Biomonitoring occupational sevoflurane exposure at low levels by urinary sevoflurane and hexafluoroisopropanol.

Toxicology letters (2014-12-03)
Maria Luisa Scapellato, Mariella Carrieri, Isabella Maccà, Fabiola Salamon, Andrea Trevisan, Maurizio Manno, Giovanni Battista Bartolucci
ABSTRAKT

This study aimed to correlate environmental sevoflurane levels with urinary concentrations of sevoflurane (Sev-U) or its metabolite hexafluoroisopropanol (HFIP) in order to assess and discuss the main issues relating to which biomarker of sevoflurane exposure is best, and possibly suggest the corresponding biological equivalent exposure limit values. Individual sevoflurane exposure was measured in 100 healthcare operators at five hospitals in north-east Italy using the passive air sampling device Radiello(®), and assaying Sev-U and HFIP concentrations in their urine collected at the end of the operating room session. All analyses were performed by gas chromatography-mass spectrometry. Environmental sevoflurane levels in the operating rooms were also monitored continuously using an infrared photoacoustic analyzer. Our results showed very low individual sevoflurane exposure levels, generally below 0.5 ppm (mean 0.116 ppm; range 0.007-0.940 ppm). Sev-U and HFIP concentrations were in the range of 0.1-17.28 μg/L and 5-550 μg/L, respectively. Both biomarkers showed a statistically significant correlation with the environmental exposure levels (Sev-U, r=0.49; HFIP, r=0.52), albeit showing fairly scattered values. Sev-U values seem to be influenced by peaks of exposure, especially at the end of the operating-room session, whereas HFIP levels by exposure on the previous day, the data being consistent with the biomarkers' very different half-lives (2.8 and 19 h, respectively). According to our results, both Sev-U and HFIP are appropriate biomarkers for assessing sevoflurane exposure at low levels, although with some differences in times/patterns of exposure. More work is needed to identify the best biomarker of sevoflurane exposure and the corresponding biological equivalent exposure limit values.

MATERIAŁY
Numer produktu
Marka
Opis produktu

Supelco
radiello BTEX Calibration Kit (Thermal Desorption)
radiello Clips, suspending Radiello triangular support plate, pk of 20
radiello Filtration Kit, pk of 20
radiello On-Field Thermometer, Includes one standard Radiello vertical adapter (RAD122) for each thermometer, configured for standard use, pk of 3
radiello BTEX/VOC Starter Kit, CS2 Desorption
radiello Diffusive Bodies, white, configured for general use, pk of 20
radiello On-Field Thermometer, Reader, pk of 1
radiello Diffusive Bodies, blue, configured for sampling light sensitive compounds, pk of 20
Supelco
radiello Aldehyde Calibration Standard, 50 μg/mL each component in acetonitrile, pkg of 10 mL
Supelco
radiello Methylene Blue Calibration Standard for H2S (Hydrogen Sulfide), pkg of 100 mL
radiello Empty Storage Tubes, glass (with stopper), volume 2.8 mL, pk of 100
radiello Diffusive Bodies, yellow, configured for reduced sampling rates, pk of 20
radiello Diffusive Bodies, permeative, configured for anaesthetic gases and vapors, pk of 20
radiello 1,3-Butadiene Starter Kit, Thermal Desorption, pkg of 1 kit (2 RAD141 adsorbing cartridges and barcode labels, 1 RAD1202 yellow diffusive body, 1 RAD121 triangular support plate, 1 instruction sheet)
radiello BTEX/VOC Starter Kit, Thermal Desorption
Supelco
radiello BTEX Calibration Kit (CS2 Desorption)
Supelco
1,1,1,3,3,3-Hexafluoro-2-propanol, for GC derivatization, LiChropur, ≥99.8%
3778 Zestaw startowy siarkowodoru
Sigma-Aldrich
1,1,1,3,3,3-Hexafluoro-2-propanol, ≥99%
radiello Empty Storage Tubes, polypropylene (with stopper), volume 12 mL, pk of 100
radiello Cartridge Adsorbents, for sampling Anaesthetic Gases/Vapors, matrix SS net with mix of mol sieve and activated charcoal (30-50 mesh), pk of 20
radiello Cartridge Adsorbents, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
radiello Triangular Support Plate, pk of 20
radiello Vertical Adapter, threaded for standard use, pk of 20
radiello Cartridge Adsorbents, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
radiello Outdoor Shelter, pk of 10
radiello Replacement Mounting Strips, for use with Radiello Outdoor Shelter, pk of 100
radiello Cartridge Adsorbents, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
Sigma-Aldrich
Creatinine, anhydrous, ≥98%
radiello Barcode Labels, pk of 198