5.43834

Supelco

Ammonium acetate

for HPLC LiChropur

別名:

Ammonium acetate

ログイン組織・契約価格を表示する


About This Item

実験式(ヒル表記法):
C2H7NO2
CAS番号:
分子量:
77.08
MDL番号:
UNSPSCコード:
12352106
EC Index Number:
211-162-9
NACRES:
NA.21
現在、価格および在庫状況を閲覧できません。

認証

suitable for ASTM® 7968
suitable for ASTM® 7979
suitable for DIN 38407-42
suitable for EPA 1633
suitable for EPA 533
suitable for EPA 537.1
suitable for EPA 8327
suitable for EPA ACB B21-02
suitable for EPA ACB B23-05b
suitable for GB 31604.35-2016
suitable for GB 5009.253-2016
suitable for ISO 21675 2019
suitable for ISO 25101
suitable for ISO/CEN 15968-2010

品質水準

法規制遵守

suitable for FDA C-010.02

フォーム

solid

テクニック

HPLC: suitable

pH

6.7-7.3 (25 °C, 50 g/L in H2O)

mp

114 °C

溶解性

1480 g/L

密度

1.17 g/cm3 at 20 °C

かさ密度

410 kg/m3

アプリケーション

PFAS testing

保管温度

15-25°C

SMILES記法

[NH4]OC(=O)C

InChI

1S/C2H4O2.H3N/c1-2(3)4;/h1H3,(H,3,4);1H3

InChI Key

USFZMSVCRYTOJT-UHFFFAOYSA-N

詳細

Ammonium acetate is commonly used as a buffer in high-performance liquid chromatography (HPLC). It is used as a mobile phase to develop a novel speciation methodology applicable to urine samples using IEC-ICP-MS.[1]

アプリケーション

Ammonium acetate can be used as a:
  • Mobile phase in the derivatization reaction to enhance the detection and separation of glyphosate and aminomethylphosphonic acid (AMPA) using reversed-phase liquid chromatography (RPLC).[2]
  • Buffer component in the mobile phase of the Hydrophilic Interaction Liquid Chromatography (HILIC) method for the separation and determination of polar lipid classes.[3]

法的情報

ASTM is a registered trademark of American Society for Testing and Materials
LiChropur is a trademark of Merck KGaA, Darmstadt, Germany

関連製品

製品番号
詳細
価格

保管分類コード

11 - Combustible Solids

WGK

WGK 1

引火点(°F)

Not applicable

引火点(℃)

Not applicable


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

この製品を見ている人はこちらもチェック

Ammonium acetate as a novel buffer for highly selective robust urinary HPLC-ICP-MS arsenic speciation methodology
Rodriguez PF, et al.
Talanta, 221, 121494-121494 (2021)
Hydrophilic interaction liquid chromatography coupled with tandem mass spectrometry method for quantification of five phospholipid classes in various matrices
Mazzella N, et al.
MethodsX, 10, 102026-102026 (2023)
Evaluation and optimization of the derivatization reaction conditions of glyphosate and aminomethylphosphonic acid with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate using reversed-phase liquid chromatography
Fontas, C et al.
Journal of Separation Science, 43(20), 3931-3939 (2020)

関連コンテンツ

FAS、すなわち「永遠の化学物質」は環境中に残留し続け、ヒトの健康にリスクをもたらします。PFAS分析に携わる研究者、規制当局、PFAS定量用のメルクの環境モニタリングツールをご覧ください。

FAS, or 'forever chemicals,' persist in the environment and pose risks to human health. Discover our environmental monitoring tools for PFAS quantification, aiding researchers, regulators, and labs in testing for PFAS.

質問

1–2/2 質問  
  1. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 回答
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      役に立ちましたか?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 回答
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      役に立ちましたか?

レビュー

評価値なし

アクティブなフィルタ

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)