM-GC applied with time-of-flight mass spectrometry (TOFMS) detection for rapid, high peak capacity separations from SPME sampled banana peel headspace.

ANYAGOK
Cikkszám
Márka
Termékleírás

Sigma-Aldrich
Cyclooctane, ≥99%
Sigma-Aldrich
Methyl hexanoate, natural, ≥99%, FG
Sigma-Aldrich
Naphthalene, 99%
Sigma-Aldrich
Undecane, ≥99%
Sigma-Aldrich
Methylcyclohexane, anhydrous, ≥99%
Sigma-Aldrich
1-Hexadecanol, ReagentPlus®, 99%
Sigma-Aldrich
2-Pentanone, ≥98%, FCC, FG
Sigma-Aldrich
Octane, anhydrous, ≥99%
Sigma-Aldrich
Tridecane, ≥99%
Sigma-Aldrich
2-Butanol, anhydrous, 99.5%
Sigma-Aldrich
Propylbenzene, 98%
Sigma-Aldrich
Rhein, technical grade
Sigma-Aldrich
1-Tetradecanol, 97%
Sigma-Aldrich
Nonane, anhydrous, ≥99%
Sigma-Aldrich
Methyl hexanoate, 99%
Supelco
2-Butanol, analytical standard
Supelco
Methyl hexanoate, analytical standard
Supelco
2-Decanone, analytical standard
Supelco
1-Propanol, analytical standard
Sigma-Aldrich
Decane, ≥95%
Supelco
Heptane, analytical standard
Supelco
Chloroform, analytical standard
Supelco
Propylbenzene, analytical standard
Supelco
Nonane, analytical standard
Sigma-Aldrich
Propylbenzene, ≥99.0% (GC)
Supelco
1-Octanol, analytical standard
Supelco
Decane, analytical standard
Supelco
3-Octanone, analytical standard
Supelco
Acetone, analytical standard
Sigma-Aldrich
3-Octanone, ≥98%