Pular para o conteúdo
Merck
Todas as fotos(1)

Documentos Principais

25467

Supelco

Carboxen®-1010 PLOT Capillary GC Column

Carboxen®-1010 PLOT Capillary GC Column

L × I.D. 30 m × 0.53 mm, average thickness 30 μm

Sinônimo(s):

Carboxen® 1010 PLOT Column, 30m x 0.53mm

Faça loginpara ver os preços organizacionais e de contrato


About This Item

Número CE:
Código UNSPSC:
41115710
eCl@ss:
32119290
Preço e disponibilidade não estão disponíveis no momento.

Materiais

fused silica

Agency

ASTM® D3612-96

descrição

PLOT = Porous Layer Open Tubular

fabricante/nome comercial

Carboxen®

Parâmetros

≤25-250 °C temperature (isothermal or programmed)

espessura média

30 μm

df

30 μm

técnica(s)

gas chromatography (GC): suitable

C × D.I.

30 m × 0.53 mm

Grupo ativo da matriz

Carbon molecular sieve phase

aplicação(ões)

chemicals and industrial polymers
food and beverages

tipo de coluna

capillary PLOT

Procurando produtos similares? Visita Guia de comparação de produtos

Descrição geral

Application: This column is ideal for the separation of all major components in permanent gas (helium, hydrogen, oxygen, nitrogen, carbon monoxide, methane, and carbon dioxide) and light hydrocarbons (C2-C3) in the same analysis. It is the only column commercially available that is able to separate all major components in permanent gas. This column can also separate oxygen from nitrogen at subambient temperatures.
USP Code: None
Phase:
  • Carbon molecular sieve
Temp. Limits:
  • Subambient to 250 °C (isothermal or programmed)
Carboxen® Adsorbent is ideally used for solid-phase microextraction (SPME)[1] and does highly efficient extraction of small polar molecules from aqueous solution.[2] Porous-layer open-tubular (PLOT) columns are a powerful tool employed in gas chromatography during analysis of fixed gases, light hydrocarbons and volatile solvents. They are mostly preferred over traditional packed columns.[3]

Outras notas

We offer a variety of chromatography accessories including analytical syringes

Informações legais

ASTM is a registered trademark of American Society for Testing and Materials
Carboxen is a registered trademark of Merck KGaA, Darmstadt, Germany

Aplicação


Escolha uma das versões mais recentes:

Certificados de análise (COA)

Lot/Batch Number

Não está vendo a versão correta?

Se precisar de uma versão específica, você pode procurar um certificado específico pelo número do lote ou da remessa.

Já possui este produto?

Encontre a documentação dos produtos que você adquiriu recentemente na biblioteca de documentos.

Visite a Biblioteca de Documentos

Os clientes também visualizaram

Slide 1 of 4

1 of 4

Applications of Solid Phase Microextraction
Pawliszyn J.
Applications of Solid Phase Microextraction, 64-65 (1999)
Porous layer open-tubular capillary columns: preparations, applications and future directions.
Zhenghua Ji
Journal of Chromatography A, 842 (1), 115-142 (1999)
Louise Urruty et al.
Journal of agricultural and food chemistry, 50(11), 3129-3136 (2002-05-16)
To provide an efficient and running analytical tool to strawberry plant breeders who have to characterize and compare the aromatic properties of new cultivars to those already known, a HS-SPME/GC-MS analysis method has been coupled with a statistical treatment method
Noushin Rastkari et al.
Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, 877(14-15), 1568-1574 (2009-04-28)
Carbon nanotubes (CNTs) are a kind of new carbon-based nano-materials which have drawn great attention in many application fields. The potential single-walled carbon nanotubes (SWCNTs) as solid-phase microextraction (SPME) adsorbents for the preconcentration of environmental pollutants have been investigated in
Julien Januszkiewicz et al.
Journal of chromatography. A, 1195(1-2), 16-24 (2008-05-23)
A headspace solid-phase microextraction (HS-SPME) combined with gas chromatography-mass spectrometry (GC/MS) method was developed using experimental designs to quantify the flavor of commercial Cheddar cheese and enzyme-modified Cheddar cheese (EMCC). Seven target compounds (dimethyl disulfide, hexanal, hexanol, 2-heptanone, ethyl hexanoate

Questions

1–9 of 9 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What are the specific functional groups that may affect the separation and the carbon saturated/unsaturated ratio of the material used in the Carboxen 1010 PLOT capillary column?

    1 answer
    1. The material used in the Carboxen 1010 PLOT capillary column does not retain any functional groups after the synthesis process due to the high temperatures involved. The carbon surface consists mainly of carbon and hydrogen, with very few exceptions.

      Helpful?

  4. Are there specific installation instructions available for the Carboxen-1010 plot column 24246, particularly regarding whether it needs to be baked out before use?

    1 answer
    1. The installation of capillary columns can differ based on the gas chromatography brand, detector type, injection port, and insertion distance. It's advisable to consult the GC manual for column insertion distance information and any special adapters required before installation.

      Helpful?

  5. Is the Carboxen 1010 PLOT column, Product 25467, GC/MS compatible?

    1 answer
    1. Yes, the particles are very strongly adhered to the surface of the column and would be compatible with mass spec detection.

      Helpful?

  6. What is the film thickness of the Carboxen™-1010 PLOT Capillary GC Column, Product 25467?

    1 answer
    1. The film thickness for this column is 30um.  The term "film" is somewhat of a misnomer because it is actually a layer of solid carboxen particles adhered to the fused silica tubing.

      Helpful?

  7. How can I purchase a column that is packed with this material?

    1 answer
    1. Most packed column are custom made and require that you obtain a quotation. Please contact our Customer & Sales Services group at phone number (800)-247-6628, fax number (800)-447-3044 or email [email protected] for additional information.

      Helpful?

  8. What types of compounds would be suitable for analysis on the Carboxen™-1010 PLOT Capillary GC Column, Product 25467?

    1 answer
    1. This column is designed for the analysis of permanent gases and light hydrocarbons up to a maximum of 3 carbon units.

      Helpful?

  9. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

Reviews

Active Filters

  1. Sydney, Australia
    • Review 1
    • Votes 0
    5 out of 5 stars.

    Carboxen®-1010 PLOT Capillary GC Column

    Having used another similar column (different manufacturer) for the separation of H2, CO, CO2 and ethylene, I find this column to exhibit very good stability and reliability. Certainly, the high operational temperature rating is most welcomed.

    Helpful?

Nossa equipe de cientistas tem experiência em todas as áreas de pesquisa, incluindo Life Sciences, ciência de materiais, síntese química, cromatografia, química analítica e muitas outras.

Entre em contato com a assistência técnica