Direkt zum Inhalt
Merck
  • Levels and sources of volatile organic compounds including carbonyls in indoor air of homes of Puertollano, the most industrialized city in central Iberian Peninsula. Estimation of health risk.

Levels and sources of volatile organic compounds including carbonyls in indoor air of homes of Puertollano, the most industrialized city in central Iberian Peninsula. Estimation of health risk.

International journal of hygiene and environmental health (2015-05-31)
Florentina Villanueva, Araceli Tapia, Mariano Amo-Salas, Alberto Notario, Beatriz Cabañas, Ernesto Martínez
ZUSAMMENFASSUNG

Twenty nine organic air pollutants including carbonyl compounds, alkanes, aromatic hydrocarbons and terpenes were measured in the indoor environment of different houses together with the corresponding outdoor measurements in Puertollano, the most industrialized city in central Iberian Peninsula. VOCs were sampled during 8 weeks using Radiello(®) passive samplers, and a questionnaire on potential VOCs sources was filled out by the occupants. The results show that formaldehyde and hexanal was the most abundant VOCs measured in indoor air, with a median concentration of 55.5 and 46.4μgm(-3), respectively followed by butanal (29.1μgm(-3)), acetone (28.4μgm(-3)) and acetaldehyde (21.4μgm(-3)). After carbonyls, n-dodecane (13.1μgm(-3)) and terpenes (α-pinene, 13.4μgm(-3) and limonene, 13.4μgm(-3)) were the compounds with higher median concentrations. The indoor/outdoor (I/O) ratios demonstrated that sources in the indoor environment are prevailing for most of the investigated VOCs especially for limonene, α-pinene, hexanal, formaldehyde, pentanal, acetaldehyde, o-xylene, n-dodecane and acetone with I/O ratio >6. Multiple linear regressions were applied to investigate the indoor VOC determinants and Spearman correlation coefficients were used to establish common sources between VOCs. Finally, the lifetime cancer risk associated to formaldehyde, acetaldehyde and benzene exposure was estimated and they varied from 7.8×10(-5) to 4.1×10(-4) for formaldehyde, from 8.6×10(-6) to 3.5×10(-5) for acetaldehyde and from 2.0×10(-6) to 1.5×10(-5) for benzene. For formaldehyde, the attributed risk in most sampled homes was two orders of magnitude higher than the one (10(-6)) proposed as acceptable by risk management bodies.

MATERIALIEN
Produktnummer
Marke
Produktbeschreibung

Sigma-Aldrich
Toluol, anhydrous, 99.8%
radiello Kartuschen-Adsorbenzien, for sampling BTEX and VOCs (CS2 Desorption), matrix SS net (100 mesh, 5.8 mm diam.), activated with activated charcoal (30-50 mesh), pk of 20
Sigma-Aldrich
Styrol, ReagentPlus®, contains 4-tert-butylcatechol as stabilizer, ≥99%
Sigma-Aldrich
Dodecan, anhydrous, ≥99%
Sigma-Aldrich
1-Butanol, for molecular biology, ≥99%
Sigma-Aldrich
Undecan, ≥99%
Sigma-Aldrich
Heptan, anhydrous, 99%
radiello Dreieckige Trägerplatte, pk of 20
Sigma-Aldrich
1,2,4-Trimethylbenzol, 98%
Sigma-Aldrich
1-Butanol, anhydrous, 99.8%
Sigma-Aldrich
Oktan, anhydrous, ≥99%
Sigma-Aldrich
Pentan, anhydrous, ≥99%
radiello Diffusionskörper, white, configured for general use, pk of 20
radiello Kartuschen-Adsorbenzien, for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20
Sigma-Aldrich
p-Xylen, anhydrous, ≥99%
Sigma-Aldrich
Decan, ≥95%
radiello Kartuschen-Adsorbenzien, for sampling Ammonia (NH3), matrix microporous PE impregnated with phosphoric acid, pk of 20
Sigma-Aldrich
Ethylbenzol, anhydrous, 99.8%
Sigma-Aldrich
Kohlenstoffdisulfid, anhydrous, ≥99%
Sigma-Aldrich
Butylalkohol, natural, ≥99.5%, FCC, FG
Sigma-Aldrich
Undecan, ≥99%
radiello Diffusionskörper, yellow, configured for reduced sampling rates, pk of 20
Sigma-Aldrich
o-Xylen, anhydrous, 97%
Sigma-Aldrich
Decan, anhydrous, ≥99%
radiello Kartuschen-Adsorbenzien, for sampling BTEX and VOCs (thermal desorption), matrix SS net (3 x 8 μm, 4.8 mm diam.), Carbograph, pk of 20
radiello Diffusionskörper, blue, configured for sampling light sensitive compounds, pk of 20
Sigma-Aldrich
Oktan, electronic grade, ≥99.999% metals basis, ≥99% (CP)
Sigma-Aldrich
Nonan, anhydrous, ≥99%
radiello Freiluft-Schutzvorrichtung, pk of 10
Supelco
radiello Methylenblau-Kalibrierstandard für H2S (Schwefelwasserstoff), pkg of 100 mL