Összes fotó(1)
Fontos dokumentumok
568899
3-Mercaptophenol
96%
Szinonimák:
3-Hydroxythiophenol
Bejelentkezésa Szervezeti és Szerződéses árazás megtekintéséhez
Összes fotó(1)
About This Item
Javasolt termékek
Minőségi szint
Teszt
96%
törésmutató
n20/D >1.6290 (lit.)
bp
242-243 °C (lit.)
mp
16-17 °C (lit.)
sűrűség
1.237 g/mL at 25 °C (lit.)
SMILES string
Oc1cccc(S)c1
InChI
1S/C6H6OS/c7-5-2-1-3-6(8)4-5/h1-4,7-8H
Nemzetközi kémiai azonosító kulcs
DOFIAZGYBIBEGI-UHFFFAOYSA-N
Általános leírás
3-mercaptophenol coated cantilevers can be used as formaldehyde sensors since it is highly selective towards formaldehyde and can show highest downward deflection on coming in contact with it.
Alkalmazás
3-mercaptophenol may be used in the synthesis of the following:
- 4-(3-hydroxyphenylthio)naphthalene-1,2-dione, which shows fluorosence emission
- [C6H4-1-(SPPh2)-3-(OPPh2)], a non-symmetric ligand which can combine with PdCl2 to form a pincer complex
Figyelmeztetés
Danger
Figyelmeztető mondatok
Óvintézkedésre vonatkozó mondatok
Veszélyességi osztályok
Eye Dam. 1 - Skin Sens. 1
Tárolási osztály kódja
10 - Combustible liquids
WGK
WGK 3
Lobbanási pont (F)
Not applicable
Lobbanási pont (C)
Not applicable
Egyéni védőeszköz
Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter
Válasszon a legfrissebb verziók közül:
Már rendelkezik ezzel a termékkel?
Az Ön által nemrégiben megvásárolt termékekre vonatkozó dokumentumokat a Dokumentumtárban találja.
"Microfabricated formaldehyde gas sensors"
Sensors, 9(11), 9196-9215 (2009)
"Fluorescence properties, aluminium ion selective emission changes and self-assemblies of positional isomers of 4-(hydroxyphenylthio) naphthalene-1, 2-diones"
Dyes and Pigments, 110, 56- 66 (2014)
"Synthesis of a novel non-symmetric Pd (II) phosphinito?thiophosphinito PSCOP pincer compound"
"Synthesis of a novel non-symmetric Pd (II) phosphinito?thiophosphinito PSCOP pincer compound"
"Synthesis of a novel non-symmetric Pd (II) phosphinito?thiophosphinito PSCOP pincer compound"
Inorgorganica Chimica Acta, 363(6), 1306-1310 (2010)
"Detection of formaldehyde vapor using mercaptophenol-coated piezoresistive cantilevers"
Sensors and Actuators B, Chemical, 126(2), 522-526 (2007)
Advanced science (Weinheim, Baden-Wurttemberg, Germany), 7(10), 1903730-1903730 (2020-05-23)
Reliable monitoring of metabolites in biofluids is critical for diagnosis, treatment, and long-term management of various diseases. Although widely used, existing enzymatic metabolite assays face challenges in clinical practice primarily due to the susceptibility of enzyme activity to external conditions
Tudóscsoportunk valamennyi kutatási területen rendelkezik tapasztalattal, beleértve az élettudományt, az anyagtudományt, a kémiai szintézist, a kromatográfiát, az analitikát és még sok más területet.
Lépjen kapcsolatba a szaktanácsadással