Accéder au contenu
Merck
Toutes les photos(1)

Principaux documents

P4707

Sigma-Aldrich

Poly-ʟ-Lysine Hydrobromide

Poly-L-lysine solution

synthetic, liquid, 0.01%, suitable for cell culture

Synonyme(s) :

Solution de PLL

Se connecterpour consulter vos tarifs contractuels et ceux de votre entreprise/organisme


About This Item

Numéro CAS:
Numéro MDL:
Code UNSPSC :
12352202
eCl@ss :
32160406
Nomenclature NACRES :
NA.75
Le tarif et la disponibilité ne sont pas disponibles actuellement.

Nom du produit

Poly-L-lysine solution, 0.01%, sterile-filtered, BioReagent, suitable for cell culture

Source biologique

synthetic

Niveau de qualité

Stérilité

sterile-filtered

Gamme de produits

BioReagent

Forme

liquid

Poids mol.

70—150 kDa

Conditionnement

pkg of 50 mL

Concentration

0.01%

Technique(s)

cell culture | mammalian: suitable

Couverture de surface

4 μg/cm2

Impuretés

endotoxin, tested

Solubilité

water: soluble

Conditions d'expédition

ambient

Température de stockage

2-8°C

Chaîne SMILES 

N([C@@H](CCCCN)C(=O)N[C@@H](CCCCN)C(=O)O)C(=O)[C@@H](N)CCCCN

InChI

1S/C18H38N6O4/c19-10-4-1-7-13(22)16(25)23-14(8-2-5-11-20)17(26)24-15(18(27)28)9-3-6-12-21/h13-15H,1-12,19-22H2,(H,23,25)(H,24,26)(H,27,28)/t13-,14-,15-/m0/s1

Clé InChI

WBSCNDJQPKSPII-KKUMJFAQSA-N

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Description générale

La poly-L-lysine est un polymère d'acide aminé à charge positive, comportant environ un HBr par résidu de lysine. Le bromhydrate permet de former une poudre cristalline de poly-L-lysine soluble dans l'eau. Une petite quantité de produit peut être repliée en structure bêta, car HBr perturbe la formation de liaisons hydrogène entre les groupements amine et soit les groupements carboxyle soit les fractions contenant des atomes d'azote ou d'oxygène.

Application

  • Des lamelles de verre enduites de poly-L-lysine ont servi à monter des échantillons en vue d′une analyse par microscopie électronique à balayage.[1]
  • Des puits enduits de poly-L-lysine ont été utilisés pour piéger des cellules PC-12 sur des électrodes.[2]
  • Des lames de verre borosilicaté enduites de poly-L-lysine ont été employées pour l′ensemencement de cellules transduites avec un vecteur viral.[3]
Les polymères de poly-L-lysine peuvent être utilisés pour favoriser l'adhésion de cellules sur des substrats solides, la conjugaison au méthotrexate pour améliorer le transport du médicament, la microencapsulation des îlots de Langerhans, la technologie de microencapsulation de cellules, le revêtement de lames de verre et les préparations chromosomiques. La poly-L-lysine de faible poids moléculaire (30 000 à 70 000 Da) forme des solutions moins visqueuses, mais les versions de poids moléculaire supérieur offrent davantage de points d'attache par molécule.

Actions biochimiques/physiologiques

La poly-L-lysine est un facteur d'attachement cellulaire non spécifique qui favorise l'adhésion des cellules aux substrats solides en augmentant les interactions électrostatiques entre les ions chargés négativement de la membrane cellulaire et de la surface de culture. Lorsqu'elle est adsorbée sur la surface de culture, la poly-L-lysine augmente le nombre de sites chargés positivement disponibles pour l'adhésion des cellules. En présence de cellules capables de la dégrader, la poly-L-lysine doit être utilisée comme facteur d'attachement cellulaire.

Composants

La poly-L-lysine est un polymère d'acide aminé à charge positive, comportant environ un HBr par résidu de lysine. Le bromhydrate permet de former une poudre cristalline de poly-L-lysine soluble dans l'eau. Une petite quantité de produit peut être repliée en structure bêta, car HBr perturbe la formation de liaisons hydrogène entre les groupements amine et soit les groupements carboxyle soit les fractions contenant des atomes d'azote ou d'oxygène.

Notes préparatoires

Ce produit est fourni sous forme de solution stérilisée par filtration à 0,01 % dans l′eau. Après avoir enduit les lames de cette solution, incuber 5 minutes puis laisser sécher à température ambiante. Les lames enduites sont stables un an si elles sont protégées de la poussière.

Code de la classe de stockage

12 - Non Combustible Liquids

Classe de danger pour l'eau (WGK)

WGK 2

Point d'éclair (°F)

Not applicable

Point d'éclair (°C)

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

All polymer chip for amperometric studies of transmitter release from large groups of neuronal cells.
Larsen ST and Taboryski R
Analyst, 137, 5057-5057 (2012)
Microparticles mediate MRP1 intercellular transfer and the re-templating of intrinsic resistance pathways.
Lu JF et al.
Pharmacological Research, 76, 77-77 (2013)
Promiscuous dimerization of the growth hormone secretagogue receptor (GHS-R1a) attenuates ghrelin-mediated signaling.
Schellekens H et al.
The Journal of Biological Chemistry, 288, 181-181 (2013)
Peter T Jindra et al.
Biochemical and biophysical research communications, 369(2), 781-787 (2008-03-04)
The aim of this study was to characterize the interaction between mTOR and ERK in primary endothelial cells (EC) following MHC class I and integrin ligation. Ligation of MHC class I molecules or integrins on the surface of EC leads
M A G Rabbani et al.
Journal of virology, 90(24), 11145-11156 (2016-11-01)
A major arm of cellular innate immunity is type I interferon (IFN), represented by IFN-α and IFN-β. Type I IFN transcriptionally induces a large number of cellular genes, collectively known as IFN-stimulated gene (ISG) proteins, which act as antivirals. The

Articles

Poly-Lysine enhances cell binding with positively-charged surface ions, optimizing electrostatic interaction on culture surfaces for increased cell attachment.

