Passa al contenuto
Merck
  • Determination of irinotecan and its metabolite SN-38 in rabbit plasma and tumors using a validated method of tandem mass spectrometry coupled with liquid chromatography.

Determination of irinotecan and its metabolite SN-38 in rabbit plasma and tumors using a validated method of tandem mass spectrometry coupled with liquid chromatography.

Journal of chromatography. B, Analytical technologies in the biomedical and life sciences (2014-06-14)
Dae J Park, Jun H Won, A R Cho, Hye J Yun, Jeong H Heo, Tae H Hwhang, Dae H Lee, Woo M Kim
ABSTRACT

New tandem mass spectrometric method coupled with liquid chromatography (LC-MS/MS) has been developed to determine the total concentration of camptothecin derivatives (irinotecan and SN-38) regardless of inter-conversion phenomenon between carboxylate and lactone forms. At first, all sample solutions were acidified for 1h in order to completely convert CPT derivatives into their lactone forms and then CPT derivatives were extracted with organic solution containing diethyl ether and ethyl acetate (2:1, v/v) just after alkalization in the range pH 8.0-8.5 in acid-treated solutions. Analytes were separated on a reverse phase C18 column (150×2.1mm) and eluted isocratically with a mobile phase which consisted of acetonitrile-methanol-buffer (0.1% formic acid, 5mM ammonium formate) (3:4:3, v/v). CPT derivatives were monitored by tandem mass spectrometry in electrospay-positive ionization and multiple reaction mode programmed to the following transitions (m/z): '587.6→167.2' of CPT-11, '393.6→349.3' of SN-38 and '349.4→ 305.2' of CPT. The method was validated to have the proper linearity (r(2)>0.99) over the range of 5-1000ng/ml of CPT-11 and 1-250ng/ml of SN-38 with good accuracy (89.8-114.3%) and precision (less than 10%). In all stability tests, concentration of CPT-11 and SN-38 had been left in the acceptable range of 88.8-110.7% when sample solutions were acidified before determination of CPT derivatives. Newly developed LC-MS/MS method was suitable for the determination of CPT derivatives of both rabbit plasma and tumor tissues in the pharmacokinetic study.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanolo, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Sigma-Aldrich
Etilacetato, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Etilacetato, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Dietiletere, anhydrous, ACS reagent, ≥99.0%, contains BHT as inhibitor
Sigma-Aldrich
Acido formico, reagent grade, ≥95%
Sigma-Aldrich
Metanolo, HPLC Plus, ≥99.9%
Sigma-Aldrich
Dietiletere, suitable for HPLC, ≥99.9%, inhibitor-free
Sigma-Aldrich
Etilacetato, HPLC Plus, for HPLC, GC, and residue analysis, 99.9%
Sigma-Aldrich
Acido formico, ACS reagent, ≥96%
Sigma-Aldrich
Dietiletere, ACS reagent, anhydrous, ≥99.0%, contains BHT as inhibitor
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Formato di ammonio, reagent grade, 97%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Metanolo, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Metanolo, Laboratory Reagent, ≥99.6%
Sigma-Aldrich
Formato di ammonio, ≥99.995% trace metals basis
Sigma-Aldrich
Acido formico, ACS reagent, ≥88%
Sigma-Aldrich
Etilacetato, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Metanolo, BioReagent, ≥99.93%
Sigma-Aldrich
Metanolo, Absolute - Acetone free
Sigma-Aldrich
Metanolo, ACS spectrophotometric grade, ≥99.9%
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Metanolo, ACS reagent, ≥99.8%
Supelco
Formato di ammonio, eluent additive for LC-MS, LiChropur, ≥99.0%
USP
Metanolo, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Dietiletere