Összes fotó(1)
Fontos dokumentumok
RAB0736
Human SDC1 / Syndecan-1 ELISA Kit
Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez
Összes fotó(1)
About This Item
Javasolt termékek
faj reaktivitás
human
kiszerelés
kit of 96 wells (12 strips x 8 wells)
technika/technikák
ELISA: suitable
bemenet
sample type cell culture supernatant(s)
sample type serum
sample type plasma
assay range
inter-assay cv: <12%
intra-assay cv: <10%
sensitivity: 14 pg/mL
standard curve range: 16.38-4000 pg/mL
észlelési módszer
colorimetric
kiszállítva
wet ice
tárolási hőmérséklet
−20°C
Géninformáció
human ... SDC1(6382)
Általános leírás
The antibody pair provided in this kit recognize human Syndecan-1/CD138.
Alkalmazás
For research use only. Not for use in diagnostic procedures.
Please refer to the attached General ELISA KIT Procedure (sandwich, competitive & Indirect ELISA)
Please refer to the attached General ELISA KIT Procedure (sandwich, competitive & Indirect ELISA)
Egyéb megjegyzések
A sample Certificate of Analysis is available for this product.
Please type the word sample in the text box provided for lot number.
Please type the word sample in the text box provided for lot number.
Figyelmeztetés
Warning
Figyelmeztető mondatok
Óvintézkedésre vonatkozó mondatok
Veszélyességi osztályok
Met. Corr. 1
Tárolási osztály kódja
8A - Combustible corrosive hazardous materials
Lobbanási pont (F)
Not applicable
Lobbanási pont (C)
Not applicable
Válasszon a legfrissebb verziók közül:
Már rendelkezik ezzel a termékkel?
Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.
Biomarkers : biochemical indicators of exposure, response, and susceptibility to chemicals, 25(6), 425-435 (2020-07-01)
Despite wide interest in glycocalyx biomarkers, their values in healthy individuals, patients after abdominal surgery, and septic patients have been poorly understood. We searched MEDLINE, CENTRAL and EMBASE for papers measured glycocalyx biomarkers in healthy individuals, patients after abdominal surgery
American journal of surgery, 217(6), 1076-1082 (2019-01-13)
Hyperglycemia promotes vascular inflammation; however its effect on endothelial dysfunction in sepsis is unknown. Microfluidic devices (MFD) may closely mimic the in vivo endothelial cell microenvironment. We hypothesized that stress glucose concentrations would increase sepsis related endothelial injury/activation. Human umbilical vein
Frontiers in cell and developmental biology, 8, 599-599 (2020-08-08)
Mammographic density (MD) is a strong and independent factor for breast cancer (BC) risk and is increasingly associated with BC progression. We have previously shown in mice that high MD, which is characterized by the preponderance of a fibrous stroma
Blood coagulation & fibrinolysis : an international journal in haemostasis and thrombosis, 30(5), 181-187 (2019-06-04)
: Coagulopathy has a high incidence in critically ill patients and is often caused by disseminated intravascular coagulation (DIC). Although the clinical picture of DIC ranges from a prothrombotic state to severe consumption coagulopathy with an increased bleeding tendency, there
Cancers, 11(9) (2019-08-25)
Epithelial ovarian cancer (EOC) is the fifth most common cancer affecting the female population. At present, different targeted treatment approaches may improve currently employed therapies leading either to the delay of tumor recurrence or to disease stabilization. In this study
Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.
Lépjen kapcsolatba a szaktanácsadással