1.05544
Potassium hydroxide solution
c(KOH)=0.1 mol/l (0,1 N) in 2-propanol, DIN ISO 6618, ready-to-use for titration in non-aqueous media, Titriplex®
Szinonimák:
Potassium hydroxide solution in 2-propanol
About This Item
Javasolt termékek
Terméknév
Potassium hydroxide solution in isopropanol, acc. to DIN ISO 6618 part 1 c(KOH)=0.1 mol/l (0,1 N), Titripur®
Minőségi szint
termékcsalád
Titripur®
Forma
liquid
öngyulladási hőmérséklet
425 °C (2-Propanol)
minőség
Analyzed in our ISO 17025 accredited QC lab
robbanási határérték
2-13.4 % (v/v) 2-Propanol)
reakcióalkalmasság
reaction type: Acid-base reactions
koncentráció
0.1 M
technika/technikák
titration: suitable
pH
13 (20 °C in H2O)
átmeneti hőmérséklet
flash point 12 °C (2-Propanol)
sűrűség
0.79 g/cm3 at 20 °C
tárolási hőmérséklet
15-25°C
Tulajdonságok és előnyök
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
Kiszerelés
Analízis megjegyzés
Amount-of-substance concentration 0.0995 - 0.1005 mol/L
Measurement uncertainty ± 0.0003 mol/L
Traceability NIST SRM
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 84 potassium hydrogen phthalate) by means of volumetric standard potassium hydrogen phthalate (article number 1.02400), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
*) The concentration of this volumetric solution decreases over time of storage. This is not a quality issue of this product, it is a property of this solution. Therefore we strongly recommend to perform a titer determination after opening the originally sealed bottle and every working day.
Jogi információk
kapcsolódó termék
Figyelmeztetés
Danger
Figyelmeztető mondatok
Óvintézkedésre vonatkozó mondatok
Veszélyességi osztályok
Eye Irrit. 2 - Flam. Liq. 2 - Met. Corr. 1 - Skin Irrit. 2 - STOT SE 3
Célzott szervek
Central nervous system
Tárolási osztály kódja
3 - Flammable liquids
WGK
WGK 1
Lobbanási pont (F)
53.6 °F - (2-Propanol)
Lobbanási pont (C)
12 °C - (2-Propanol)
Analitikai tanúsítványok (COA)
Analitikai tanúsítványok (COA) keresése a termék sarzs-/tételszámának megadásával. A sarzs- és tételszámok a termék címkéjén találhatók, a „Lot” vagy „Batch” szavak után.
Már rendelkezik ezzel a termékkel?
Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.
Az ügyfelek ezeket is megtekintették
Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.
Lépjen kapcsolatba a szaktanácsadással