コンテンツへスキップ
Merck
  • A sensitive and accurate quantitative method to determine N-arachidonoyldopamine and N-oleoyldopamine in the mouse striatum using column-switching LC-MS-MS: use of a surrogate matrix to quantify endogenous compounds.

A sensitive and accurate quantitative method to determine N-arachidonoyldopamine and N-oleoyldopamine in the mouse striatum using column-switching LC-MS-MS: use of a surrogate matrix to quantify endogenous compounds.

Analytical and bioanalytical chemistry (2014-05-13)
Dajeong Ji, Choon-Gon Jang, Sooyeun Lee
要旨

The transient receptor potential vanilloid 1 (TRPV1) channel, a nonselective Ca(2+) and Na(+) channel, is a molecular transducer of nociceptive stimuli. N-Arachidonoyl dopamine (NADA) and N-oleoyldopamine (OLDA), two unsaturated N-acyldopamines, are major activating endogenous TRPV1 ligands and their presence in mammalian brain tissue has been reported. However, the biological significance of NADA and OLDA remains unknown. To investigate their biological function in the nervous system, a sensitive and accurate quantitative method for determining endogenous NADA and OLDA in the brain is necessary. Thus, a column-switching liquid chromatography-tandem mass spectrometry (LC-MS-MS) method was developed to quantify NADA and OLDA in mouse striatum. Mouse cerebellum tissue in which neither NADA nor OLDA were detected was used as a surrogate matrix to prepare calibrators. NADA and OLDA were extracted from mouse brain tissue by solid-phase extraction and then filtered and analyzed by LC-MS-MS with electrospray ionization in the positive ion mode. The selectivity results and comparison of calibration curves prepared with mouse cerebellum and striatum established that the former was acceptable as the surrogate matrix of the latter for analyzing NADA and OLDA. The validation results of the matrix effect, linearity, precision, accuracy, and stability were satisfactory. The limits of detection and limits of quantification were 0.125 pg mg(-1) for both analytes. This method was sensitive and accurate enough to determine endogenous concentrations of these compounds in mouse striatum and will be very useful for further study of the biological functions of NADA and OLDA and other related factors in vivo.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, suitable for HPLC, ≥99.9%
Sigma-Aldrich
トリフルオロ酢酸, ReagentPlus®, 99%
Sigma-Aldrich
トリフルオロ酢酸, suitable for HPLC, ≥99.0%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, HPLC Plus, ≥99.9%
Sigma-Aldrich
トリフルオロ酢酸, puriss. p.a., suitable for HPLC, ≥99.0% (GC)
Sigma-Aldrich
アセトニトリル, ACS reagent, ≥99.5%
Sigma-Aldrich
アセトニトリル, ≥99.9% (GC)
Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
フェニルメチルスルホニルフルオリド, ≥98.5% (GC)
Sigma-Aldrich
メタノール, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
メタノール, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
トリフルオロ酢酸, ≥99%, for protein sequencing
Sigma-Aldrich
メタノール, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
アセトニトリル, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタノール, BioReagent, ≥99.93%
Sigma-Aldrich
メタノール, Absolute - Acetone free
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
Sigma-Aldrich
フェニルメチルスルホニルフルオリド, ≥99.0% (T)
USP
メチルアルコール, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
アセトニトリル, biotech. grade, ≥99.93%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
メタノール, puriss., meets analytical specification of Ph Eur, ≥99.7% (GC)