Poly-Lysine enhances cell binding with positively-charged surface ions, optimizing electrostatic interaction on culture surfaces for increased cell attachment.

Poly-Lysine enhances cell binding with positively-charged surface ions, optimizing electrostatic interaction on culture surfaces for increased cell attachment.

Poly-Lysine enhances cell binding with positively-charged surface ions, optimizing electrostatic interaction on culture surfaces for increased cell attachment.

Afficher tout

Protocoles

Utilisation de poly-lysine pour faire adhérer les cellules à des substrats solides, augmentant ainsi les interactions électrostatiques entre les ions chargés négativement de la membrane cellulaire et de la surface de culture.

Utilisation de poly-lysine pour faire adhérer les cellules à des substrats solides, augmentant ainsi les interactions électrostatiques entre les ions chargés négativement de la membrane cellulaire et de la surface de culture.

Adhere cells to solid substrates using poly-lysine, which enhances electrostatic interaction between negatively charged ions of the cell membrane and the culture surface.

Utilisation de poly-lysine pour faire adhérer les cellules à des substrats solides, augmentant ainsi les interactions électrostatiques entre les ions chargés négativement de la membrane cellulaire et de la surface de culture.

Questions

1–10 of 12 Questions  
  1. When coating coverslips with item P4707, is it necessary to wash the reagent off after 5 minutes, or is there a different recommended procedure?

    1 answer
    1. The product is provided as a 0.01% sterile filtered solution in water. When coating slides with this solution, it is recommended to incubate for 5 minutes and allow the slides to dry at room temperature.

      Helpful?

  2. Is the product P4707 suitable for coating glassware for cell culture? Also, what is the difference between Poly L and Poly D lysine?

    1 answer
    1. Yes, the product P4707 is suitable for coating glassware for cell culture. The difference between Poly L and Poly D lysine lies in their stereoisomeric properties. Poly-L-Lysine is a charge enhancer and can be used for coating many surfaces, including tissue culture plasticware and glassware. However, certain cells can digest poly-L-lysine, in which case the poly-D-lysine, such as P7405, should be used. This product can also be used to coat tissue culture plasticware and glassware.

      Helpful?

  3. How many times can it be reused?

    1 answer
    1. The number of times that this product may be re-applied has not been determined. This would be dependent on several factors, such as surface area, material type, surface pretreatment, and incubation period. Please see the link below to review the product datasheet for additional information:
      https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/244/731/p4707pis.pdf

      Helpful?

  4. What is the molecular weight of product P4707?

    1 answer
    1. Poly-L-lysine solution is 70-150 kDa molecular weight.

      Helpful?

  5. Should I use Poly-L-Lysine or Poly-D-Lysine?

    1 answer
    1. Certain cells secrete proteases, which can digest poly-L-lysine. For those cell types, poly-D-lysine should be used.

      Helpful?

  6. How should I dilute Product P4707, Poly-L-Lysine solution?

    1 answer
    1. For coating slides with poly-L-lysine, in general, it is recommended to use a 0.01% (w/v) solution.  However, if your protocol requires a more dilute solution, you can add sterile water or sterile buffer like Phosphate Buffered Saline.

      Helpful?

  7. What is the concentration of Product P4707, Poly-L-Lysine solution?

    1 answer
    1. This product is supplied as a 0.01% w/v solution.

      Helpful?

  8. What is the protocol for using Product P4707, Poly-L-Lysine solution, to coat tissue culture plasticware?

    1 answer
    1. A solution of 0.1 mg/mL is prepared; 0.5 mL of that solution is aseptically transferred to a non-tissue culture treated 25 square cm flask. The flask is gently rocked to evenly coat the surface. After five minutes, the excess solution is removed and the surface is thoroughly rinsed with sterile water and allowed to dry for several hours.

      Helpful?

  9. What molecular weight Poly-L-Lysine product should I choose?

    1 answer
    1. The lower molecular weight poly-L-lysine (30-70 kDa) is easier to use because it is less viscous in solution, but the higher molecular weight poly-L-lysine (>300 kDa) provides more attachment sites per molecule. The mid-range product has a molecular weight range of 70-150 kDa.

      Helpful?

  10. What is the protocol for using Product P4707, Poly-L-Lysine solution, to coat slides?

    1 answer
    1. For coating slides with poly-L-lysine, in general, it is recommended to use a 0.01% (w/v) solution. After a 5 minute incubation, the excess solution is removed and the slides are dried at room temperature or in an oven at gentle heat.

      Helpful?

1–10 of 12 Questions  

Reviews

Active Filters

  1. 1 Ratings-Only Review

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique