Ugrás a tartalomra
Merck

SAE0059

Sigma-Aldrich

OxyFluor

Szinonimák:

OF

Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez


About This Item

UNSPSC kód:
41106212
NACRES:
NA.54

Minőségi szint

tárolási hőmérséklet

−20°C

Alkalmazás

The Oxyrase® Enzyme System in OxyFluor removes dissolved oxygen effectively and efficiently. This significantly reduces or eliminates the formation of oxygen free radicals under conditions employed for fluorescent microscopy and results in brighter cell images. OxyFluor provides a protective effect for the biological material being studied and is an excellent solution for live cell imaging and cell culture applications.

Biokémiai/fiziológiai hatások

OxyFluor is used at a 1:100 dilution. Lactate is a convenient substrate at 10 mM to 20 mM concentration.

Egyéb megjegyzések

There are no reports of Oxyrase® having an adverse effect on biological systems. Oxyrase® does not produce toxic compounds in the course of reducing oxygen to water.

Jogi információk

OxyFluor is a trademark of Oxyrase, Inc.
Oxyrase is a registered trademark of Oxyrase, Inc.

Tárolási osztály kódja

12 - Non Combustible Liquids

WGK

WGK 2

Lobbanási pont (F)

Not applicable

Lobbanási pont (C)

Not applicable


Analitikai tanúsítványok (COA)

Analitikai tanúsítványok (COA) keresése a termék sarzs-/tételszámának megadásával. A sarzs- és tételszámok a termék címkéjén találhatók, a „Lot” vagy „Batch” szavak után.

Már rendelkezik ezzel a termékkel?

Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.

Dokumentumtár megtekintése

Elias Nehme et al.
Nature methods, 17(7), 734-740 (2020-06-17)
An outstanding challenge in single-molecule localization microscopy is the accurate and precise localization of individual point emitters in three dimensions in densely labeled samples. One established approach for three-dimensional single-molecule localization is point-spread-function (PSF) engineering, in which the PSF is
Boris Ferdman et al.
Optics express, 28(7), 10179-10198 (2020-04-01)
In microscopy, proper modeling of the image formation has a substantial effect on the precision and accuracy in localization experiments and facilitates the correction of aberrations in adaptive optics experiments. The observed images are subject to polarization effects, refractive index
Pernille Bülow et al.
Frontiers in cell and developmental biology, 9, 702020-702020 (2021-08-06)
Mitochondrial dysfunction has long been overlooked in neurodevelopmental disorders, but recent studies have provided new links to genetic forms of autism, including Rett syndrome and fragile X syndrome (FXS). Mitochondria show plasticity in morphology and function in response to neuronal

Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.

Lépjen kapcsolatba a szaktanácsadással