Skip to Content
Merck

Skip To

1.16127

Lactic Acid Test Strips, reflectometric

3.0-60.0 mg/L (lactic acid), REFLECTOQUANT®, for use with RQflex® 20

Synonym(s):

Lactic Acid chemical test strips, Lactic Acid test strip for instrument reader

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice

About This Item

UNSPSC Code:
41116116
NACRES:
NA.24
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Lactic Acid Test, reflectometric, 3.0-60.0 mg/L (lactic acid), for use with REFLECTOQUANT®

description

quantitative

Quality Level

specific analyte(s)

lactic acid

reaction suitability

reaction type: enzymatic reaction

measuring range

3.0-60.0 mg/L (lactic acid)

application(s)

beverage testing
food testing
milk and dairy products

compatibility

RQflex® 20, for use with REFLECTOQUANT®

detection method

reflectometric

storage temp.

2-8°C

General description

Method: reflectometric with test strips 3.0 - 60.0 mg/l Reflectoquant®
The Reflectoquant Lactic acid test measures total lactic acid (sum of D- and L-lactic acid in beverages, e.g. wine, beer and fruit/vegetable juice after dilution. Furthermore the test can be used for the determination of lactic acid in food after pretreatment. Lactic acid (lactate) is oxidized by nicotinamide adenine dinucleotide (NAD) under the catalytic effect of lactate dehydrogenase to a pyruvate. In the presence of diaphorase, the NADH formed in the process reduces a tetrazolium salt to a blue formazan that is determined reflectometrically on the RQflex® 20.

Analysis Note

function control: entspricht
Assay
- standard 1:
4.5 - 5.5 mg/l
- standard 2: 22.5 - 27.5 mg/l
- standard 3: 45.0 - 55.0 mg/l

Legal Information

REFLECTOQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
RQFLEX is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
1.169811.169761.16128
detection method

reflectometric

detection method

reflectometric

detection method

reflectometric

detection method

reflectometric

specific analyte(s)

lactic acid

specific analyte(s)

ascorbic acid

specific analyte(s)

peracetic acid

specific analyte(s)

malic acid

reaction suitability

reaction type: enzymatic reaction

reaction suitability

-

reaction suitability

reaction type: Redox Reactions

reaction suitability

reaction type: enzymatic reaction

compatibility

RQflex® 20, for use with REFLECTOQUANT®

compatibility

RQflex® 20, for use with REFLECTOQUANT®

compatibility

RQflex® 20, for use with REFLECTOQUANT®

compatibility

RQflex® 20, for use with REFLECTOQUANT®

application(s)

beverage testing
food testing
milk and dairy products

application(s)

beverage testing
food testing
milk and dairy products

application(s)

disinfection control

application(s)

beverage testing
food testing

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C

storage temp.

2-8°C


Storage Class

11 - Combustible Solids

wgk

WGK 2



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library





Global Trade Item Number

SKUGTIN
116127000104027269000905

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters