Passa al contenuto
Merck

Method development for impurity profiling in SFC: The selection of a dissimilar set of stationary phases.

Journal of pharmaceutical and biomedical analysis (2015-01-30)
Charlene Galea, Debby Mangelings, Yvan Vander Heyden
ABSTRACT

Supercritical fluid chromatography (SFC) is drawing considerable interest as separation technique in the pharmaceutical industry. The technique is already well established in chiral separations both analytically and on a preparative scale. The use of SFC as a technique for drug impurity profiling is examined here. To define starting conditions in method development for drug impurity profiling, a set of dissimilar stationary phases is screened in parallel. The possibility to select a set of dissimilar columns using the retention factors (k-values) for a set of 64 drugs measured on 27 columns in SFC was examined. Experiments were carried out at a back-pressure of 150 bar and 25 °C with a mobile phase consisting of CO2 and methanol with 0.1% isopropylamine (5-40% over 10 min) at a flow rate of 3 mL/min. These k-values were then used to calculate correlation coefficients on the one hand and to perform a principal component analysis on the other. The Kennard and Stone algorithm, besides dendrograms and correlation-coefficient colour maps were used to select a set of 6 dissimilar stationary phases. The stationary phase characterization results from this study were compared to those from previous studies found in the literature. Retention mechanisms for compounds possessing different properties were also evaluated. The dissimilarity of the selected subset of 6 stationary phases was validated using mixtures of compounds with similar properties and structures, as one can expect in a drug impurity profile.

MATERIALI
N° Catalogo
Marchio
Descrizione del prodotto

Sigma-Aldrich
Dopamine hydrochloride
Sigma-Aldrich
Acido cloridrico, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Acido cloridrico, 36.5-38.0%, BioReagent, for molecular biology
Sigma-Aldrich
Fenolo, BioReagent, Equilibrated with 10 mM Tris HCl, pH 8.0, 1 mM EDTA, for molecular biology
Supelco
Acido cloridrico, volumetric, 0.1 M HCl (0.1N), endotoxin free
Sigma-Aldrich
2-Propanolo, ≥99.7%, FCC, FG
Sigma-Aldrich
Acetylsalicylic acid, ≥99.0%
Sigma-Aldrich
Isopropylamine, ≥99.5%
Sigma-Aldrich
2-Propanolo, for molecular biology, BioReagent, ≥99.5%
Sigma-Aldrich
Metanolo, anhydrous, 99.8%
Sigma-Aldrich
2-Propanolo, BioUltra, for molecular biology, ≥99.5% (GC)
Sigma-Aldrich
Benzylamine, ReagentPlus®, 99%
Sigma-Aldrich
2-Propanolo, anhydrous, 99.5%
Sigma-Aldrich
Fenolo, BioReagent, Saturated with 0.01 M citrate buffer, pH 4.3 ± 0.2, for molecular biology
Sigma-Aldrich
2-Propanolo, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Fenolo, ≥99%
Sigma-Aldrich
Hydrogen chloride, ReagentPlus®, ≥99%
Sigma-Aldrich
Diclofenac
Sigma-Aldrich
Aspirin, meets USP testing specifications
Sigma-Aldrich
1,1-Dimethylbiguanide hydrochloride, 97%
Sigma-Aldrich
Salicylic acid, ACS reagent, ≥99.0%
Sigma-Aldrich
Acido cloridrico, ~6 M in H2O, for amino acid analysis
Sigma-Aldrich
Carbamazepine, powder
Sigma-Aldrich
Fenolo, puriss. p.a., ACS reagent, reag. Ph. Eur., 99.0-100.5%
Sigma-Aldrich
Procaine hydrochloride, ≥97%
Sigma-Aldrich
Cloruro di idrogeno, 3 M in cyclopentyl methyl ether (CPME)
Sigma-Aldrich
Prazosin hydrochloride, ≥99.0% (HPLC)
Sigma-Aldrich
Fenolo, natural, 97%, FG
Sigma-Aldrich
Diphenhydramine hydrochloride, ≥98% (HPLC)
Sigma-Aldrich
Acido cloridrico, 32 wt. % in H2O, FCC