Direkt zum Inhalt
Merck

P4869

Sigma-Aldrich

Molybdatophosphorsäure -Lösung

spray reagent, 10% in ethanol

Synonym(e):

Molybdatophosphorsäure

Anmeldenzur Ansicht organisationsspezifischer und vertraglich vereinbarter Preise


About This Item

Lineare Formel:
H3[P(Mo3O10)4]
CAS-Nummer:
Molekulargewicht:
1825.25
MDL-Nummer:
UNSPSC-Code:
12352301
PubChem Substanz-ID:
NACRES:
NA.22

Eignung der Reaktion

reagent type: oxidant

Verpackung

pkg of 100 mL

Konzentration

10% in ethanol

Lagertemp.

2-8°C

SMILES String

O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.O=[Mo](=O)=O.OP(O)(O)=O

InChI

1S/12Mo.H3O4P.36O/c;;;;;;;;;;;;1-5(2,3)4;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;/h;;;;;;;;;;;;(H3,1,2,3,4);;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;

InChIKey

DHRLEVQXOMLTIM-UHFFFAOYSA-N

Anwendung

Zur Detektion von Lipiden, Steroiden, Lactonen, Ketosäuren, Hydroxysäuren, ungesättigten Fetsäuren und phenolischen Verbindungen.

Sonstige Hinweise

10% Phosphomolybdänsäure in Ethanol

Signalwort

Danger

Gefahreneinstufungen

Eye Dam. 1 - Flam. Liq. 2 - Ox. Liq. 3 - Skin Corr. 1B

Lagerklassenschlüssel

5.1B - Oxidizing hazardous materials

WGK

WGK 3

Flammpunkt (°F)

55.0 °F - closed cup

Flammpunkt (°C)

12.8 °C - closed cup

Persönliche Schutzausrüstung

Faceshields, Gloves, Goggles, type ABEK (EN14387) respirator filter


Analysenzertifikate (COA)

Suchen Sie nach Analysenzertifikate (COA), indem Sie die Lot-/Chargennummer des Produkts eingeben. Lot- und Chargennummern sind auf dem Produktetikett hinter den Wörtern ‘Lot’ oder ‘Batch’ (Lot oder Charge) zu finden.

Besitzen Sie dieses Produkt bereits?

In der Dokumentenbibliothek finden Sie die Dokumentation zu den Produkten, die Sie kürzlich erworben haben.

Die Dokumentenbibliothek aufrufen

Almino Afonso de O Paiva et al.
International immunopharmacology, 11(9), 1241-1250 (2011-04-21)
This study analyzes the action of sulfated polysaccharides, fucans, from algae Lobophora variegata on zymosan-induced arthritis in rats. Groups of fucans, obtained after acetone fractionation (0.3-2.0 volumes), were denominated F0.3, F0.5, F0.8, F1, F1.5, and F2. The results that F1
Zhiming Cui et al.
Physical chemistry chemical physics : PCCP, 13(36), 16349-16357 (2011-08-16)
A simple self-assembly approach has been developed to functionalize carbon nanotubes (CNTs) with chitosan (CS) and heteropolyacids (HPAs) of phosphomolybdic acid (H(3)PMo(12)O(40), HPMo) and phosphotungstic acid (H(3)PW(12)O(40), HPW). The non-covalent functionalization method, which introduces homogenous surface functional groups with no
Maher Mahmoud El-Hashash et al.
Acta pharmaceutica (Zagreb, Croatia), 60(3), 361-367 (2010-12-08)
In the present study, antioxidant activity of methanolic extracts of the leaves of seven Egyptian Cassia species was investigated using two methods, the phosphomolyb-date method and 1,1 diphenyl-2-picrylhydrazyl radical (DPPH) scavenging activity method.· The results revealed that C. glauca is
Dawei Fan et al.
Journal of colloid and interface science, 351(1), 151-155 (2010-08-19)
Hybrid films composed of oppositely charged Keggin-type 12-molybdophosphoric acid H(3)PMo(12)O(40).nH(2)O (PMo(12)) and water-soluble cationic meso-tetra (N-methyl-4-pyridyl) porphinetetratosylate (TMPyP) were fabricated onto silicon and ITO substrates by a layer-by-layer (LbL) self-assembly technique. The LbL films were characterized by UV-vis spectroscopy, X-ray
Rubel Chakravarty et al.
Journal of chromatography. A, 1220, 82-91 (2011-12-27)
Barium-137m availed from a (137)Cs/(137m)Ba generator is an attractive industrial radiotracer for liquid flow rate measurement owing to its short half-life (T(1/2)=2.5 min) and emission of highly energetic gamma radiation (E(γ)=661.7 keV). Ammonium molybdophosphate (AMP) impregnated alumina microspheres (AMP-Al(2)O(3)), an

Unser Team von Wissenschaftlern verfügt über Erfahrung in allen Forschungsbereichen einschließlich Life Science, Materialwissenschaften, chemischer Synthese, Chromatographie, Analytik und vielen mehr..

Setzen Sie sich mit dem technischen Dienst in Verbindung.