Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Wichtige Dokumente
442785
Squalen
analytical standard
Synonym(e):
2,6,10,15,19,23-Hexamethyl-2,6,10,14,18,22-tetracosahexaen
About This Item
Empfohlene Produkte
Qualität
analytical standard
Qualitätsniveau
Analysenzertifikat (CofA)
current certificate can be downloaded
Verpackung
ampule of 1000 mg
Methode(n)
HPLC: suitable
gas chromatography (GC): suitable
Brechungsindex
n20/D 1.494 (lit.)
bp
285 °C/25 mmHg (lit.)
mp (Schmelzpunkt)
−75 °C (lit.)
Dichte
0.858 g/mL at 25 °C (lit.)
Anwendung(en)
environmental
food and beverages
Format
neat
Lagertemp.
2-30°C
SMILES String
CC(C)=CCCC(C)=CCCC(C)=CCC\C=C(/C)CCC=C(C)CCC=C(C)C
InChI
1S/C30H50/c1-25(2)15-11-19-29(7)23-13-21-27(5)17-9-10-18-28(6)22-14-24-30(8)20-12-16-26(3)4/h15-18,23-24H,9-14,19-22H2,1-8H3/b27-17+,28-18+,29-23+,30-24+
InChIKey
YYGNTYWPHWGJRM-AAJYLUCBSA-N
Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich
Allgemeine Beschreibung
Anwendung
- Analysis of 119 vegetable oil samples from 7 different varieties to detect and determine squalene and four sterols using a developed and validated non-destructive method based on proton nuclear magnetic resonance (1H NMR) spectroscopy combined with partial least squares (PLS) method
- Determination of squalene in different oil samples by gas chromatography coupled to flame ionization detection (GC-FID) following base-catalyzed transmethylation of the oil base
- Ultra-high performance liquid chromatography-photodiode array detection (UHPLC-PDA) based quantification of squalene, following its single-step solid phase extraction (SPE) from 33 samples of extra virgin olive oil collected from different countries
- Measurement of squalene content of 16 commercial shark liver oil samples using a gas chromatography-mass spectrometry-based method, in addition to IR and Raman spectroscopy combined with the PLS method
- Multi-residue determination of 14 naturally occurring compounds— squalene, tocopherols, and phytosterols, following their solid phase extraction (SPE) from 15 vegetable oil samples by GC-MS
Sonstige Hinweise
Signalwort
Danger
H-Sätze
P-Sätze
Gefahreneinstufungen
Asp. Tox. 1
Lagerklassenschlüssel
10 - Combustible liquids
WGK
WGK 2
Flammpunkt (°F)
Not applicable
Flammpunkt (°C)
Not applicable
Persönliche Schutzausrüstung
Eyeshields, Gloves
Hier finden Sie alle aktuellen Versionen:
Besitzen Sie dieses Produkt bereits?
In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.
Kunden haben sich ebenfalls angesehen
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Helpful?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdfHelpful?
-
Active Filters
Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..
Setzen Sie sich mit dem technischen Dienst in Verbindung.