Direkt zum Inhalt
Merck

442747-U

Supelco

Perfluortributylamin (PFTBA)

analytical standard

Synonym(e):

Heptacosafluortributylamin, Fluorinert FC-43, PFTBA, Perfluortributylamin, Tris(nonafluorbutyl)amin

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
N(CF2CF2CF2CF3)3
CAS-Nummer:
Molekulargewicht:
671.09
Beilstein:
1813883
EG-Nummer:
MDL-Nummer:
UNSPSC-Code:
77101502
PubChem Substanz-ID:
NACRES:
NA.24
Preise und Verfügbarkeit sind derzeit nicht verfügbar.

Qualität

analytical standard

Qualitätsniveau

Agentur

EPA 625,8240

Dampfdichte

23.3 (vs air)

Dampfdruck

1.3 mmHg ( 25 °C)

Analysenzertifikat (CofA)

current certificate can be downloaded

Leistungsmerkmale

standard type tuning solution

Verpackung

ampule of 1000 mg

Methode(n)

HPLC: suitable
gas chromatography (GC): suitable

bp

178 °C (lit.)

Dichte

1.883 g/mL at 25 °C (lit.)

Anwendung(en)

environmental

Format

neat

Lagertemp.

2-30°C

SMILES String

FC(F)(F)C(F)(F)C(F)(F)C(F)(F)N(C(F)(F)C(F)(F)C(F)(F)C(F)(F)F)C(F)(F)C(F)(F)C(F)(F)C(F)(F)F

InChI

1S/C12F27N/c13-1(14,7(25,26)27)4(19,20)10(34,35)40(11(36,37)5(21,22)2(15,16)8(28,29)30)12(38,39)6(23,24)3(17,18)9(31,32)33

InChIKey

RVZRBWKZFJCCIB-UHFFFAOYSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Verwandte Kategorien

Allgemeine Beschreibung

Perfluorotributylamine (PFTBA) is a neat reference standard, which may be used in environmental analysis.

Anwendung

Perfluorotributylamine (PFTBA) is commonly used for the calibration of the mass axes of mass spectrometers, basically in those systems, which use electron ionization (EI).[1] PFTBA may be used as a calibration standard for the gas chromatography-mass spectrometric determination of tramadol in human plasma samples[2] and phthalate esters in water samples.[3]
Refer to the product′s Certificate of Analysis for more information on a suitable instrument technique. Contact Technical Service for further support.

Lagerklassenschlüssel

10 - Combustible liquids

WGK

WGK 2

Persönliche Schutzausrüstung

Eyeshields, Gloves, type ABEK (EN14387) respirator filter


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Validation of a GC/MS method for the determination of tramadol in human plasma after intravenous bolus
Gambaro V, et al.
Il Farmaco (Societa Chimica Italiana : 1989), 58(8), 947-950 (2003)
Comparison of different fibers for the solid-phase microextraction of phthalate esters from water
Penalver A, et al.
Journal of Chromatography A, 922(1-2), 377-384 (2001)
Pharmaceutical Analysis E-Book: A Textbook for Pharmacy Students and Pharmaceutical Chemists, 4 (2015)
X Zhu et al.
Hunan yi ke da xue xue bao = Hunan yike daxue xuebao = Bulletin of Hunan Medical University, 24(3), 253-255 (2002-05-23)
To evaluate the clinical application value of perfluorotributylamine liquid (PFTL) made in China in the complicated retinal detachment. PFTL was injected into eyeball after vitreoretinal surgery, it could open funnel of retinal detachment, push subretinal fluid out from peripheral hole
V M Knepp et al.
Pharmaceutical research, 15(7), 1090-1095 (1998-08-04)
To identify a suitable nonaqueous, parenterally acceptable suspending vehicle whereby a therapeutic protein is delivered as a stable flowable powder, making it amenable to delivery from sustained delivery systems maintained at body temperature. Formulations of plasma derived Factor IX (pdFIX)

Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/449/386/product-dating-information-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.