Functionally, WGA1 and WGA2 kits are identical. The only difference between the two kits is that WGA2 is supplied with the WGA polymerase.
¥84,750
出荷可能日2025年4月03日詳細
おすすめの製品
テクニック
whole genome amplification: suitable
輸送温度
wet ice
保管温度
−20°C
詳細
WGA Kit utilizes a proprietary technology based on random fragmentation of genomic DNA and conversion of the resulting small fragments to PCR-amplifiable library molecules flanked by universal priming sites. WGA is achieved by PCR amplification of the library molecules using universal oligonucleotide primers.
GenomePlex method allows the researcher to generate a representative, ~500-fold amplification of genomic DNA. The amplification yield is dependent on the purity and amount of starting material. This kit contains all the required reagents to perform library preparation and fragmentation.
アプリケーション
特徴および利点
- Higher yield from minimal template: Amplification of nanogram amounts (10ng) of genomic DNA to microgram yields (5-10 μg) in less than about three hours
- Nanograms of samples can be preserved at –20 °C for future use
- Choose from a variety of DNA sources: whole blood, buccal swab, blood card, plant, soil, and formalin-fixed paraffin-embedded tissue (FFPE)
- Compatible with a wide variety of downstream applications such as TaqMan® and BeadArray assays
- Universal primers
- Whole-genome representation with no detectable bias
- Increased accuracy in amplification produces no amplicon in the negative control reactions
その他情報
法的情報
推奨
保管分類コード
10 - Combustible liquids
WGK
WGK 3
引火点(°F)
Not applicable
引火点(℃)
Not applicable
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
毒物及び劇物取締法
キットコンポーネントの情報を参照してください
PRTR
キットコンポーネントの情報を参照してください
消防法
キットコンポーネントの情報を参照してください
労働安全衛生法名称等を表示すべき危険物及び有害物
キットコンポーネントの情報を参照してください
労働安全衛生法名称等を通知すべき危険物及び有害物
キットコンポーネントの情報を参照してください
カルタヘナ法
キットコンポーネントの情報を参照してください
Jan Code
キットコンポーネントの情報を参照してください
この製品を見ている人はこちらもチェック
資料
Whole genome amplification overcomes restrictions for single-cell genomic analyses with non-specific amplification.
プロトコル
Archived Formalin-fixed, Paraffin-embedded (FFPE) tissue samples are invaluable resources for profiling gene expression and studying a variety of diseases.
GenomePlex® amplification improves DNA yield from soil samples, ensuring downstream analysis reliability despite potential nuclease damage.
GenomePlex® Whole Genome Amplification efficiently extracts DNA from animal samples for genomic analysis.
Whole Genome Amplification products, including kits for DNA extraction, support various DNA sources.
関連コンテンツ
GenomePlex is a Whole Genome Amplification (WGA) method that allows the researcher to generate a representative, 500-fold amplification of genomic DNA
-
What is the major difference between WGA1 and WGA2 kits?
1 回答-
役に立ちましたか?
-
-
Can I use WGA1, GenomePlex® Amplification Kit to amplify DNA from a single cell?
1 回答-
Using this kit to amplify DNA from a single cell is not recommended. We recommend using the GenomePlex Single Cell WGA Kit (WGA4) for such application. WGA4 was developed for use with single cells and includes an optimized cell lysis protocol which has been incorporated into the fragmentation step.
役に立ちましたか?
-
-
If starting with fragmented DNA, what is the smallest size fragment which can be successfully amplified with WGA1, GenomePlex® Amplification Kit, and do I still need to do the fragmentation step?
1 回答-
The kit works best for fragments 400 bp and larger. When starting with fragmented DNA, we recommend: (1) skipping the fragmentation heat step, although the buffer should be added, and (2) increasing the PCR cycles from 14 to 20.
役に立ちましたか?
-
-
Can I amplify single stranded DNA with Product WGA, GenomePlex® Amplification Kit?
1 回答-
When starting with single stranded starting materials, we recommend (1) skipping the fragmentation heat step, although the buffer should be added and (2) increasing the PCR cycles from 14 to 20. Note that if the ssDNA is actually cDNA from polyadenylated RNA, the kit will likely not give good representation of the input material, as the poly(T) ends constitute a large, non-random fraction.
役に立ちましたか?
-
-
What is the major difference between WGA1 and WGA2?
1 回答-
Functionally WGA1 and WGA2 are identical. The only difference between the two kits is that WGA2 is supplied with the WGA polymerase.
役に立ちましたか?
-
-
What is the Department of Transportation shipping information for this product?
1 回答-
Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product.
役に立ちましたか?
-
-
Is the WGA1 GenomePlex® Amplicification Kit polymerase compatible with TA cloning?
1 回答-
WGA polymerase is compatible with TA cloning with the following alteration to the PCR step: Be sure to include a 7 to 30 minute extension at 72°C after the last cycle to ensure that all PCR products are full length and 3´ adenylated.
役に立ちましたか?
-
アクティブなフィルタ
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)