Saltar al contenido
Merck

Saltar a

FLAA

Adenosine 5′-triphosphate (ATP) Bioluminescent Assay Kit

for ATP quantitation

Sinónimos:

ATP Bioluminescence Assay, ATP Determination Kit, Luminescent ATP Detection kit

Iniciar sesión para ver los precios por organización y contrato.

Seleccione un Tamaño

Cambiar Vistas
Tamaño de envaseSKUDisponibilidadPrecio

Acerca de este artículo

EC Number:
213-579-1
NACRES:
NA.26
eCl@ss:
32160414
UNSPSC Code:
41116133
En este momento no podemos mostrarle ni los precios ni la disponibilidad
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle


Quality Level

storage temp.

−20°C

General description

The Adenosine 5′-triphosphate (ATP) Bioluminescent Assay Kit may be employed for the quantitative bioluminescent determination of ATP in samples. ATP is consumed and light is emitted when luciferase catalyzes the oxidation of D-luciferin. When ATP is the limiting reagent, the light emitted is proportional to the ATP present in the sample.

Application

Adenosine 5′-triphosphate (ATP) Bioluminescent Assay Kit has also been used in the quantification of ATP in 3D matrixes of human neurons,[1] hepatic cells with ischemia,[2] various bacterial cultures[3] and lysosomes.[4]

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 1

Este artículo
FLASCA8937A2767
Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C


Los componentes del kit también están disponibles por separado

Referencia del producto
Descripción
SDS & Precios

  • Adenosine 5′-triphosphate (ATP) assay mix dilution buffer, lyophilized powder mL/vial
    SDS

  • Adenosine 5′-triphosphate (ATP) assay mix, lyophilized powder mL/vial
    SDS

  • Adenosine 5′-triphosphate (ATP) disodium salt hydrate, vial of ~1 mg ATP mL/vial
    SDS

pictograms

Corrosion

signalword

Danger

hcodes

Hazard Classifications

Eye Dam. 1

wgk

WGK 3

Clase de almacenamiento

11 - Combustible Solids



Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos


Contenido relacionado


Evaluation of antimicrobial activities of commercial herb and spice extracts against selected food-borne bacteria
Witkowska A M, et al.
Journal of Food Research, 2(4), 37-37 (2013)
Marco A Tavares et al.
Environmental toxicology and pharmacology, 40(1), 206-214 (2015-07-06)
Fipronil is an insecticide extensively used to control pests in crops and animals. There are relates of poisoning due to exposure of fipronil in mammals and the liver has been suggested as potential target. In this study, we evaluated the
John F C Steele et al.
PloS one, 14(8), e0221226-e0221226 (2019-08-29)
Plant NLRs are modular immune receptors that trigger rapid cell death in response to attempted infection by pathogens. A highly conserved nucleotide-binding domain shared with APAF-1, various R-proteins and CED-4 (NB-ARC domain) is proposed to act as a molecular switch



Número de artículo de comercio global

SKUGTIN
FLAA-1KT04061835556915

Questions

1–8 of 8 Questions  
  1. How many times can one do with Product FLAAS, ATP Bioluminescent Assay Kit (one vial of FLAAS) when standard range between 20uM~0.002uM?

    1 answer
    1. The number of times that one can use FLAAS ATP Assay Kit is dependent upon the sample. Frequently, serial dilutions of the sample, as well as the kit reagents, are required. If no dilutions were required the ATP Assay MIx is reconstituted to 5 mL and added to the sample at 0.1 mL. The dilution factor will need to be determined by the end-user. Please note, FLAAS is stable for at least 24 hours at 2–8 °C, or over two weeks if stored frozen at –20 °C. Working concentrations of the serially diluted standard are stable for up to 8 hours when stored in ice.

      Please view the product data sheet for more information, including dilution factor details:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/308/573/flaabul.pdf

      Helpful?

  2. How does the kit perform on samples with pH 7.3-7.4 (physiological range)? It recommends adjustment of sample pH to 7.8 which is not always possible.

    1 answer
    1. It is important to use correct pH-value. The luciferase reaction has its pH-optimum in the range of 7.75. Samples having extreme high pH-values or samples of a different pH containing high buffer concentrations may influence the light reaction in an unpredictable way. To avoid issues, correct the pH to a value between 7.6 and 8.0 or dilute samples in Tricine Buffer of the appropriate pH.

      Helpful?

  3. Can Product FLAA, ATP Bioluminescent Assay Kit assay mix be used on cells and tissues?

    1 answer
    1. This reagent measures only soluble ATP. Cells must be washed and then lysed to obtain a soluble ATP extract. Tissues must be homogenized and clarified to provide an extract. The supernatant solution can then be used for assay.

      Helpful?

  4. What is the sensitivity of Product FLAA, ATP Bioluminescent Assay Kit the assay mix?

    1 answer
    1. With FLAAM diluted 1:5, one can easily measure 1 pmol ATP in 100 μl (10 nM) with 50 μl of the reagent.

      Helpful?

  5. What  is the stability of the Product FLAA, ATP Bioluminescent Assay Kit ATP stock solution?

    1 answer
    1. The ATP standard stock solution (FLAAS) is stable for at least 24 hours at 0-5°C, or for over two weeks if stored frozen at -20°C.

      Helpful?

  6. How many reactions can one do with Product FLAA, ATP Bioluminescent Assay Kit (one vial of FLAAM)?

    1 answer
    1. When one reconstitutes the vial to 5 ml, as directed, one can perform 50 assays using 100 ul per test. If one dilutes 1:5 one can get 250 tests per kit.

      Helpful?

  7. How can one check for inhibitors in the samples when using Product FLAA, ATP Bioluminescent Assay Kit?

    1 answer
    1. One must add an amount of ATP from a standard solution equivalent to the ATP already found in the sample. If the signal is doubled, the absence of an inhibitor is indicated.

      Helpful?

  8. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters