Direkt zum Inhalt
Merck

MHS16

Sigma-Aldrich

Mayers Hämatoxylin-Lösung

Synonym(e):

(6aS,11bR)-7,11b-Dihydroindeno[2,1-c]chromen-3,4,6a,9,10(6H)-pentol, Hämatoxylin nach Delafield, Progressive Färbungen

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise

Größe auswählen

500 ML
€ 65,90

€ 65,90


Voraussichtliches Versanddatum23. März 2025


Bulk-Bestellung anfordern

Größe auswählen

Ansicht ändern
500 ML
€ 65,90

About This Item

MDL-Nummer:
UNSPSC-Code:
41116124
PubChem Substanz-ID:
NACRES:
NA.47

€ 65,90


Voraussichtliches Versanddatum23. März 2025


Bulk-Bestellung anfordern

Form

solution

Qualitätsniveau

Haltbarkeit

Expiry date on the label.

IVD

for in vitro diagnostic use

Konzentration

1 g/L

Methode(n)

microbe id | staining: suitable

pH-Wert

2.4 (25 °C)

Anwendung(en)

hematology
histology

Lagertemp.

room temp

SMILES String

Oc1cc2C[C@@]3(O)COc4c(O)c(O)ccc4[C@H]3c2cc1O

InChI

1S/C16H14O6/c17-10-2-1-8-13-9-4-12(19)11(18)3-7(9)5-16(13,21)6-22-15(8)14(10)20/h1-4,13,17-21H,5-6H2/t13-,16+/m0/s1

InChIKey

WZUVPPKBWHMQCE-XJKSGUPXSA-N

Suchen Sie nach ähnlichen Produkten? Aufrufen Leitfaden zum Produktvergleich

Allgemeine Beschreibung

Wird als Gegenfärbung in Verfahren wie Immunhistochemie oder Lasermikrodissektion verwendet.

Anwendung

Allzweck-Nuklearfärbung, progressive Art. Zur Verwendung bei Hämatoxylin-Eosin-Färbeverfahren.

Sonstige Hinweise

1 g/L zertifiziertes Hämatoxylin

Lagerklassenschlüssel

12 - Non Combustible Liquids

WGK

WGK 2

Flammpunkt (°F)

Not applicable

Flammpunkt (°C)

Not applicable


Hier finden Sie alle aktuellen Versionen:

Analysenzertifikate (COA)

Lot/Batch Number

Die passende Version wird nicht angezeigt?

Wenn Sie eine bestimmte Version benötigen, können Sie anhand der Lot- oder Chargennummer nach einem spezifischen Zertifikat suchen.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Markus Høybye Bosteen et al.
Atherosclerosis, 265, 93-101 (2017-09-04)
Chronic kidney disease is characterized by uremia and causes premature death, partly due to accelerated atherosclerosis. Apolipoprotein (apo) M is a plasma carrier protein for the lipid sphingosine-1-phosphate (S1P). The Apom-S1P complex associates with HDL, and may contribute to its
Max H Kushner et al.
EMBO reports, 21(1), e48741-e48741 (2019-12-04)
Transcription factors critical for the transition of normal breast epithelium to ductal carcinoma in situ (DCIS) and invasive breast cancer are not clearly defined. Here, we report that the expression of a subset of YAP-activated and YAP-repressed genes in normal mammary
Shyambabu Chaurasiya et al.
Cancer gene therapy, 27(3-4), 125-135 (2019-06-19)
Oncolytic viruses have shown excellent safety profiles in preclinical and clinical studies; however, in most cases therapeutic benefits have been modest. We have previously reported the generation of a chimeric poxvirus (CF33), with significantly improved oncolytic characteristics, through chimerization among
Hanna Kalamarz-Kubiak et al.
Biology open, 6(10), 1493-1501 (2017-09-02)
In this
Franziska Roth-Walter et al.
Scientific reports, 7, 45067-45067 (2017-03-24)
Acrolein, a highly reactive unsaturated aldehyde, is generated in large amounts during smoking and is best known for its genotoxic capacity. Here, we aimed to assess whether acrolein at concentrations relevant for smokers may also exert immunomodulatory effects that could

Verwandter Inhalt

Learn about the criticality of biological tissue staining for research and clinical pathology using standard and special stains and dyes.

Informationen zur wichtigen Bedeutung der Färbung biologischer Gewebe für die Forschung und klinische Pathologie unter Anwendung von Standardfärbungen und spezieller Färbemittel und Farbstoffe.

Questions

1–9 of 9 Questions  
  1. Is there an alternative product available for the MHS series of Mayers Hematoxylin solutions?

    1 answer
    1. The Mayers Hematoxylin available is the MHS series of hematoxylin solutions, comeS in various sizes from 100ml to 4L. These solutions are all formulated with chloral hydrate and no alcohol. There is also a Mayers Hemalum solution available as product number 109249, which is formulated with ethylene glycol in place of chloral hydrate. Additionally, there is an Acid Hematoxylin formulated with chloral hydrate, with catalog number 2852-100ml.

