Direkt zum Inhalt
Merck
  • Novel reverse-phase ion pair-high performance liquid chromatography separation of heparin, heparan sulfate and low molecular weight-heparins disaccharides and oligosaccharides.

Novel reverse-phase ion pair-high performance liquid chromatography separation of heparin, heparan sulfate and low molecular weight-heparins disaccharides and oligosaccharides.

Journal of chromatography. A (2013-03-05)
Fabio Galeotti, Nicola Volpi
ZUSAMMENFASSUNG

In this study, by using tetrabutylammonium bisulfate as ion-pairing reagent, we were able to separate all the main heparin/heparan sulfate disaccharides generated by the action of heparinases along with the main Hep tetrasaccharide possessing a 3-O-sulfate group on the sulfoglucosamine unit and resistant to enzymatic action. Moreover, this novel HPLC method was able to separate and quantify uncommon disaccharides/oligosaccharides present in low molecular weight-heparins produced by chemical treatment with nitrous acid, dalteparin, or benzylation followed by alkaline hydrolysis, enoxaparin. Additionally, this procedure yields a sensitivity ∼4-times higher compared to conventional strong-anion exchange-HPLC separation. This was obtained by a common UV detector at 232 nm avoiding the use of complex procedures capable of increasing sensitivity by post-column derivatization. Finally, it is worth mentioning that disaccharide/oligosaccharide composition by HPLC and UV detection is a common analytical approach in quality control laboratories to evaluate heparins and low molecular weight-heparins structure and quality during their extraction and production. This simple HPLC approach offers high resolution and sensitivity for the rapid differentiation of pharmaceutical native heparins and derivatives and for the compositional analysis of small amounts of samples derived from biological sources at a glycosaminoglycans level of a few hundred nanogram.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Tetrabutylammoniumphosphat monobasisch -Lösung, 1.0 M in H2O
Sigma-Aldrich
Tetrabutylammoniumfluorid -Lösung, 1.0 M in THF
Sigma-Aldrich
Tetrabutylammoniumhydroxid -Lösung, 40 wt. % in H2O
Sigma-Aldrich
Tetrabutylammoniumchlorid, ≥97.0% (NT)
Sigma-Aldrich
Tetrabutylammoniumhydroxid -Lösung, 1.0 M in methanol
Sigma-Aldrich
Tetrabutylammoniumiodid, reagent grade, 98%
Supelco
Tetrabutylammoniumhydroxid -Lösung, ~40% in water, suitable for ion chromatography
Sigma-Aldrich
Tetrabutylammoniumhydrogensulfat, 97%
Sigma-Aldrich
Tetrabutylammoniumbromid, ACS reagent, ≥98.0%
Sigma-Aldrich
Tetrabutylammoniumphosphat monobasisch, puriss., 99% (T)
Sigma-Aldrich
Tetrabutylammoniumperchlorat, ≥95.0% (T)
Sigma-Aldrich
Tetrabutylammoniumbisulfat, puriss., ≥99.0% (T)
Sigma-Aldrich
Tetrabutylammoniumcyanid, 95%
Sigma-Aldrich
Tetrabutylammoniumbromid, ReagentPlus®, ≥99.0%
Supelco
Tetrabutylammoniumbisulfat, suitable for ion pair chromatography, LiChropur, ≥99.0%
Sigma-Aldrich
Tetrabutylammoniumnitrat, 97%
Sigma-Aldrich
Tetrabutylammoniumiodid, ≥99.0% (AT)
Sigma-Aldrich
Tetrabutylammonium-Azid
Sigma-Aldrich
Tetrabutylammoniumfluorid -Lösung, 75 wt. % in H2O
Supelco
Tetrabutylammoniumperchlorat, for electrochemical analysis, ≥99.0%
Sigma-Aldrich
Tetrabutylammoniumhydroxid -Lösung, technical, ~40% in H2O (~1.5 M)
Supelco
Tetrabutylammoniumbromid, suitable for ion pair chromatography, LiChropur, ≥99.0%
Sigma-Aldrich
Tetrabutylammoniumhydroxid -Lösung, 53.5-56.5% in H2O
Sigma-Aldrich
Tetrabutylammoniumbromid, 50 wt. % in H2O
Sigma-Aldrich
Tetrabutylammoniumcyanid, technical, ≥80%
Sigma-Aldrich
Tetrabutylammonium-bisulfat -Lösung, ~55% in H2O
Supelco
Tetrabutylammoniumchlorid, suitable for ion pair chromatography, LiChropur, ≥99.0%
Supelco
Tetrabutylammonium-bisulfat -Lösung, suitable for ion pair chromatography, LiChropur, concentrate, ampule
Supelco
Tetrabutylammoniumiodid, suitable for ion pair chromatography, LiChropur, ≥99.0%