Pular para o conteúdo
Merck

Analysis of the chloroacetanilide herbicides in water using SPME with CAR/PDMS and GC/ECD.

Journal of AOAC International (2005-09-13)
Ying-Ming Hwang, Yih-Gang Wong, Wu-Hsiung Ho
RESUMO

The solid-phase microextraction (SPME) technique using a 75 mm film of carboxen/polydimethylsiloxane was applied to the analysis of chloroacetanilide herbicides (acetochlor, alachlor, butachlor, metolachlor, and propachlor) residues. The feasibility of SPME with gas chromatography electron capture detection analysis has been evaluated. The effects of experimental parameters such as magnetic stirring, salt addition, humic acid addition, pH value, and extraction time, as well as desorption temperature and time, were investigated. Analytical parameters such as linearity, repeatability and limit of detection were also evaluated. The inhibition of humic acid to the extraction of chloroacetanilide herbicides was observed. A standard addition method for calibration was recommended to reduce deviations caused by matrix interferences. The proposed method provided a simple and rapid analytical procedure for chloroacetanilide herbicides in water with limits of detection 0.002-0.065 microg/L for deionized water, and 0.005-0.22 microg/L for farm water. The relative standard deviations (n = 5) for analyses of farm water were 7-20% for 5 [corrected] microg/L chloroacetanilide herbicides. This application was illustrated by the analysis of sample collected from farm water in the Chung-hwa area, Taiwan.

MATERIAIS
Número do produto
Marca
Descrição do produto

Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 24 ga, StableFlex
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 24 ga, for use with manual holder
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with autosampler
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 23 ga, StableFlex, for use with manual holder or autosampler, fiber L 2 cm
Supelco
ORBO 90 Carboxen® 564 (20/45), 160/80 mg, W,F,F separators, O.D. × L 6 mm × 75 mm, pkg of 25 ea, for analyte group MEK (methylethyl ketone)
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), needle size 24 ga, StableFlex, for use with autosampler
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, for use with manual holder, needle size 24 ga
Supelco
Adsorvente Carboxen®, matrix Carboxen® 1000, 60-80 mesh, bottle of 10 g
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
ORBO 78 HBr on Carboxen® 564 specially cleaned (20/45), 400/200 mg, W,W,W separators, O.D. × L 6 mm × 110 mm, pkg of 25 ea
Supelco
Coluna de GC capilar Carboxen®-1006 PLOT, L × I.D. 30 m × 0.53 mm, average thickness 30 μm
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 23 ga, StableFlex, for use with autosampler
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 24 ga, for use with autosampler
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, StableFlex, for use with autosampler
Supelco
Carboxen®-1010 PLOT Capillary GC Column, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 85 μm(CAR/PDMS, needle size 24 ga, for use with manual holder, StableFlex fiber
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with autosampler
Supelco
Conjunto de fibras de SPME Carboxeno/polidimetilsiloxano (CAR/PDMS), df 75 μm(CAR/PDMS, needle size 23 ga, for use with manual holder
Supelco
Coluna de GC capilar Carboxen®-1006 PLOT, L × I.D. 30 m × 0.32 mm, average thickness 15 μm
Supelco
Adsorvente Carboxen®, matrix Carboxen® 572, 20-45 mesh, bottle of 10 g
Supelco
Tenax® TA / Carboxen® 1018, glass TD tube, preconditioned, O.D. × L 1/4 in. × 3 1/2 in., Sealed with (Swagelok® End-Fittings), pkg of 10 ea
Supelco
Carboxen® 1000 Reversible SPE Tube, 200 mg/mL, pk 30
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 2 cm
Supelco
Adsorvente Carboxen®, matrix Carboxen® 1000, 40-60 mesh, bottle of 50 g
Supelco
Adsorvente Carboxen®, matrix Carboxen® 1003, 40-60 mesh, bottle of 10 g
Supelco
Adsorvente Carboxen®, matrix Carboxen® 569, 20-45 mesh, bottle of 10 g
Supelco
ORBO-93 Sorbent Tube, ORBO tube I.D. × L 6 mm × 95 mm, Bed A 180 mg, Bed B 90 mg, 60/80 mesh, pkg of 25 ea
Supelco
Conjunto de fibras para SPME de divinilbenzeno-carboxeno-polidimetilsiloxano (DVB/CAR/PDMS), for use with autosampler, needle size 23 ga, metal alloy fiber, fiber L 1 cm
Supelco
Adsorvente Carboxen®, matrix Carboxen® 569, 20-45 mesh, bottle of 500 g
Supelco
Carboxen® 572 for Tobacco Smoke, Adsorbent Bed Wt: 300 mg, cartridge size 3 mL, pkg of 50 ea