コンテンツへスキップ
Merck
  • Simplified matrix solid phase dispersion procedure for the determination of parabens and benzophenone-ultraviolet filters in human placental tissue samples.

Simplified matrix solid phase dispersion procedure for the determination of parabens and benzophenone-ultraviolet filters in human placental tissue samples.

Journal of chromatography. A (2014-12-03)
F Vela-Soria, I Rodríguez, O Ballesteros, A Zafra-Gómez, L Ballesteros, R Cela, A Navalón
要旨

In recent decades, the industrial development has resulted in the appearance of a large amount of new chemicals that are able to produce disorders in the human endocrine system. These substances, so-called endocrine disrupting chemicals (EDCs), include many families of compounds, such as parabens and benzophenone-UV filters. Taking into account the demonstrated biological activity of these compounds, it is necessary to develop new analytical procedures to assess the exposure in order to establish, in an accurate way, relationships between EDCs and harmful health effects in population. In the present work, a new method based on a simplified sample treatment by matrix solid phase dispersion (MSPD) followed by ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis, is validated for the determination of four parabens (methyl-, ethyl-, propyl- and butylparaben) and six benzophenone-UV filters (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8 and 4-hydroxybenzophenone) in human placental tissue samples. The extraction parameters were accurately optimized using multivariate optimization strategies. Ethylparaben ring-13C6 and benzophenone-d10 were used as surrogates. The found limits of quantification ranged from 0.2 to 0.4 ng g(-1) and inter-day variability (evaluated as relative standard deviation) ranged from 5.4% to 12.8%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 96% to 104%. The method was satisfactorily applied for the determination of compounds in human placental tissue samples collected at the moment of delivery from 10 randomly selected women.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, suitable for HPLC, ≥99.9%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
酢酸エチル, ACS reagent, ≥99.5%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
酢酸エチル, suitable for HPLC, ≥99.7%
Sigma-Aldrich
メタノール, HPLC Plus, ≥99.9%
Sigma-Aldrich
酢酸エチル, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
アセトニトリル, ACS reagent, ≥99.5%
Sigma-Aldrich
アセトニトリル, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
メタノール, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
メタノール, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
Sigma-Aldrich
酢酸エチル, suitable for HPLC, ≥99.8%
Sigma-Aldrich
メタノール, BioReagent, ≥99.93%
Sigma-Aldrich
酢酸エチル, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.5% (GC)
Sigma-Aldrich
メタノール, Absolute - Acetone free
Sigma-Aldrich
メタノール, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
アセトニトリル, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
酢酸エチル, puriss., meets analytical specification of Ph. Eur., BP, NF, ≥99.5% (GC)
Sigma-Aldrich
4-ヒドロキシ安息香酸エチル, ReagentPlus®, 99%
Sigma-Aldrich
酢酸エチル, anhydrous, 99.8%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
USP
メチルアルコール, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
アセトニトリル, biotech. grade, ≥99.93%
Supelco
メタノール, Pharmaceutical Secondary Standard; Certified Reference Material