Direkt zum Inhalt
Merck

11024AST

Supelco

Astec® CHIROBIOTIC® V Chiral (5 μm) HPLC Columns

L × I.D. 25 cm × 4.6 mm, HPLC Column

Synonym(e):

V chirale stationäre Phasensäule

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

UNSPSC-Code:
41115700
eCl@ss:
32110501
NACRES:
SB.52
Preise und Verfügbarkeit sind derzeit nicht verfügbar.

Produktbezeichnung

Astec® CHIROBIOTIC® V Chirale HPLC-Säule, 5 μm particle size, L × I.D. 25 cm × 4.6 mm

Materialien

stainless steel column

Agentur

suitable for USP L88

Beschreibung

HPLC Column

Produktlinie

Astec®

Verpackung

pkg of 1 ea

Hersteller/Markenname

Astec®

Parameter

0-45 °C temperature
241 bar pressure (3500 psi)

Methode(n)

HPLC: suitable
LC/MS: suitable

L × ID

25 cm × 4.6 mm

Matrix

High-purity silica gel particle platform
fully porous particle

Aktive Matrixgruppe

vancomycin phase

Partikelgröße

5 μm

Porengröße

100 Å

pH Betriebsbereich

3.5-7.0

Trenntechnik

chiral

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Neutrale Moleküle, Amide, Säuren, Ester und Amine weisen auf diesen vancomycinbasierten CSPs eine signifikante Enantioselektivität auf. Eine breite Vielfalt von sekundären und tertiären Aminen wurde im polaren ionischen Modus auf der CHIROBIOTIC® V getrennt. Die CHIROBIOTIC® V hat viele der Trenneigenschaften von proteinbasierten stationären Phasen demonstriert, aber mit außergewöhnlicher Stabilität und einer deutlich höheren Probenkapazität. Bestimmte chirale Analyten, die in keinen anderen chiralen stationären Phasen als getrennt beschrieben wurden, wurden getrennt. CHIROBIOTIC® V und V2 unterscheiden sich hinsichtlich ihrer Bindungschemie und der Porengröße des Trägerpartikels, was ihnen eine unterschiedliche Selektivität und präparative Kapazität verleiht.

  • Gebundene Phase: Vancomycin
  • pH-Betriebsbereich: 3,5 - 7,0
  • Partikeldurchmesser: 5, 10 oder 16 μm
  • Porengröße: 100 Å (CHIROBIOTIC® V) oder 200 Å (CHIROBIOTIC® V2)

Anwendung

Die chirale HPLC-Säule Astec® CHIROBIOTIC® V eignet sich für die Trennung verschiedener Arten von racemischen Verbindungen (ß-Blocker, ß-Agonisten, Benzodiazepine, nicht-steroidale Entzündungshemmer, Barbiturate, freie und derivatisierte Aminosäuren in der subkritischen Flüssigchromatographie mit gepackten Säulen (pSFC)).[1] Sie kann in Humanplasma unter Verwendung der chiralen Flüssigchromatographie auch für die Trennung von Citalopram-Enantiomeren und ihrer zwei N-demethylierten Metaboliten und von Alprenolol – dem internen Standard – verwendet werden.[2] Sie kann darüber hinaus auch bei der chiralen Flüssigchromatographie-Analyse von Ketoprofen and Flurbiprofen verwendet werden.[3]

Empfohlene Produkte

LiChropur-Reagenzien eignen sich ideal für die HPLC- oder LC-MS-Analyse

Rechtliche Hinweise

Astec is a registered trademark of Merck KGaA, Darmstadt, Germany
CHIROBIOTIC is a registered trademark of Sigma-Aldrich Co. LLC

Anwendung

Produkt-Nr.
Beschreibung
Preisangaben

Lagerklassenschlüssel

11 - Combustible Solids

WGK

WGK 3

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

F Péhourcq et al.
Biomedical chromatography : BMC, 15(3), 217-222 (2001-06-08)
Vancomycin is an amphoteric, glycopeptide, macrocyclic antibiotic. When attached to 5 microspherical silica gel, vancomycin proved to be an effective chromatographic chiral stationary phase that could be used in the reversed-phase mode. In this study, a bonded vancomycin chiral stationary
Chiral packed column subcritical fluid chromatography on polysaccharide and macrocyclic antibiotic chiral stationary phases.
Andrei M
Journal of Chromatography A, 785 (1), 159-171 (1997)
M Kosel et al.
Journal of chromatography. B, Biomedical sciences and applications, 719(1-2), 234-238 (1998-12-30)
A procedure using a chirobiotic V column is presented which allows separation of the enantiomers of citalopram and its two N-demethylated metabolites, and of the internal standard, alprenolol, in human plasma. Citalopram, demethylcitalopram and didemethylcitalopram, as well as the internal
Sherri L MacLeod et al.
Journal of chromatography. A, 1170(1-2), 23-33 (2007-10-05)
A reversed-phase enantioselective liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) method was developed to measure enantiomer fractions (EF) and concentrations of pharmaceuticals in wastewater. Enantiomer resolution of six beta-blockers (atenolol, metoprolol, nadolol, pindolol, propranolol, and sotalol) along with two selective serotonin re-uptake
Hisham Hashem et al.
Journal of chromatography. A, 1218(38), 6727-6731 (2011-08-23)
In this study, a method for enantioseparation of terbutaline and salbutamol was established using Chirobiotic V column as a stationary phase. Polar ionic mode applying mobile phase containing ammonium nitrate in 100% ethanol, pH 5.1 was found to give the

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. What solvent to use for storage? Where can I download the user manual?

    1 answer
    1. Methanol is the recommended solvent for flushing and storage. The data sheet for this column is included with it upon shipment. A digital version can be obtained by contacting technical service.

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.