1.14683
Residual Hardness Test, photometric
photometric, 0.50-5.00 mg/L (Ca), water hardness 0.070-0.700 °d, water hardness 0.087-0.874 °e, water hardness 0.12-1.25 °f, 0.70-7.00 mg/L (CaO), 1.2-12.5 mg/L (CaCO3), Spectroquant®
About This Item
Polecane produkty
product name
Residual Hardness Cell Test, photometric, 0.50-5.00 mg/L (Ca), water hardness 0.070-0.700 °d, water hardness 0.087-0.874 °e, water hardness 0.12-1.25 °f, 0.70-7.00 mg/L (CaO), 1.2-12.5 mg/L (CaCO3), Spectroquant®
linia produktu
Spectroquant®
Poziom jakości
zastosowanie
sufficient for 25 tests
specyficzne anality
calcium
zakres pomiaru
0.50-5.00 mg/L (Ca)
0.70-7.00 mg/L (CaO)
1.2-12.5 mg/L (CaCO3)
water hardness measuring range
0.070-0.700 °d
0.087-0.874 °e
0.12-1.25 °f
metody
photometry: suitable
kompatybilność
for use with Spectroquant® Move 100
for use with Spectroquant® Nova 60 A
for use with Spectroquant® Prove 100
for use with Spectroquant® Prove 300
for use with Spectroquant® Prove 600
metoda wykrywania
photometric (Phthalein complexone)
temp. przechowywania
2-8°C
Opis ogólny
This Spectroquant® Residual Hardness Cell Test specially designed for the accurate analysis of low values of hardness in highly purified water samples. The hardness of a given sample is due to its content of salts of the alkaline earth metals calcium, magnesium, strontium, and barium (“hardening constituents”). Since strontium and barium are generally present in waters only in traces, the hardness is defined as the content in a water of calcium ions, Ca2+, and magnesium ions, Mg2+ (“hardness ions”).
Method applied: In alkaline solution calcium and magnesium ions form with phthalein purple a violet dye that is determined photometrically.
The Spectroquant® Cell Tests come with prefilled 16 mm round cells and all the required reagents to perform the analysis according to the instruction leaflet provided.
All Spectroquant® Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.
Informacje prawne
Hasło ostrzegawcze
Warning
Zwroty wskazujące rodzaj zagrożenia
Zwroty wskazujące środki ostrożności
Klasyfikacja zagrożeń
Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2
Kod klasy składowania
8A - Combustible, corrosive hazardous materials
Klasa zagrożenia wodnego (WGK)
WGK 3
Certyfikaty analizy (CoA)
Poszukaj Certyfikaty analizy (CoA), wpisując numer partii/serii produktów. Numery serii i partii można znaleźć na etykiecie produktu po słowach „seria” lub „partia”.
Masz już ten produkt?
Dokumenty związane z niedawno zakupionymi produktami zostały zamieszczone w Bibliotece dokumentów.
Nasz zespół naukowców ma doświadczenie we wszystkich obszarach badań, w tym w naukach przyrodniczych, materiałoznawstwie, syntezie chemicznej, chromatografii, analityce i wielu innych dziedzinach.
Skontaktuj się z zespołem ds. pomocy technicznej