Direkt zum Inhalt
Merck

14211

Supelco

Wasser

ACS reagent, CHROMASOLV®, suitable for HPLC and ultratrace analysis

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

1 L
€ 200,00

€ 200,00


Check Cart for Availability

Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
1 L
€ 200,00

About This Item

Lineare Formel:
H2O
CAS-Nummer:
Molekulargewicht:
18.02
Beilstein:
2050024
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
12191602
PubChem Substanz-ID:
NACRES:
NA.24
bp:
100 °C (lit.)

€ 200,00


Check Cart for Availability

Bulk-Bestellung anfordern

Produktbezeichnung

Wasser, for inorganic trace analysis, ACS reagent, for ultratrace analysis

Qualität

ACS reagent
for inorganic trace analysis

Qualitätsniveau

Form

liquid

Methode(n)

immunofluorescence: suitable

Verunreinigungen

≤5 μg/kg ammonium (NH4)

Brechungsindex

n20/D 1.34 (lit.)

pH-Wert

6.0-8.0(-25 °C77 °F)

bp

100 °C (lit.)

mp (Schmelzpunkt)

0 °C (lit.)

Löslichkeit

water: miscible (completely)

Dichte

1.000 g/mL at 3.98 °C (lit.)

Anionenspuren

bromide (Br-): ≤1 μg/kg
chloride (Cl-): ≤1 μg/kg
fluoride (F-): ≤1 μg/kg
iodide (I-): ≤1 μg/kg
nitrate (NO3-): ≤1 μg/kg
nitrite (NO2-): ≤1 μg/kg
phosphate (PO43-): ≤1 μg/kg
sulfate (SO42-): ≤1 μg/kg

Kationenspuren

Ag: ≤0.001 μg/kg
Al: ≤0.5 μg/kg
As: ≤0.01 μg/kg
Au: ≤0.005 μg/kg
B: ≤0.5 μg/kg
Ba: ≤0.5 μg/kg
Be: ≤0.005 μg/kg
Bi: ≤0.001 μg/kg
Ca: ≤0.5 μg/kg
Cd: ≤0.5 μg/kg
Ce: ≤0.001 μg/kg
Co: ≤0.5 μg/kg
Cr: ≤0.5 μg/kg
Cs: ≤0.001 μg/kg
Cu: ≤0.5 μg/kg
Dy: ≤0.001 μg/kg
Er: ≤0.001 μg/kg
Eu: ≤0.001 μg/kg
Fe: ≤0.5 μg/kg
Ga: ≤0.001 μg/kg
Gd: ≤0.001 μg/kg
Ge: ≤0.005 μg/kg
Hf: ≤0.001 μg/kg
Hg: ≤0.5 μg/kg
Ho: ≤0.001 μg/kg
In: ≤0.001 μg/kg
Ir: ≤0.001 μg/kg
K: ≤0.5 μg/kg
La: ≤0.001 μg/kg
Li: ≤0.5 μg/kg
Lu: ≤0.001 μg/kg
Mg: ≤0.5 μg/kg
Mn: ≤0.5 μg/kg
Mo: ≤0.5 μg/kg
Na: ≤0.5 μg/kg
Nb: ≤0.005 μg/kg
Nd: ≤0.001 μg/kg
Ni: ≤0.005 μg/kg
Os: ≤0.005 μg/kg
Pb: ≤05 μg/kg
Pd: ≤0.001 μg/kg
Pr: ≤0.001 μg/kg
Pt: ≤0.005 μg/kg
Rb: ≤0.001 μg/kg
Re: ≤0.005 μg/kg
Rh: ≤0.001 μg/kg
Ru: ≤0.005 μg/kg
Sb: ≤0.001 μg/kg
Sc: ≤0.005 μg/kg
Se: ≤5 μg/kg
Si: ≤0.5 μg/kg
Sm: ≤0.001 μg/kg
Sn: ≤0.5 μg/kg
Sr: ≤0.5 μg/kg
Ta: ≤0.001 μg/kg
Tb: ≤0.001 μg/kg
Te: ≤0.001 μg/kg
Th: ≤0.005 μg/kg
Ti: ≤0.5 μg/kg
Tl: ≤0.005 μg/kg
Tm: ≤0.001 μg/kg
U: ≤0.001 μg/kg
V: ≤0.5 μg/kg
W: ≤0.005 μg/kg
Y: ≤0.001 μg/kg
Yb: ≤0.001 μg/kg
Zn: ≤0.5 μg/kg
Zr: ≤0.5 μg/kg

SMILES String

O

Anwendung(en)

sample preparation

InChI

1S/H2O/h1H2

InChIKey

XLYOFNOQVPJJNP-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Lagerklassenschlüssel

12 - Non Combustible Liquids

WGK

nwg

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable

Persönliche Schutzausrüstung

Eyeshields, Gloves


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Kunden haben sich ebenfalls angesehen

Slide 1 of 7

1 of 7

Mary A Rodgers et al.
The Journal of experimental medicine, 211(7), 1333-1347 (2014-06-25)
Linear ubiquitination is a newly discovered posttranslational modification that is currently restricted to a small number of known protein substrates. The linear ubiquitination assembly complex (LUBAC), consisting of HOIL-1L, HOIP, and Sharpin, has been reported to activate NF-κB-mediated transcription in
Susu Duan et al.
Nature communications, 5, 5029-5029 (2014-10-10)
Oseltamivir-resistant H1N1 influenza viruses carrying the H275Y neuraminidase mutation predominated worldwide during the 2007-2009 seasons. Although several neuraminidase substitutions were found to be necessary to counteract the adverse effects of H275Y, the order and impact of evolutionary events involved remain
Yasushi Itoh et al.
PLoS pathogens, 10(6), e1004192-e1004192 (2014-06-20)
Highly pathogenic avian influenza (HPAI) viruses of the H5N1 subtype often cause severe pneumonia and multiple organ failure in humans, with reported case fatality rates of more than 60%. To develop a clinical antibody therapy, we generated a human-mouse chimeric
Hervé Marie-Nelly et al.
Nature communications, 5, 5695-5695 (2014-12-18)
Closing gaps in draft genome assemblies can be costly and time-consuming, and published genomes are therefore often left 'unfinished.' Here we show that genome-wide chromosome conformation capture (3C) data can be used to overcome these limitations, and present a computational
Boris Nowka et al.
Applied and environmental microbiology, 81(2), 745-753 (2014-11-16)
Nitrification has an immense impact on nitrogen cycling in natural ecosystems and in wastewater treatment plants. Mathematical models function as tools to capture the complexity of these biological systems, but kinetic parameters especially of nitrite-oxidizing bacteria (NOB) are lacking because

Artikel

Learn more about Bioethanol as a renewable, alternative fuel traditionally produced by the yeast fermentation of sugar.

Separation of Methane; Acetylene; Carbon monoxide; Water; Nitrogen; Carbon dioxide; Ethane; Ethylene

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  3. I need to know the TOC specifications of this product, can i use it for gas chromatography?

    1 answer
    1. This product is not tested for TOC specifications or GC applications. This product is tested for trace metals via ICP-MS.

      Please see the product specification sheet to view the testing performed on this material:
      https://www.sigmaaldrich.com/specification-sheet/SIAL/14211

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.