      Helpful?

  2. What would be the best solution to dilute product MHS16 to a 50% concentration?

    1 answer
    1. Aluminum-based hematoxylin solutions, including Mayers Hematoxylin, should never be diluted before use. Mayers Hematoxylin solution is ready to use as it comes from the bottle. The issue with diluting aluminum-based hematoxylins is that while the hematoxylin strength is diluted, so is the aluminum concentration. Mayers hematoxylin is a progressive hematoxylin, formulated with enough aluminum to prevent the hematoxylin from nonspecifically binding with the cytoplasm. Diluting the aluminum may lead to staining of the cytoplasm by the hematoxylin. As Mayers Hematoxylin has one of the lower hematoxylin concentrations among popular hematoxylin formulations, the best solution is to simply reduce the amount of time the tissues are stained in the Mayers Hematoxylin.

      Helpful?

  3. What is the recommended bluing agent for MHS16? Also, what is the recommended range of incubation time for using MHS16?

    1 answer
    1. The protocol for use simply states to blue in running tap water or a dilute alkaline solution. Warm tap water will be slightly more alkaline than cold tap water. Opt to use dilute alkaline solutions if the pH of tap water tends towards the acidic side, as this could cause issues with the tissues bluing quickly and properly. Among these solutions are saturated lithium carbonate solutions or 15 grams per liter of sodium bicarbonate, which can produce a slightly alkaline solution. Another option is Scott's Tap Water Substitute (catalog number S5134). Reagent or ACS grade lithium carbonate and sodium bicarbonate are suitable for use. Bluing with Scott's Tap Water Substitute produced the most stable stained nuclei. As for the recommended staining time, it is 15 minutes. However, Mayers Hematoxylin is a progressive hematoxylin, so if the nuclear staining is not intense enough, the staining time can be increased. Extending the staining time past 15 minutes should not result in overstaining of the cytoplasm, as Mayers Hematoxylin is formulated to prevent this.

      Helpful?

  4. There are several Mayer's Hematoxylins listed on the website, beginning with the letters MHS.  What are the differences?

    1 answer
    1. Products MHS1, MHS16, MHS32, MHS80 and MHS128 are in fact the same product. In this case a unique product number was assigned to each package size. Other than the package size, there are no differences in formulation or use.

      Helpful?

  5. Is chloral hydrate used in the preparation of Mayer's Hematoxylin?  Does this mean the solution is controlled as a DEA Schedule IV product?

    1 answer
    1. Yes, chloral hydrate is included in the formulation. No, the solution is not controlled as a DEA Schedule IV product. Once the choral hydrate is mixed with the remaining chemicals, it is impossible to obtain the chloral hydrate in a purified form.

      Helpful?

  6. The website states that Mayer's Hematoxylin solution is a progressive type hematoxylin. What is a progressive type hematoxylin?

    1 answer
    1. Hematoxylin solutions are generally classified as either progressive or regressive. Progressive formulations will stain only the nucleus. No staining should occur within the cytoplasm. Regressive hematoxylins have higher dye contents and if used for sufficient periods of time will overstain both the nucleus and the cytoplasm. Acid differentiation is required to remove the excessive stain from the cytoplasm and nucleus. This differentiation take practice to master. Too much or too little stain can be removed during differentiation, resulting in poorly stained slides. For users lacking extensive experience with the Hematoxylin and Eosin staining procedure,  progressive hematoxylin formulations are often the better choice.

      Helpful?

  7. What is the Department of Transportation shipping information for this product?

    1 answer
    1. Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.

      Helpful?

  8. There is also a product listed on the website as Hematoxylin Solution According to Mayer. What is the difference between product 51275 and the various Mayer's Hematoxylin solutions?

    1 answer
    1. The basic formulations are the same. Both include chloral hydrate, although some of the concentrations could vary slightly. Product 51275 is not intended for In Vitro Diagnostic Use. Product 51275 is not CE Marked. The various Mayer's Hematoyxlin solutions are intended For In Vitro Diagnostic Use and are also CE Marked. Product inserts are available for various languages.

      Helpful?

  9. The slides were stained with Mayer's Hematoxylin but the nuclei are not blue. Why?

    1 answer
    1. The nuclei will originally appear as the same color as the solution. Only after the slides have been "blued" will the nuclei appear blue. The pH of the solution is acidic. This acidic pH promotes specific staining. However the slides must be washed in an neutral or alkaline solution for the color to shift to blue. Prolonged warm water washes in tap water are often sufficient for the bluing to occur. To shorten the time spent in washing, various bluing agents are often used to shorten the blueing process. Scott's Tap Water Substitute (Product No. S5134) is one such blueing agent.

      Helpful?

Reviews

No rating value

Active Filters

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.