Teszt
99%
Forma
liquid
törésmutató
n20/D 1.501 (lit.)
bp
229.5 °C/766 mmHg (lit.)
sűrűség
1.026 g/mL at 25 °C (lit.)
funkcionális csoport
ester
phenyl
SMILES string
CCCOC(=O)c1ccccc1
InChI
1S/C10H12O2/c1-2-8-12-10(11)9-6-4-3-5-7-9/h3-7H,2,8H2,1H3
Nemzetközi kémiai azonosító kulcs
UDEWPOVQBGFNGE-UHFFFAOYSA-N
Looking for similar products? Látogasson el ide Útmutató a termékösszehasonlításhoz
Általános leírás
The adsorption data of propyl benzoate was obtained by frontal analysis on a symmetry-C18 column by a mixture of methanol and water as the mobile phase.
Alkalmazás
Propyl benzoate was used to extract desipramine, a model compound used in the electrochemical analysis by a combined hollow fiber-based liquid three-phase microextraction and voltammetric method.
Figyelmeztetés
Warning
Figyelmeztető mondatok
Óvintézkedésre vonatkozó mondatok
Veszélyességi osztályok
Eye Irrit. 2 - Skin Irrit. 2
Tárolási osztály kódja
10 - Combustible liquids
WGK
WGK 3
Lobbanási pont (F)
>212.0 °F
Lobbanási pont (C)
> 100 °C
Egyéni védőeszköz
Eyeshields, Gloves
Válasszon a legfrissebb verziók közül:
Már rendelkezik ezzel a termékkel?
Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.
Az ügyfelek ezeket is megtekintették
Talanta, 82(4), 1588-1593 (2010-08-31)
In this paper, a combined hollow fiber-based liquid three-phase microextraction and voltammetric method are applied for the first time as a highly selective and sensitive method of electrochemical analysis. Desipramine, used as a model compound was extracted from 8 mL
Journal of chromatography. A, 1069(1), 31-42 (2005-04-23)
The adsorption data of propyl benzoate were acquired by frontal analysis (FA) on a Symmetry-C18 column, using a mixture of methanol (65%, v/v) and water as the mobile phase, at three different flow rates, 0.5, 1.0 and 2.0 mL/min. The
European journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences, 109, 280-287 (2017-08-20)
We studied the effect that three alcohols, ethanol (EA), propanol (PA), and isopropanol (IPA), have on the skin permeation of p-hydroxy benzoic acid methyl ester (HBM), a model ester-type prodrug. HBM was applied to Yucatan micropig skin in a saturated
Journal of chromatography. A, 1479, 194-203 (2016-12-14)
Liposomes were used as biomimetic models in capillary electrokinetic chromatography (EKC) for the determination of distribution constants (K
Electrophoresis, 37(2), 363-371 (2015-10-16)
The use of bare fused silica capillary in CE can sometimes be inconvenient due to undesirable effects including adsorption of sample or instability of the EOF. This can often be avoided by coating the inner surface of the capillary. In
Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.
Lépjen kapcsolatba a szaktanácsadással