Skip to Content
Merck

Skip To

8.00421

4-Aminophenol

for synthesis

Synonym(s):

4-Aminophenol, 4-Hydroxyaniline

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice

About This Item

Linear Formula:
4-(NH2)C6H4OH
CAS Number:
Molecular Weight:
109.13
UNSPSC Code:
12352104
EC Index Number:
204-616-2
NACRES:
NA.22
MDL number:
Form:
solid
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

vapor pressure

0.4 hPa ( 110 °C)

Quality Level

form

solid

autoignition temp.

>250 °C

potency

375 mg/kg LD50, oral (Rat), >10000 mg/kg LD50, skin (Rabbit)

bp

284 °C/1013 hPa (decomposition)

mp

190 °C

transition temp

flash point 195 °C

solubility

16 g/L

storage temp.

2-30°C

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
358371021204A71328
solubility

16 g/L

solubility

water: slightly soluble

solubility

-

solubility

water: slightly soluble

Quality Level

200

Quality Level

100

Quality Level

-

Quality Level

200

mp

190 °C

mp

185-189 °C (lit.)

mp

185-189 °C (lit.)

mp

185-189 °C (lit.)

storage temp.

2-30°C

storage temp.

-

storage temp.

-

storage temp.

-

form

solid

form

-

form

-

form

granular, powder or crystals

bp

284 °C/1013 hPa (decomposition)

bp

-

bp

-

bp

-

Application

<ul>
<li><strong><strong>Advances in photothermal and plasmonic catalysis:</strong></strong> 4-Aminophenol is commonly used as a vital chemical precursor in the manufacturing of preservatives, drugs, desiccants and photographic developers (Li et al., 2024).</li>
</ul>

Analysis Note

Assay (HClO₄): ≥ 99.0 %
Identity (IR): passes test

signalword

Warning

Hazard Classifications

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Acute 1 - Aquatic Chronic 1 - Muta. 2 - Skin Sens. 1 - STOT RE 2

target_organs

Kidney

wgk

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable

Storage Class

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Global Trade Item Number

SKUGTIN
800421910004022536750729
800421999904022536358871
800421025004022536358840
800421000004022536358826
800421905004022536358864
800421000504022536358833
800421100004022536358857

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service