E-060
17β-Estradiol solution
1.0 mg/mL in acetonitrile, ampule of 1 mL, certified reference material, Cerilliant®
About This Item
Javasolt termékek
grade
certified reference material
Minőségi szint
form
liquid
Jellemzők
Snap-N-Spike®/Snap-N-Shoot®
kiszerelés
ampule of 1 mL
gyártó/kereskedő neve
Cerilliant®
koncentráció
1.0 mg/mL in acetonitrile
technika/technikák
gas chromatography (GC): suitable
liquid chromatography (LC): suitable
alkalmazás(ok)
clinical testing
clinical testing
format
single component solution
tárolási hőmérséklet
2-8°C
SMILES string
CC12CCC3C(CCc4cc(O)ccc34)C1CCC2O
InChI
1S/C18H24O2/c1-18-9-8-14-13-5-3-12(19)10-11(13)2-4-15(14)16(18)6-7-17(18)20/h3,5,10,14-17,19-20H,2,4,6-9H2,1H3/t14-,15-,16+,17+,18+/m1/s1
Nemzetközi kémiai azonosító kulcs
VOXZDWNPVJITMN-ZBRFXRBCSA-N
Géninformáció
human ... ESR1(2099)
Általános leírás
17β-Estradiol belongs to the group of endogenous endocrine disruptors that disturb thyroid activity and function. It is also a sex hormone prescribed under the trade names Vagifem®, Estring®, Evamist, Elestrin®, Estrace®, and Estrogel® as a treatment for hypoestrogenism.
Alkalmazás
- Electrochemical determination of 17β-Estradiol in river water samples using a reduced graphene oxide and a metal complex porphyrin-based sensor
- Development of a fluorescence resonance energy transfer (FRET) based aptasensor to determine 17β-Estradiol in environmental water, urine, and milk samples
- Analysis of milk product samples to estimate 17β-Estradiol by high-performance liquid chromatography (HPLC) coupled with fluorescence detection following its solid phase extraction using graphene/multi-walled carbon nanotubes (MWCNTs)
- Solid phase extraction of 17β-estradiol and 17α-ethinylestradiol from tap water samples using magnetic graphene oxide (GO)/γ-Fe2O3 nanoparticles for their simultaneous quantification by high-performance liquid chromatography (HPLC) combined with fluorescence detector
- Multi-residue analysis of 17β-estradiol and 17α-ethinylestradiol in commercial pharmaceutical formulation and urine samples using hanging mercury drop electrode and screen printed carbon electrode
Tulajdonságok és előnyök
- Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
- Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
- Rigorously tested through real-time stability studies to ensure accuracy and shelf life
- Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
- Flame sealed under argon into ampoules for long-term shelf life
- Offered in a convenient, DEA-exempt format to improve laboratory efficiency
Jogi információk
kapcsolódó termék
Figyelmeztetés
Danger
Figyelmeztető mondatok
Óvintézkedésre vonatkozó mondatok
Veszélyességi osztályok
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2
Tárolási osztály kódja
3 - Flammable liquids
WGK
WGK 2
Lobbanási pont (F)
35.6 °F - closed cup
Lobbanási pont (C)
2 °C - closed cup
Analitikai tanúsítványok (COA)
Analitikai tanúsítványok (COA) keresése a termék sarzs-/tételszámának megadásával. A sarzs- és tételszámok a termék címkéjén találhatók, a „Lot” vagy „Batch” szavak után.
Már rendelkezik ezzel a termékkel?
Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.
Az ügyfelek ezeket is megtekintették
Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.
Lépjen kapcsolatba a szaktanácsadással