Fontos dokumentumok
S9888
Sodium chloride
ACS reagent, ≥99.0%
Szinonimák:
Halite, NaCl
About This Item
Javasolt termékek
grade
ACS reagent
Minőségi szint
Ügynökség
suitable for EPA 1613
suitable for EPA 300
suitable for GB 5009.253-2016
gőznyomás
1.33 hPa ( 865 °C)
Teszt
≥99.0%
Forma
powder
szennyeződések
≤0.005% Insoluble matter
pH
5.0-9.0 (25 °C, 5% in solution)
mp
801 °C (lit.)
anion nyomok
bromide (Br-): ≤0.01%
chlorate, nitrate (as NO3-): ≤0.003%
iodide (I-): ≤0.002%
phosphate (PO43-): ≤5 ppm
sulfate (SO42-): ≤0.004%
kation nyomok
Ba:, passes test
Ca: ≤0.002%
Fe: ≤2 ppm
K: ≤0.005%
Mg: ≤0.001%
heavy metals: ≤5 ppm (by ICP-OES)
SMILES string
[Na+].[Cl-]
InChI
1S/ClH.Na/h1H;/q;+1/p-1
Nemzetközi kémiai azonosító kulcs
FAPWRFPIFSIZLT-UHFFFAOYSA-M
Looking for similar products? Látogasson el ide Útmutató a termékösszehasonlításhoz
Alkalmazás
Egyéb megjegyzések
Jogi információk
Tárolási osztály kódja
13 - Non Combustible Solids
WGK
WGK 1
Lobbanási pont (F)
Not applicable
Lobbanási pont (C)
Not applicable
Válasszon a legfrissebb verziók közül:
Analitikai tanúsítványok (COA)
Nem találja a megfelelő verziót?
Ha egy adott verzióra van szüksége, a tétel- vagy cikkszám alapján rákereshet egy adott tanúsítványra.
Már rendelkezik ezzel a termékkel?
Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.
Az ügyfelek ezeket is megtekintették
Cikkek
HPLC-UV method detects 9 antioxidants like propyl gallate in food using a Discovery®
Characterize mAb monomers, aggregates, and fragments using SEC-UV workflow with Zenix® and Zenix®-C SEC columns.
Using an Ascentis® Express F5 HPLC column, this study separates 11 β-agonists in pork by LC-MS/MS in under 8 minutes with excellent recovery and precision.
Protocols
Protocol for the preparation of Antibody Sensitized Sheep Erythrocytes. Includes product numbers and links.
SEC-MS protocol for rapid glycoprofiling of monoclonal antibodies with antibody purification and mass spectrometer calibration.
A complete workflow for the intact and middle-up mass analysis of reduced and non-reduced monoclonal antibodies based on SEC-MS with sample preparation by protein-A affinity clean-up.
Follow our procedure for the determination of alpha-Amylase activity. This enzymatic assay of a-Amylase guides you through the entire process and necessary calculations.
Related Content
This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.
Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.
Lépjen kapcsolatba a szaktanácsadással