コンテンツへスキップ
Merck
  • A HPLC-SRM-MS based method for the detection and quantification of methotrexate in urine at doses used in clinical practice for patients with rheumatological disease: a potential measure of adherence.

A HPLC-SRM-MS based method for the detection and quantification of methotrexate in urine at doses used in clinical practice for patients with rheumatological disease: a potential measure of adherence.

The Analyst (2015-02-12)
J Bluett, I Riba-Garcia, K Hollywood, S M M Verstappen, A Barton, R D Unwin
要旨

Rheumatoid arthritis (RA) is a common autoimmune disease that causes significant disability and reduced life expectancy. The folate antagonist methotrexate (MTX) is first-line therapy for RA when used weekly at low doses (5-25 mg). However, the true rate of adherence to MTX is uncertain. This is in part due to the different methods of measurement of adherence employed with no biochemical test currently available to determine adherence to low dose MTX. Common methods of MTX measurement include immunoassays in patients with high dose therapy, but these assays cross-react with MTX metabolites and lack the sensitivity required to measure adherence to low dose MTX. HPLC-SRM-MS (selected reaction monitoring-mass spectrometry) has several theoretical advantages over immunoassays with improved specificity, minimal cross-reaction and higher sensitivity. The aim of this study was to develop an assay to measure MTX and its major metabolite 7-OH-MTX in urine as a tool to monitor adherence to low dose MTX in clinic. As a proof of concept, urine samples from 4 participants with RA were measured after directly observed therapy. The assay showed improved sensitivity compared to that reported by immunoassays, with low carryover and high within-run precision. In participant samples, MTX was measurable in the urine for up to 105 hours after administration and 7-OH-MTX was detectable up to 98 hours after administration, suggesting that this assay is suitable for the measurement of adherence to therapy. The assay requires minimal sample preparation and can be adopted by other laboratories with minimal study set up.

材料
製品番号
ブランド
製品内容

Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, suitable for HPLC, ≥99.9%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
ギ酸, reagent grade, ≥95%
Sigma-Aldrich
メタノール, HPLC Plus, ≥99.9%
Sigma-Aldrich
ギ酸, ACS reagent, ≥96%
Sigma-Aldrich
ギ酸, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
アセトニトリル, ACS reagent, ≥99.5%
Sigma-Aldrich
アセトニトリル, for HPLC, for UV, ≥99.9% (GC)
Sigma-Aldrich
アセトニトリル, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
メタノール, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
メタノール, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
アセトニトリル, anhydrous, 99.8%
Sigma-Aldrich
ギ酸, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
メタノール, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
ギ酸, ACS reagent, ≥88%
Sigma-Aldrich
メタノール, BioReagent, ≥99.93%
Sigma-Aldrich
メタノール, Absolute - Acetone free
Sigma-Aldrich
メタノール, ACS spectrophotometric grade, ≥99.9%
SAFC
メトトレキサート
Sigma-Aldrich
アセトニトリル, suitable for HPLC-GC, ≥99.8% (GC)
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%
Sigma-Aldrich
メタノール, JIS special grade, ≥99.8%
Sigma-Aldrich
メタノール, anhydrous, 99.8%
USP
メチルアルコール, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
アセトニトリル, biotech. grade, ≥99.93%
Sigma-Aldrich
重水素, 99.8 atom % D
Sigma-Aldrich
メタノール, SAJ first grade, ≥99.5%
Sigma-Aldrich
メタノール, ACS reagent, ≥99.8%