1.09163
Wijs solution
c(ICl) = 0.1 mol/l, for determination of iodine number, ready-to-use volumetric solution for titration in non aqueous media, Titriplex®
Szinonimák:
Iodine solution acc. to Wijs
About This Item
Javasolt termékek
product name
Wijs solution, for determination of the iodine number c(ICl) = 0.1 mol/l, Titripur®
Minőségi szint
termékcsalád
Titripur®
form
liquid
minőség
Analyzed in our ISO 17025 accredited QC lab
reakcióalkalmasság
reaction type: Redox Reactions
koncentráció
0.1 M
technika/technikák
titration: suitable
pH
<1 (20 °C in H2O)
átmeneti hőmérséklet
flash point 40 °C
sűrűség
1.06 g/cm3 at 20 °C
tárolási hőmérséklet
15-25°C
Tulajdonságok és előnyök
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
Kiszerelés
Analízis megjegyzés
Amount-of-substance concentration 0.0994 - 1.006 mol/L
Measurement uncertainty ± 0.0004 mol/L
Traceability NIST SRM
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is determined with standardized sodium thiosulfate solution (article number 1.09147). The sodium thiosulfate solution is standardized and traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 136 potassium dichromate) by means of volumetric standard potassium iodate (article number 1.02404), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
Jogi információk
kapcsolódó termék
Figyelmeztetés
Danger
Figyelmeztető mondatok
Óvintézkedésre vonatkozó mondatok
Veszélyességi osztályok
Eye Dam. 1 - Flam. Liq. 3 - Skin Corr. 1A
Tárolási osztály kódja
3 - Flammable liquids
WGK
WGK 2
Lobbanási pont (F)
104.0 °F
Lobbanási pont (C)
40 °C
Analitikai tanúsítványok (COA)
Analitikai tanúsítványok (COA) keresése a termék sarzs-/tételszámának megadásával. A sarzs- és tételszámok a termék címkéjén találhatók, a „Lot” vagy „Batch” szavak után.