If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf
おすすめの製品
使用法
sufficient for 2,500 colorimetric tests
検出方法
colorimetric
関連疾患
cardiovascular diseases; gastrointestinal diseases
保管温度
2-8°C
詳細
アプリケーション
- Phosphatase Assays: liberation of phosphate from peptide, protein, or small molecule substrate.[1][3]
- Lipase Assays: liberation of phosphate from phospholipids
- Nucleoside Triphosphatase Assays: liberation of phosphate from nucleoside triphosphates (ATP, GTP, TTP, CTP etc).
- Quantitation of phosphate in phospholipids, proteins and DNAs, etc.
- Drug Discovery: high-throughput screen for phosphatase inhibitors.
特徴および利点
適合性
原理
シグナルワード
Warning
危険有害性情報
危険有害性の分類
Eye Irrit. 2 - Flam. Liq. 3 - Met. Corr. 1 - Skin Irrit. 2
保管分類コード
3 - Flammable liquids
引火点(°F)
82.4 °F
引火点(℃)
28 °C
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
毒物及び劇物取締法
キットコンポーネントの情報を参照してください
PRTR
キットコンポーネントの情報を参照してください
消防法
キットコンポーネントの情報を参照してください
労働安全衛生法名称等を表示すべき危険物及び有害物
キットコンポーネントの情報を参照してください
労働安全衛生法名称等を通知すべき危険物及び有害物
キットコンポーネントの情報を参照してください
カルタヘナ法
キットコンポーネントの情報を参照してください
Jan Code
キットコンポーネントの情報を参照してください
最新バージョンのいずれかを選択してください:
試験成績書(COA)
この製品を見ている人はこちらもチェック
-
How can I determine the shelf life / expiration / retest date of this product?
1 回答-
役に立ちましたか?
-
-
Is this kit able to detect pyrophosphate too?
1 回答-
This kit is intended for the detection of free orthophosphate and has not been tested for pyrophosphate detection. There are other products available that are specifically for use in pyrophosphate detection. Please see the links below to review each item:
MAK168, Pyrophosphate Assay Kit
https://www.sigmaaldrich.com/product/sigma/mak168
MAK169. High Sensitivity Pyrophosphate Assay Kit
https://www.sigmaaldrich.com/product/sigma/mak169役に立ちましたか?
-
-
Does the product MAK307 contain magnesium?
1 回答-
Magnesium is not included as a component in any of the reagents provided with the kit for product MAK307. If magnesium serves as an essential cofactor for the enzyme, it is recommended to supplement it in the buffer before conducting the phosphate determination assay.
役に立ちましたか?
-
-
What are the reasons behind the suggestion to use lower concentrations than 0.25mM? Are there potential unwanted biochemical reactions between GTP and malachite green/molybdate if GTP concentration exceeds 0.25mM?
1 回答-
The kit operates by releasing free orthophosphate from ATP or GTP, followed by the creation of a green complex involving the orthophosphate, molybdate, and Malachite green. It has been observed that samples containing ATP and GTP at concentrations exceeding 0.25mM result in the measurement of free phosphate levels falling outside the detection range of the kit (0.02 µM and 40 µM phosphate), and hence should be avoided.
役に立ちましたか?
-
-
Why is it necessary to dilute the ATP concentration to <0.25 mM before the assay? Does ATP interfere with the assay?
1 回答-
BioAssay Support recommends reducing the ATP concentration before the assay to minimize background interference resulting from non-enzymatic ATP hydrolysis and to decrease the likelihood of reagent precipitation with unhydrolyzed ATP.
役に立ちましたか?
-
-
our kit expired, when I used to measure extracted polyphosphate degraded by the enzyme, the results were so different compared to the precious ones (when the kit was not expired), this means the result was not reliable after it expired?
1 回答-
Correct, products used beyond the expiration date will likely offer poor results.
役に立ちましたか?
-
-
Does Malachite Green interact with glycerol?
1 回答-
The Malachite Green Phosphate Assay Kit is based on the quantification of the green complex formed between Malachite Green, molybdate, and free orthophosphate. No specific compatibility study has been done with this kit and glycerol. This would need to be tested empirically, in a sample with a known phosphate concentration, with and without glycerol at the desired concentration.
役に立ちましたか?
-
-
Can we test the same MG in shrimp matrix ?
1 回答-
This product is suitable for a variety of sample types. There is no reason to suspect a problem with shrimp matrix. Attention should be given to sample preparation, handling, and dilution. See the link below to review the product datasheet which includes the protocol and troubleshooting tips:
https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/171/212/mak307bul.pdf役に立ちましたか?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
0 回答
アクティブなフィルタ
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)