Skip to Content
Merck

Skip To

S6322

Sigma Adjuvant System®

oil

Synonym(s):

Adjuvant System, Sigma Adjuvant

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice

About This Item

NACRES:
NA.46
UNSPSC Code:
12352203
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


form

oil

Quality Level

storage temp.

2-8°C

Application

Adjuvanticity Assay: EIA titer for test mice is at least 2X greater that that of control mice.

Biochem/physiol Actions

Sigma Adjuvant System is a stable oil-in-water emulsion that may be used as an alternative to the classical Freund′s water-in-oil emulsions. It is derived from bacterial and mycobacterial cell wall components that provide potent stimulus to the immune system.

Physical form

Each vial contains 0.5 mg Monophosphoryl Lipid A (detoxified endotoxin) from Salmonella minnesota and 0.5 mg synthetic Trehalose Dicorynomycolate in 2% oil (squalene)-Tween® 80-water.

Legal Information

Sigma Adjuvant System is a registered trademark of Merck KGaA, Darmstadt, Germany
TWEEN is a registered trademark of Croda International PLC

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
C5650SML0154F5506
storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

form

oil

form

oil

form

oil

form

liquid

Quality Level

300

Quality Level

200

Quality Level

100

Quality Level

300


pictograms

Health hazard

signalword

Danger

hcodes

Hazard Classifications

Asp. Tox. 1

Storage Class

10 - Combustible liquids

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, multi-purpose combination respirator cartridge (US)



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Development of monoclonal antibodies specific for Ricinus agglutinins
Brandon DL and Hernlem BJ
Food and agricultural immunology, 20(1), 11-22 (2009)
Nadja Thönes et al.
Journal of virology, 82(11), 5472-5485 (2008-04-04)
Capsomeres are considered to be an alternative to viruslike particle (VLP)-based vaccines as they can be produced in prokaryotic expression systems. So far, no detailed side-by-side comparison of VLPs and capsomeres has been performed. In the present study, we immunized
Christina Schellenbacher et al.
Journal of virology, 83(19), 10085-10095 (2009-07-31)
The amino (N) terminus of the human papillomavirus (HPV) minor capsid protein L2 can induce low-titer, cross-neutralizing antibodies. The aim of this study was to improve immunogenicity of L2 peptides by surface display on highly ordered, self-assembled virus-like particles (VLP)



Global Trade Item Number

SKUGTIN
S6322-1VL04061836957940

Questions

1–8 of 8 Questions  
  1. Is the adjuvant ready to use? I don't see any mention in the datasheet on how to prepare the Antigen:adjuvant mixture. Can you help with that? Thank you.

    1 answer
    1. This product requires dilution with saline prior to use. This dilution can be done with or without the addition of the antigen. See below for a brief protocol.

      Prior to antigen addition, warm contents of vial to 40-45 °C. Add 2.0 mL of sterile saline containing the desired amount of antigen.
      The final emulsion will contain a concentration of 2% oil.
      1. Inject antigen-saline solution (2 mL) directly into the vial through the rubber stopper using a syringe fitted with a 20 or 21-gauge needle (leave the cap seal in place).
      2. Vortex the vial vigorously for 2 to 3 minutes to form emulsion. Invert the vial and vortex for 1 minute to ensure reconstitution of any product adhering to the stopper.
      3. If the entire contents of the vial will not be used initially, reconstitute with 1 ml saline without antigen. This emulsion can be stored at 2-8 °C for up to 60 days. Do Not freeze.
      To use, mix aliquots 1:1 with antigen in saline.
      4. Prior to inoculation, warm the vial to 37 °C and vortex briefly.

      For full details on injection protocols and boosting, please navigate to the link https://www.sigmaaldrich.com/techservice, click on "Product Technical Inquiries" under the Products Section with all the required information so that a member of the Technical Service team can reach out to assist further. Thank you.

      Helpful?

  2. Can you reconstitute and store the Sigma Adjuvant System® reagent (Product No. S6322) if not using the entire vial right away?

    1 answer
    1. If the entire contents of the vial will not be used initially, reconstitute with 1 ml saline without antigen.  This emulsion can then be stored at 2-8 °C for up to 60 days.  Do Not Freeze. To use, mix aliquots 1:1 with antigen in saline. Prior to inoculation, warm the vial to 37 °C and vortex briefly.  This and other information can be found on the Sigma Adjuvant System® reagent (Product No. S6322) Product Information Sheet.

      Helpful?

  3. What is used to solubilize Product No. S6322, Sigma Adjuvant System® reagent?

    1 answer
    1. The Sigma Adjuvant System® reagent (Product No. S6322) can be solubilized in a sterile saline solution containing the desired amount of antigen to a final volume of 2 ml.  For more details, please see the S6322 Product Information Sheet.

      Helpful?

  4. Has Sigma Adjuvant System®, Product S6322, been used to induce EAE (Experimental autoimmune encephalomyelitis)?

    1 answer
    1. Sigma Adjuvant System®, Product S6322 is a replacement for MPT+TDM adjuvant (Ribi, Product M6536) that was discontinued by the supplier Corixa.  Although we have not tested Product S6322 for induction of Experimental autoimmune encephalomyelitis (EAE), the following reference cites the use of MBP in Ribi adjuvant for induction of acute EAE.The Journal of ImmunologyOctober 15, 2005, 175(8): 5077-5086

      Helpful?

  5. When using the Sigma Adjuvant System®, Product No. S6322, how is the antigenic response boosted?

    1 answer
    1. With the Sigma Adjuvant System® (Product No. S6322) with mice, rabbits, rats and guinea pigs; boost on day 21 or 28, bleed 10 - 14 days after booster injection. Boost every 3 - 4 weeks thereafter. For goats; boost every four weeks. Use the same protocol for each injection.  For more information please see the Product Information Sheet for Product No. S6322.

      Helpful?

  6. Is the Sigma Adjuvant System®, Product No S6322, the same as the RIBI adjuvant?

    1 answer
    1. Yes, the Sigma Adjuvant System®, Product No S6322, is also called RIBI adjuvant.

      Helpful?

  7. When using the Sigma Adjuvant System® reagent, Product No. S6322, how do the components MPL and TDM work as an adjuvant?

    1 answer
    1. MPL (monophosphoryl lipid A) will bind to CD14 on the cell surface similar to LPS.  TDM (trehalose dicorynomycolate) is an analog of one of the components of the tubercle bacillus. Both of these components act like a superantigen and activate the immune system nonspecifically.  This allows for a greater response to the immunogen delivered in this adjuvant.

      Helpful?

  8. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

No rating value

Active Filters